<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2 20190208//EN" "http://jats.nlm.nih.gov/publishing/1.2/JATS-journalpublishing1.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="1.2" xml:lang="en">
    <front>
        <journal-meta>
            <journal-id journal-id-type="pmc">F1000Research</journal-id>
            <journal-title-group>
                <journal-title>F1000Research</journal-title>
            </journal-title-group>
            <issn pub-type="epub">2046-1402</issn>
            <publisher>
                <publisher-name>F1000 Research Limited</publisher-name>
                <publisher-loc>London, UK</publisher-loc>
            </publisher>
        </journal-meta>
        <article-meta>
            <article-id pub-id-type="doi">10.12688/f1000research.73236.1</article-id>
            <article-categories>
                <subj-group subj-group-type="heading">
                    <subject>Research Article</subject>
                </subj-group>
                <subj-group>
                    <subject>Articles</subject>
                </subj-group>
            </article-categories>
            <title-group>
                <article-title>Enhancement of digitized X-ray films using Contrast-Limited Adaptive Histogram Equalization (CLAHE)</article-title>
                <fn-group content-type="pub-status">
                    <fn>
                        <p>[version 1; peer review: 1 approved, 1 approved with reservations]</p>
                    </fn>
                </fn-group>
            </title-group>
            <contrib-group>
                <contrib contrib-type="author" corresp="yes">
                    <name>
                        <surname>Mohd-Isa</surname>
                        <given-names>Wan-Noorshahida</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Conceptualization</role>
                    <role content-type="http://credit.niso.org/">Formal Analysis</role>
                    <role content-type="http://credit.niso.org/">Project Administration</role>
                    <role content-type="http://credit.niso.org/">Supervision</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Original Draft Preparation</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Review &amp; Editing</role>
                    <uri content-type="orcid">https://orcid.org/0000-0001-9060-0250</uri>
                    <xref ref-type="corresp" rid="c1">a</xref>
                    <xref ref-type="aff" rid="a1">1</xref>
                </contrib>
                <contrib contrib-type="author" corresp="no">
                    <name>
                        <surname>Joseph</surname>
                        <given-names>Joel</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Data Curation</role>
                    <role content-type="http://credit.niso.org/">Investigation</role>
                    <role content-type="http://credit.niso.org/">Methodology</role>
                    <xref ref-type="aff" rid="a1">1</xref>
                </contrib>
                <contrib contrib-type="author" corresp="no">
                    <name>
                        <surname>Hashim</surname>
                        <given-names>Noramiza</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Conceptualization</role>
                    <role content-type="http://credit.niso.org/">Project Administration</role>
                    <uri content-type="orcid">https://orcid.org/0000-0001-9838-2892</uri>
                    <xref ref-type="aff" rid="a1">1</xref>
                </contrib>
                <contrib contrib-type="author" corresp="no">
                    <name>
                        <surname>Salih</surname>
                        <given-names>Nbhan</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Formal Analysis</role>
                    <role content-type="http://credit.niso.org/">Validation</role>
                    <xref ref-type="aff" rid="a1">1</xref>
                </contrib>
                <aff id="a1">
                    <label>1</label>Faculty of Computing and Informatics, Multimedia University, Cyberjaya, Selangor, 63100, Malaysia</aff>
            </contrib-group>
            <author-notes>
                <corresp id="c1">
                    <label>a</label>
                    <email xlink:href="mailto:wan.noorshahida.isa@mmu.edu.my">wan.noorshahida.isa@mmu.edu.my</email>
                </corresp>
                <fn fn-type="conflict">
                    <p>No competing interests were disclosed.</p>
                </fn>
            </author-notes>
            <pub-date pub-type="epub">
                <day>15</day>
                <month>10</month>
                <year>2021</year>
            </pub-date>
            <pub-date pub-type="collection">
                <year>2021</year>
            </pub-date>
            <volume>10</volume>
            <elocation-id>1051</elocation-id>
            <history>
                <date date-type="accepted">
                    <day>6</day>
                    <month>10</month>
                    <year>2021</year>
                </date>
            </history>
            <permissions>
                <copyright-statement>Copyright: &#x00a9; 2021 Mohd-Isa WN et al.</copyright-statement>
                <copyright-year>2021</copyright-year>
                <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
                    <license-p>This is an open access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
                </license>
            </permissions>
            <self-uri content-type="pdf" xlink:href="https://f1000research.com/articles/10-1051/pdf"/>
            <abstract>
                <p>
                    <bold>Background</bold>: Rural clinics still have X-ray facilities that produce physical films, which are sent to the nearest hospital for evaluation.&#x00a0; Purchasing digitalization facilities is costly, thus, sending digitized films to the radiologist may be a solution.&#x00a0; This can be achieved via digital photo capture.&#x00a0; However, there can be different output resolutions that may not be optimized for online diagnosis.&#x00a0; This paper investigates if digitized X-ray films can be enhanced using image processing techniques of Contrast-Limited Adaptive Histogram Equalization (CLAHE), Normalized-CLAHE (N-CLAHE) and Min-Max Normalized-CLAHE (MMCLAHE).&#x00a0; &#x00a0;&#x00a0;&#x00a0;&#x00a0;&#x00a0;</p>
                <p>
                    <bold>Methods</bold>: We collected and digitized 21 X-ray films with low, medium, and high resolutions and implemented the CLAHE, N-CLAHE and MMCLAHE image enhancement. These methods introduced a limit to clip the histogram of image intensities so as to reduce any noise amplification before file compression with the Fast Fourier Transform (FFT) and Discrete Cosine Transform (DCT). &#x00a0;Quantitative metrics of the Peak Signal-to-Noise Ratio (PSNR) and Mean-Squared Error (MSE) were used to compare the accuracies between digitized and processed X-ray films.&#x00a0; A qualitative evaluation was performed by a medical practitioner to validate the accuracy of enhanced digitized X-ray.&#x00a0;</p>
                <p>
                    <bold>Results</bold>: It had been found that both CLAHE and MMCLAHE provided good average PSNR values of 31dB - 32dB and produced low MSE values compared to N-CLAHE.&#x00a0; The results of qualitative evaluation attained 89.9% correct diagnosis on nine randomly selected images.&#x00a0; Generally, the evaluation indicated that the results fulfill the acceptable criteria for further evaluation and there seemed to be no pathological differences observed.</p>
                <p>
                    <bold>Conclusion</bold>: This paper presented a proof of concept on an implementation of the CLAHE technique and its variations on digitized X-ray films.&#x00a0; This paper had shown potential improvements with the proposed enhancement methods that may contribute to an increase efficiency in healthcare processes at rural clinics.</p>
            </abstract>
            <kwd-group kwd-group-type="author">
                <kwd>digital imaging</kwd>
                <kwd>image enhancement</kwd>
                <kwd>image compression</kwd>
                <kwd>histogram equalization</kwd>
                <kwd>telemedicine</kwd>
            </kwd-group>
            <funding-group>
                <funding-statement>The author(s) declared that no grants were involved in supporting this work.</funding-statement>
            </funding-group>
        </article-meta>
    </front>
    <body>
        <sec id="sec1" sec-type="intro">
            <title>Introduction</title>
            <p>The pandemic situation has accelerated digitalization to many countries. However, people living in rural areas are having an inconvenience to access medical technologies due to unavailability of specialists and also shortage of medical equipments.
                <sup>
                    <xref ref-type="bibr" rid="ref1">1</xref>
                </sup> In Malaysia rural clinics, for example, there are still X-ray facilities that produce physical X-ray films. The films are then sent using courier services to the nearest available hospital for diagnosis by radiologists, making the whole process becomes inefficient. Moreover, purchasing new digital X-ray facilities for rural clinics may not be cost beneficial since the population numbers are low.</p>
            <p>Digital technology has seen growth that leads to telemedicine.
                <sup>
                    <xref ref-type="bibr" rid="ref2">2</xref>
                </sup>
                <sup>&#x2013;</sup>
                <sup>
                    <xref ref-type="bibr" rid="ref4">4</xref>
                </sup> Telemedicine makes use of communication technology in healthcare and can be cost effective. However, telemedicine is not commonly practiced in Malaysia
                <sup>
                    <xref ref-type="bibr" rid="ref5">5</xref>
                </sup> despite its potential to address healthcare shortcomings in the rural areas. In this paper, we propose a proof of concept work to digitalize physical X-ray films via digital photo capture so that their digital versions can be sent via email or cloud for evaluation by a radiologist elsewhere. This may improve efficiency in remote diagnosis as well as reducing physical storage.
                <sup>
                    <xref ref-type="bibr" rid="ref6">6</xref>
                </sup>
            </p>
            <p>A study by
                <sup>
                    <xref ref-type="bibr" rid="ref1">1</xref>
                </sup> had described a simple implementation of 70 digitized chest X-ray films using a digital camera with an application of lossy compression technique. The digitized images had been shown in random order to two radiologists for diagnosis at 8 weeks after image capture. Then, lossy compression of different percentages were applied. The compressed images were again shown to the same radiologists in a random order for diagnosis at 8 weeks after the compression. The study achieved a mean percentage of 90% correct diagnosis with compression levels up to 20%. But with a compression of 40% and 50%, the correct percentages were 84% and 80%, respectively.</p>
            <p>A similar study by
                <sup>
                    <xref ref-type="bibr" rid="ref7">7</xref>
                </sup> used an 8-megapixel smartphone on 44 X-ray films consisting of 16 chest and 28 musculo-skeletal. The digitize X-ray films were shown in random order to two radiologists for diagnosis through a LCD cellphone. The accuracy of diagnosis was reported as high. Also it was reported that a diagnosis was difficult when involving uncommon and difficult pathology cases.</p>
            <p>These studies purely implemented digital photo capture of X-ray films and performed diagnosis without requiring online transmission. For sending images over the network, small file size with good resolution is best. However, there can be different resolutions due to differences in digital imaging software and hardware, hence, producing different qualities of digital X-ray films.
                <sup>
                    <xref ref-type="bibr" rid="ref8">8</xref>
                </sup> These variations open an opportunity to explore image enhancement techniques on images of digitized X-ray films.
                <sup>
                    <xref ref-type="bibr" rid="ref9">9</xref>
                </sup>
                <sup>&#x2013;</sup>
                <sup>
                    <xref ref-type="bibr" rid="ref15">15</xref>
                </sup> In this paper, we investigate the use of CLAHE image processing techniques as a proof of concept and we validate the output via quantitative metrics and qualitative evaluation by a medical practitioner.</p>
        </sec>
        <sec id="sec2" sec-type="methods">
            <title>Methods</title>
            <p>
                <xref ref-type="fig" rid="f1">Figure 1</xref> shows the flow of our proposed methodology, which includes, data collection and digitalization, image enhancement and compression, and evaluation. These would be discussed in the preceding sections.</p>
            <fig fig-type="figure" id="f1" orientation="portrait" position="float">
                <label>Figure 1. </label>
                <caption>
                    <title>The general processes involved in this research.</title>
                </caption>
                <graphic id="gr1" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/76876/9eab63fb-1c69-42de-9cd4-9dc6635bf61c_figure1.gif"/>
            </fig>
            <sec id="sec3">
                <title>Ethical statement</title>
                <p>This research project had received approval from the Multimedia University Research Ethics Committee (EA2242021).</p>
            </sec>
            <sec id="sec4">
                <title>Data collection and digitalization</title>
                <p>We selected 21 upright chest X-ray images consisting of multiple abnormal diagnoses from multiple online databases.
                    <sup>
                        <xref ref-type="bibr" rid="ref16">16</xref>
                    </sup> Then, we printed these online sources to obtain the physical chest X-ray films (CXR). After that, the CXR were captured using an Apple iPhone XS Max. To alter the image resolutions, the images were taken using a third-party application, DSLR Camera.
                    <sup>
                        <xref ref-type="bibr" rid="ref17">17</xref>
                    </sup> An X-ray illuminator (Victor Steel VS148-A) was used as shown in 
                    <xref ref-type="fig" rid="f2">Figure 2</xref>.</p>
                <fig fig-type="figure" id="f2" orientation="portrait" position="float">
                    <label>Figure 2. </label>
                    <caption>
                        <title>The camera and illuminator (view box) setup for digitalization of physical X-ray films.</title>
                    </caption>
                    <graphic id="gr2" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/76876/9eab63fb-1c69-42de-9cd4-9dc6635bf61c_figure2.gif"/>
                </fig>
                <p>The setup in 
                    <xref ref-type="fig" rid="f2">Figure 2</xref> was done in a well-lit surrounding. A view box was placed on a flat surface approximately 30 cm away from a tripod mounted with a smartphone. A CXR was clipped to the view box in a side-view position with the illuminated area placed facing the smartphone. The position of the tripod head was adjusted to ensure the CXR filled the phone display and the personal details at the corner side were not in view. The flashlight setting was turned off to avoid reflections. The ISO speed was fixed to ISO-24 with an exposure time fixed to 1/100 seconds. Images were taken at 
                    <italic toggle="yes">High</italic>, 
                    <italic toggle="yes">Medium</italic>, and 
                    <italic toggle="yes">Low</italic> resolutions for a total of 63 digitized CXR. These images were stored as a JPEG format and unnecessary details were cropped using Windows 10 Photos application.</p>
            </sec>
            <sec id="sec5">
                <title>Image enhancement</title>
                <p>Histogram Equalization (HE) is the commonly used method for image enhancement. In HE the contrast of an image is enhanced by modifying the distribution of pixel intensities. By distributing pixel intensities equally to each histogram, a global equalization is achieved. Thus, HE tends to over-enhance parts of an image that adds unnecessary artifacts and may increase image noise.
                    <sup>
                        <xref ref-type="bibr" rid="ref11">11</xref>
                    </sup>
                </p>
                <p>Adaptive Histogram Equalization (AHE) is an improvement of HE. AHE improves local contrast by dividing an image into blocks and applying computations to every block.
                    <sup>
                        <xref ref-type="bibr" rid="ref11">11</xref>
                    </sup> Bilinear interpolation is used to combine all blocks into one image. A study conducted by
                    <sup>
                        <xref ref-type="bibr" rid="ref10">10</xref>
                    </sup> applied AHE on 50 microfocus X-ray images. It showed that 80% of these had significant increase in contrast and detailing. However, AHE had a slow processing speed and enhanced image noise.</p>
                <p>Contrast-Limited Adaptive Histogram Equalization (CLAHE) is an extension of AHE. Similar to AHE, CLAHE uses blocks in an image. The only difference is the addition of a contrast limit to reduce the noise amplification by clipping the histograms.
                    <sup>
                        <xref ref-type="bibr" rid="ref14">14</xref>
                    </sup> The limit is a predefined value prior to calculation of a Cumulative Distributive Function (CDF). Histograms that exceed the clipped value are redistributed evenly to other histograms instead of removal. A study by
                    <sup>
                        <xref ref-type="bibr" rid="ref9">9</xref>
                    </sup> found that images produced from CLAHE had higher pixel values than that of original images and had brought out more details and structure to the images. Both
                    <sup>
                        <xref ref-type="bibr" rid="ref9">9</xref>
                    </sup> and
                    <sup>
                        <xref ref-type="bibr" rid="ref14">14</xref>
                    </sup> had agreed that CLAHE was good at maintaining image brightness level.</p>
                <p>A study by
                    <sup>
                        <xref ref-type="bibr" rid="ref18">18</xref>
                    </sup> proposed Normalized-CLAHE (N-CLAHE) that involved both Normalization function and CLAHE. In this method, a Logarithmic-Normalization function calculated output pixel intensity values by applying a Logarithmic function to input pixel intensity values. Normalization corrected the global intensity value before CLAHE computed the local contrast enhancement&#x00a0;value.</p>
                <p>The Min-Max Normalized-CLAHE (MMCLAHE) is a method that uses Min-Max values for the pixel intensity values. The pixel intensity is calculated using a ratio between new maximum (
                    <italic toggle="yes">newMax</italic>) and new minimum (
                    <italic toggle="yes">newMin</italic>) intensities to previous maximum (
                    <italic toggle="yes">Max</italic>) and previous minimum (
                    <italic toggle="yes">Min</italic>) intensity values.</p>
            </sec>
            <sec id="sec6">
                <title>Image compression</title>
                <p>Image compression is a process to reduce large-sized images into smaller-sized images without degrading the image quality. In this work, it is required to compress the digitized CXR since these need to be sent to the specialists using a low or moderate network bandwidth. Compression works by reducing the number of bits to represent an image. It has three types, lossless, lossy and hybrid.
                    <sup>
                        <xref ref-type="bibr" rid="ref19">19</xref>
                    </sup> A hybrid compression combines both lossless and lossy based on region of interest (ROI) and non-ROI of images.
                    <sup>
                        <xref ref-type="bibr" rid="ref20">20</xref>
                    </sup> However, in the absence of subject experts, the ROI could not be determined
                    <sup>
                        <xref ref-type="bibr" rid="ref21">21</xref>
                    </sup>
                    <sup>&#x2013;</sup>
                    <sup>
                        <xref ref-type="bibr" rid="ref23">23</xref>
                    </sup> as in our work.</p>
                <p>A lossless compression produces high-fidelity reproduction of images but may tend to have large file sizes. On the other hand, lossy compression produces good compression for use in telemedicine that suits rural areas with limited internet&#x00a0;connectivity. Thus, in this research, standard lossy image compression techniques such as the Fast Fourier Transform (FFT) and Discrete Cosine Transform (DCT) are used.
                    <sup>
                        <xref ref-type="bibr" rid="ref24">24</xref>
                    </sup>
                </p>
            </sec>
            <sec id="sec7">
                <title>Quantitative evaluation metrics</title>
                <p>The Peak Signal-to-Noise Ratio (PSNR) and Mean-Squared Error (MSE) are our quality metrics for comparing the before and after processing of the digitized CXR. A higher PSNR value means better quality of the compressed image. A lower MSE value means less errors contain in the image.</p>
            </sec>
            <sec id="sec8">
                <title>Qualitative evaluation procedure</title>
                <p>To validate the diagnosis of the digitized CXR, we invited a medical practitioner to perform a blind evaluation. A randomly selected processed CXR with specific diagnosis were sent to the evaluator. The evaluator was asked to confirm the diagnosis by answering a series of &#x201c;yes/no&#x201d; questions and the responses were recorded.</p>
            </sec>
        </sec>
        <sec id="sec9" sec-type="results|discussion">
            <title>Results and discussion</title>
            <p>
                <xref ref-type="table" rid="T1">Table 1</xref> shows the average PSNR and MSE values for each image enhancement and image compression pairs. From this table the results show that CLAHE-DCT gave the lowest average MSE of 35.59 and the highest average PSNR values of 32.85dB compared to other methods. Nevertheless, CLAHE-FFT, MMCLAHE-DCT and MMCLAHE-FFT also attained comparable good values of PSNR at 32.67dB, 31.98dB, and 31.80dB, respectively. Also CLAHE-FFT produced comparable low average MSE results at 36.96. Both MMCLAHE-DCT and MMCLAHE-FFT attained MSE values of 57.16 and 58.71, respectively.</p>
            <table-wrap id="T1" orientation="portrait" position="float">
                <label>Table 1. </label>
                <caption>
                    <title>Average MSE and PSNR values for each image enhancement and compression techniques.</title>
                </caption>
                <table content-type="article-table" frame="hsides">
                    <thead>
                        <tr>
                            <th align="left" colspan="1" rowspan="1" valign="top">Image enhancement techniques</th>
                            <th align="left" colspan="1" rowspan="1" valign="top">Image compression techniques</th>
                            <th align="left" colspan="1" rowspan="1" valign="top">Average MSE</th>
                            <th align="left" colspan="1" rowspan="1" valign="top">Average PSNR (dB)</th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">CLAHE</td>
                            <td align="left" colspan="1" rowspan="3" valign="middle">FFT</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">36.96</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">32.67</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">MMCLAHE</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">58.71</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">31.81</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">N-CLAHE</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">6533.91</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">10.01</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">CLAHE</td>
                            <td align="left" colspan="1" rowspan="3" valign="middle">DCT</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">35.59</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">32.85</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">MMCLAHE</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">57.16</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">31.98</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">N-CLAHE</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">6533.09</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">10.01</td>
                        </tr>
                    </tbody>
                </table>
            </table-wrap>
            <p>
                <xref ref-type="fig" rid="f3">Figure 3</xref> shows samples of processed CXR with a pneumothorax at 
                <italic toggle="yes">High</italic> resolution level. They are labelled as A, B, C, D, E, F from top-left to bottom-right. Samples of processed CXR for CLAHE and MMCLAHE are in 
                <xref ref-type="fig" rid="f3">Figure 3</xref> (A, B, C, and D).</p>
            <fig fig-type="figure" id="f3" orientation="portrait" position="float">
                <label>Figure 3. </label>
                <caption>
                    <title>Quality evaluation images by medical practitioner. From left-top to right-bottom, Image A, B, C, D, E, F.</title>
                </caption>
                <graphic id="gr3" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/76876/9eab63fb-1c69-42de-9cd4-9dc6635bf61c_figure3.gif"/>
            </fig>
            <p>On the contrary, both N-CLAHE FFT and N-CLAHE DCT attained the highest MSE and the lowest PSNR values at about 6533 and 10dB, respectively. It can be seen in 
                <xref ref-type="fig" rid="f3">Figure 3</xref> (E and F) that the N-CLAHE method had produced an overexposure on the digitized CXR.</p>
            <p>For qualitative evaluation, samples of 
                <xref ref-type="fig" rid="f3">Figure 3</xref> were presented to the medical practitioner. Generally, the practitioner was extremely satisfied with the quality of the digitized and processed CXR. Images C and D (using MMCLAHE) were said to be better than Images A and B (using CLAHE). Images E and F (using N-CLAHE) were the worst among all due to overexposure.</p>
            <p>
                <xref ref-type="table" rid="T2">Table 2</xref> shows the results of blind qualitative evaluation where nine images were randomly selected for diagnosis. All diagnosis of the presented digitized CXR had managed to be identified without any difficulties except for Image 7. The true diagnosis for Image 7 was 
                <italic toggle="yes">Normal.</italic> However, the diagnosis reported that there might be some abnormalities present even though Image 7 was a 
                <italic toggle="yes">High</italic> resolution MMCLAHE-FFT enhanced image. Thus, a simple accuracy attained by the qualitative evaluation is 89.9%, which is comparable to the work of Refs. 
                <xref ref-type="bibr" rid="ref1">1</xref> and 
                <xref ref-type="bibr" rid="ref7">7</xref>.</p>
            <table-wrap id="T2" orientation="portrait" position="float">
                <label>Table 2. </label>
                <caption>
                    <title>Diagnoses results by medical practitioner.</title>
                </caption>
                <table content-type="article-table" frame="hsides">
                    <thead>
                        <tr>
                            <th align="left" colspan="1" rowspan="1" valign="top">Test image</th>
                            <th align="left" colspan="1" rowspan="1" valign="top">Description</th>
                            <th align="left" colspan="1" rowspan="1" valign="top">Expected outcome</th>
                            <th align="left" colspan="1" rowspan="1" valign="top">Pass/fail</th>
                            <th align="left" colspan="1" rowspan="1" valign="top">Comment</th>
                        </tr>
                    </thead>
                    <tbody>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">Image 1</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Verify if atelectasis can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Atelectasis can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">PASS</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">Image 2</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Verify if cardiomegaly can be seen</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Cardiomegaly can be seen</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">PASS</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Cardiomegaly can be detected easily without difficulty</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">Image 3</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Verify if covid-19 can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Covid-19 can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">PASS</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">Image 4</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Verify if emphysema can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Emphysema can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">PASS</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">Image 5</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Verify if fibrosis can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Fibrosis can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">PASS</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">Image 6</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Verify if infiltration can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Infiltration can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">PASS</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Infiltration can be detected but further testing is needed to confirm it</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">Image 7</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Find any abnormalities in the image</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">No abnormalities should be seen</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">FAIL</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Some abnormalities were seen</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">Image 8</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Verify if pneumonia can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Pneumonia can be detected</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">PASS</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Pneumonia can be seen without any difficulty</td>
                        </tr>
                        <tr>
                            <td align="left" colspan="1" rowspan="1" valign="top">Image 9</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Verify if tuberculosis can be seen</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">Tuberculosis can be seen</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">PASS</td>
                            <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                        </tr>
                    </tbody>
                </table>
            </table-wrap>
            <p>Also, for Image 6, which was a 
                <italic toggle="yes">Medium</italic> resolution CLAHE-FFT, it was highlighted that further testing would be required to confirm the diagnosis of 
                <italic toggle="yes">Infiltration.</italic> Nonetheless it was generally concluded that no pathological differences were observed between all processed CXR and all digitalized CXR.</p>
        </sec>
        <sec id="sec10" sec-type="conclusions">
            <title>Conclusions</title>
            <p>In this paper, we presented the results of image processing techniques using CLAHE and its variations to enhance digitized X-ray films. Twenty-one physical X-ray films had been digitized via mobile phone capture at 
                <italic toggle="yes">Low</italic>, 
                <italic toggle="yes">Medium</italic>, and 
                <italic toggle="yes">High</italic> resolutions. Three different image enhancement methods with two different image compression techniques had been compared. Results of quantitative evaluation indicated that N-CLAHE may not be a suitable method due to producing an overexposure. Also, the performance of DCT or FFT did not affect the quality of output.</p>
            <p>Results of qualitative evaluation further validated the accuracy of the digitized X-ray with a medical practitioner. It had been found that the accuracy of correct diagnosis is close to the work by others in literatures. The overall presentation of the digitized X-ray had been found to be acceptable though some images might require further testing to confirm a diagnosis. Nevertheless, this paper had shown potential improvements with the proposed methods of enhancement that in turn may contribute to an increase efficiency in healthcare processes at rural clinics.</p>
        </sec>
        <sec id="sec11">
            <title>Author contributions</title>
            <p>
                <bold>Mohd-Isa W:</bold> Conceptualization, Formal Analysis, Project Administration, Supervision, Writing &#x2013; Original Draft Preparation, Writing &#x2013; Review &amp; Editing; 
                <bold>Joseph J:</bold> Data Curation, Investigation, Methodology, Investigation; 
                <bold>Hashim N:</bold> Conceptualization, Project Administration; 
                <bold>Salih N:</bold> Formal Analysis, Validation.</p>
        </sec>
        <sec id="sec12">
            <title>Data availability</title>
            <p>Figshare: CLAHE-Enhanced X-ray Images DOI: 
                <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.6084/m9.figshare.c.5490822">https://doi.org/10.6084/m9.figshare.c.5490822</ext-link>.
                <sup>
                    <xref ref-type="bibr" rid="ref25">25</xref>
                </sup>
            </p>
            <p>This project contains the following data:
                <list list-type="bullet">
                    <list-item>
                        <label>-</label>
                        <p>A collection of processed chest X-ray digitized images with CLAHE, MMCLAHE, N-CLAHE techniques and FFT and DCT compression.</p>
                    </list-item>
                </list>
            </p>
            <p>Data are available under the terms of the 
                <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/publicdomain/zero/1.0/">Creative Commons Zero &#x201c;No rights reserved&#x201d; data waiver</ext-link> (CC BY 4.0 Public domain dedication).</p>
            <p>Figshare. CLAHE-Enhanced X-ray Images</p>
            <p>This project contains the following data:
                <list list-type="bullet">
                    <list-item>
                        <label>-</label>
                        <p>Processed images after digitization of physical X-ray films using CLAHE, MMCLAHE, N-CLAHE, and DCT and FFT compression.</p>
                    </list-item>
                </list>
            </p>
            <p>Data are available under the terms of the 
                <ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/publicdomain/zero/1.0/">Creative Commons Zero &#x201c;No rights reserved&#x201d; data waiver</ext-link> (CC BY 4.0 Public domain dedication).</p>
        </sec>
    </body>
    <back>
        <ack>
            <title>Acknowledgements</title>
            <p>We thank the medical practitioner involved for assisting with evaluation of the results.</p>
        </ack>
        <ref-list>
            <title>References</title>
            <ref id="ref1">
                <label>1</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Khodaie</surname>
                            <given-names>M</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Askari</surname>
                            <given-names>A</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Bahaadinbeigy</surname>
                            <given-names>K</given-names>
                        </name>
</person-group>:
                    <article-title>Evaluation of a very low-cost and simple teleradiology technique.</article-title>
                    <source>

                        <italic toggle="yes">J. Digit. Imaging.</italic>
</source>
                    <year>2015</year>;<volume>28</volume>(<issue>3</issue>):<fpage>295</fpage>&#x2013;<lpage>301</lpage>.
                    <pub-id pub-id-type="pmid">25561065</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s10278-014-9756-2</pub-id>
                    <pub-id pub-id-type="pmcid">PMC4441694</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref2">
                <label>2</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Thati</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Sravanthi</surname>
                            <given-names>SB</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Narayana</surname>
                            <given-names>YV</given-names>
                        </name>
</person-group>:
                    <article-title>Optimized compression techniques for telemedicine therapeutic images.</article-title>
                    <source>

                        <italic toggle="yes">Proceedings of 2016 International Conference on Advanced Communication Control and Computing Technologies, ICACCCT 2016.</italic>
</source>
                    <year>2016</year>;<volume>978</volume>:<fpage>7</fpage>&#x2013;<lpage>11</lpage>.
                    <pub-id pub-id-type="doi">10.1109/ICACCCT.2016.7831760</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref3">
                <label>3</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Nasifoglu</surname>
                            <given-names>H</given-names>
                        </name>
</person-group>:
                    <article-title>Medical Image Compression for Telemedicine Applications.</article-title>
                    <source>

                        <italic toggle="yes">Archives in Biomedical Eng. &amp; Biotechn.</italic>
</source>
                    <year>2019</year>;<volume>2</volume>(<issue>1</issue>):<fpage>2</fpage>&#x2013;<lpage>4</lpage>.
                    <pub-id pub-id-type="doi">10.33552/abeb.2019.02.000527</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref4">
                <label>4</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Conway</surname>
                            <given-names>S</given-names>
                        </name>
</person-group>:
                    <article-title>Article - Teleradiology and telemedicine: They are not equal.</article-title>
                    <year>2016</year>.
                    <ext-link ext-link-type="uri" xlink:href="https://appliedradiology.com/articles/teleradiology-and-telemedicine-they-are-not-equal">Reference Source</ext-link>
                </mixed-citation>
            </ref>
            <ref id="ref5">
                <label>5</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Su-Lyn</surname>
                            <given-names>B</given-names>
                        </name>
</person-group>:
                    <article-title>Allow Telemedicine, Malaysia Urged, After Study Finds Higher Covid-19 Risk For Cancer Patients|CodeBlue.</article-title>
                    <year>2020</year>.
                    <ext-link ext-link-type="uri" xlink:href="https://codeblue.galencentre.org/2020/04/02/allow-telemedicine-malaysia-urged-after-study-finds-higher-covid-19-risk-for-cancer-patients/">Reference Source</ext-link>
                </mixed-citation>
            </ref>
            <ref id="ref6">
                <label>6</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Sackey</surname>
                            <given-names>AH</given-names>
                        </name>
</person-group>:
                    <article-title>A Low-Cost High-Quality Mobile X-ray Film Digitiser with Storage Facilities.</article-title>
                    <source>

                        <italic toggle="yes">SN Comprehensive Clin. Med.</italic>
</source>
                    <year>2019</year>;<volume>1</volume>(<issue>1</issue>):<fpage>1</fpage>&#x2013;<lpage>3</lpage>.
                    <pub-id pub-id-type="doi">10.1007/s42399-018-0011-x</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref7">
                <label>7</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Licurse</surname>
                            <given-names>MY</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Kim</surname>
                            <given-names>SH</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Kim</surname>
                            <given-names>W</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Comparison of diagnostic accuracy of plain film radiographs between original film and smartphone capture: a pilot study.</article-title>
                    <source>

                        <italic toggle="yes">J. Digit. Imaging.</italic>
</source>
                    <year>Dec 2015</year>;<volume>28</volume>(<issue>6</issue>):<fpage>646</fpage>&#x2013;<lpage>653</lpage>.
                    <pub-id pub-id-type="pmid">25840654</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s10278-015-9783-7</pub-id>
                    <pub-id pub-id-type="pmcid">PMC4636717</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref8">
                <label>8</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Westberg</surname>
                            <given-names>M</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Vasko</surname>
                            <given-names>T</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Owen</surname>
                            <given-names>LS</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Personal smartphones for neonatal diagnostic imaging: A prospective crossover study.</article-title>
                    <source>

                        <italic toggle="yes">J. Paediatr. Child Health.</italic>
</source>
                    <year>2017</year>;<volume>53</volume>(<issue>4</issue>):<fpage>343</fpage>&#x2013;<lpage>347</lpage>.
                    <pub-id pub-id-type="pmid">28194823</pub-id>
                    <pub-id pub-id-type="doi">10.1111/jpc.13467</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref9">
                <label>9</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Saenpaen</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Arwatchananukul</surname>
                            <given-names>S</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Aunsri</surname>
                            <given-names>N</given-names>
                        </name>
</person-group>:
                    <article-title>A comparison of image enhancement methods for lumbar spine X-ray image.</article-title>
                    <source>

                        <italic toggle="yes">ECTI-CON 2018-15
                            <sup>th</sup> International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology.</italic>
</source>
                    <year>2019</year>;<fpage>798</fpage>&#x2013;<lpage>801</lpage>.
                    <pub-id pub-id-type="doi">10.1109/ECTICon.2018.8620040</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref10">
                <label>10</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Staroverov</surname>
                            <given-names>NE</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Gryaznov</surname>
                            <given-names>AY</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Kholopova</surname>
                            <given-names>ED</given-names>
                        </name>
</person-group>:
                    <article-title>Digital X-ray image processing with using the adaptive histogram equalization and adaptive background correction.</article-title>
                    <source>

                        <italic toggle="yes">13th Russian-German Conference on Biomedical Engineering, XIII RGC, 23-25 May 2018, Aachen, Germany.</italic>
</source>
                    <pub-id pub-id-type="doi">10.18154/RWTH-CONV-224946</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref11">
                <label>11</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Kaur</surname>
                            <given-names>A</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Singh</surname>
                            <given-names>C</given-names>
                        </name>
</person-group>:
                    <article-title>Contrast enhancement for cephalometric images using wavelet-based modified adaptive histogram equalization.</article-title>
                    <source>

                        <italic toggle="yes">Appl. Soft Comput.</italic>
</source>
                    <year>2017</year>;<volume>51</volume>:<fpage>180</fpage>&#x2013;<lpage>191</lpage>.
                    <pub-id pub-id-type="doi">10.1016/j.asoc.2016.11.046</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref12">
                <label>12</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Magudeeswaran</surname>
                            <given-names>V</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Singh</surname>
                            <given-names>JF</given-names>
                        </name>
</person-group>:
                    <article-title>Contrast limited fuzzy adaptive histogram equalization for enhancement of brain images.</article-title>
                    <source>

                        <italic toggle="yes">Int. J. Imaging Syst. Technol.</italic>
</source>
                    <year>2017</year>;<volume>27</volume>(<issue>1</issue>):<fpage>98</fpage>&#x2013;<lpage>103</lpage>.
                    <pub-id pub-id-type="doi">10.1002/ima.22214</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref13">
                <label>13</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Qiu</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Harold Li</surname>
                            <given-names>H</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Zhang</surname>
                            <given-names>T</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Automatic x-ray image contrast enhancement based on parameter auto-optimization.</article-title>
                    <source>

                        <italic toggle="yes">J. Appl. Clin. Med. Phys.</italic>
</source>
                    <year>2017</year>;<volume>18</volume>(<issue>6</issue>):<fpage>218</fpage>&#x2013;<lpage>223</lpage>.
                    <pub-id pub-id-type="pmid">28875594</pub-id>
                    <pub-id pub-id-type="doi">10.1002/acm2.12172</pub-id>
                    <pub-id pub-id-type="pmcid">PMC5689921</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref14">
                <label>14</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Singh</surname>
                            <given-names>RP</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Dixit</surname>
                            <given-names>M</given-names>
                        </name>
</person-group>:
                    <article-title>Histogram equalization: a strong technique for image enhancement.</article-title>
                    <source>

                        <italic toggle="yes">Int. J. Sig. Process. Image Process. Pattern Recogn.</italic>
</source>
                    <year>2015</year>;<volume>8</volume>(<issue>8</issue>):<fpage>345</fpage>&#x2013;<lpage>352</lpage>.
                    <pub-id pub-id-type="doi">10.14257/ijsip.2015.8.8.35</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref15">
                <label>15</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Al Wadud</surname>
                            <given-names>MA</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Kabir</surname>
                            <given-names>MH</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Dewan</surname>
                            <given-names>MAA</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>A dynamic histogram equalization for image contrast enhancement.</article-title>
                    <source>

                        <italic toggle="yes">IEEE Trans. Consum. Electron.</italic>
</source>
                    <year>2017</year>;<volume>53</volume>(<issue>2</issue>):<fpage>593</fpage>&#x2013;<lpage>600</lpage>.
                    <pub-id pub-id-type="doi">10.1109/TCE.2007.381734</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref16">
                <label>16</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Wang</surname>
                            <given-names>X</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Peng</surname>
                            <given-names>Y</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Lu</surname>
                            <given-names>L</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>ChestX-Ray8: Hospital-Scale Chest X-Ray Database and Benchmarks on Weakly-Supervised Classification and Localization of Common Thorax Diseases.</article-title>
                    <source>

                        <italic toggle="yes">2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR).</italic>
</source>
                    <year>2017</year>;<fpage>3462</fpage>&#x2013;<lpage>3471</lpage>.
                    <pub-id pub-id-type="doi">10.1109/CVPR.2017.369</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref17">
                <label>17</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Scichilone</surname>
                            <given-names>F</given-names>
                        </name>
</person-group>:
                    <article-title>DSLR Camera App.</article-title>
                    <year>2014</year>.
                    <ext-link ext-link-type="uri" xlink:href="https://www.fulvioscichilone.it/dslr-camera-app/">Reference Source</ext-link>
                </mixed-citation>
            </ref>
            <ref id="ref18">
                <label>18</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Koonsanit</surname>
                            <given-names>K</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Thongvigitmanee</surname>
                            <given-names>S</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Pongnapang</surname>
                            <given-names>N</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Image enhancement on digital X-ray images using N-CLAHE.</article-title>
                    <source>

                        <italic toggle="yes">10th Biomedical Engineering International Conference 2017.</italic>
</source>
                    <year>January 2017</year>;<fpage>1</fpage>&#x2013;<lpage>4</lpage>.
                    <pub-id pub-id-type="doi">10.1109/BMEiCON.2017.8229130</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref19">
                <label>19</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Satone</surname>
                            <given-names>K</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Deshmukh</surname>
                            <given-names>A</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Ulhe</surname>
                            <given-names>P</given-names>
                        </name>
</person-group>:
                    <article-title>A review of image compression techniques.</article-title>
                    <source>

                        <italic toggle="yes">Proceedings of the International Conference on Electronics, Communication and Aerospace Technology, ICECA 2017.</italic>
</source>
                    <year>Jan 2017</year>;<fpage>97</fpage>&#x2013;<lpage>101</lpage>.
                    <pub-id pub-id-type="doi">10.1109/ICECA.2017.8203651</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref20">
                <label>20</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Ali</surname>
                            <given-names>AH</given-names>
                        </name>
</person-group>:
                    <article-title>Medical Image Data Compression using Hybrid Methods.</article-title>
                    <source>

                        <italic toggle="yes">ARPN J. Eng. App. Sci.</italic>
</source>
                    <year>2018</year>;<volume>13</volume>(<issue>5</issue>):<fpage>1877</fpage>&#x2013;<lpage>1886</lpage>.
                    <ext-link ext-link-type="uri" xlink:href="http://www.arpnjournals.org/jeas/research_papers/rp_2018/jeas_0318_6877.pdf">Reference Source</ext-link>
                </mixed-citation>
            </ref>
            <ref id="ref21">
                <label>21</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Aziz</surname>
                            <given-names>SA</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Sam</surname>
                            <given-names>SM</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Mohamed</surname>
                            <given-names>N</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>A review on region of interest-based hybrid medical image compression algorithms.</article-title>
                    <source>

                        <italic toggle="yes">Telkomnika Telecommunication Computing Electronics and Control.</italic>
</source>
                    <year>2020</year>;<volume>18</volume>(<issue>3</issue>):<fpage>1650</fpage>&#x2013;<lpage>1657</lpage>.
                    <pub-id pub-id-type="doi">10.12928/TELKOMNIKA.v18i3.14900</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref22">
                <label>22</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Kamargaonkar</surname>
                            <given-names>C</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Sharma</surname>
                            <given-names>M</given-names>
                        </name>
</person-group>:
                    <article-title>Hybrid medical image compression method using SPIHT algorithm and Haar wavelet transform.</article-title>
                    <source>

                        <italic toggle="yes">International Conference on Electrical, Electronics, and Optimization Techniques, ICEEOT 2016.</italic>
</source>
                    <year>2016</year>;<fpage>897</fpage>&#x2013;<lpage>900</lpage>.
                    <pub-id pub-id-type="doi">10.1109/ICEEOT.2016.7754817</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref23">
                <label>23</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Kaur</surname>
                            <given-names>M</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Wasson</surname>
                            <given-names>V</given-names>
                        </name>
</person-group>:
                    <article-title>ROI Based Medical Image Compression for Telemedicine Application.</article-title>
                    <source>

                        <italic toggle="yes">Procedia Computer Science.</italic>
</source>
                    <year>2015</year>;<volume>70</volume>:<fpage>579</fpage>&#x2013;<lpage>585</lpage>.
                    <pub-id pub-id-type="doi">10.1016/j.procs.2015.10.037</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref24">
                <label>24</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Hussain</surname>
                            <given-names>AJ</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Al-Fayadh</surname>
                            <given-names>A</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Radi</surname>
                            <given-names>N</given-names>
                        </name>
</person-group>:
                    <article-title>Image compression techniques: A survey in lossless and lossy algorithms.</article-title>
                    <source>

                        <italic toggle="yes">Neurocomputing.</italic>
</source>
                    <year>2018</year>;<volume>300</volume>:<fpage>44</fpage>&#x2013;<lpage>69</lpage>.
                    <pub-id pub-id-type="doi">10.1016/j.neucom.2018.02.094</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref25">
                <label>25</label>
                <mixed-citation publication-type="other">
                    <collab>Mohd-Isa</collab>:
                    <article-title>CLAHE-Enhanced X-ray Images. figshare.</article-title>
                    <source>

                        <italic toggle="yes">Collection.</italic>
</source>
                    <year>2021</year>.
                    <pub-id pub-id-type="doi">10.6084/m9.figshare.c.5490822.v1</pub-id>
                </mixed-citation>
            </ref>
        </ref-list>
    </back>
    <sub-article article-type="reviewer-report" id="report150520">
        <front-stub>
            <article-id pub-id-type="doi">10.5256/f1000research.76876.r150520</article-id>
            <title-group>
                <article-title>Reviewer response for version 1</article-title>
            </title-group>
            <contrib-group>
                <contrib contrib-type="author">
                    <name>
                        <surname>Singh</surname>
                        <given-names>Himanshu</given-names>
                    </name>
                    <xref ref-type="aff" rid="r150520a1">1</xref>
                    <role>Referee</role>
                    <uri content-type="orcid">https://orcid.org/0000-0002-0410-0602</uri>
                </contrib>
                <aff id="r150520a1">
                    <label>1</label>Discipline of Electronics and Communication Engineering, Indian Institute of Information Technology, Design and Manufacturing, Jabalpur, Madhya Pradesh, India</aff>
            </contrib-group>
            <author-notes>
                <fn fn-type="conflict">
                    <p>
                        <bold>Competing interests: </bold>No competing interests were disclosed.</p>
                </fn>
            </author-notes>
            <pub-date pub-type="epub">
                <day>20</day>
                <month>9</month>
                <year>2022</year>
            </pub-date>
            <permissions>
                <copyright-statement>Copyright: &#x00a9; 2022 Singh H</copyright-statement>
                <copyright-year>2022</copyright-year>
                <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
                    <license-p>This is an open access peer review report distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
                </license>
            </permissions>
            <related-article ext-link-type="doi" id="relatedArticleReport150520" related-article-type="peer-reviewed-article" xlink:href="10.12688/f1000research.73236.1"/>
            <custom-meta-group>
                <custom-meta>
                    <meta-name>recommendation</meta-name>
                    <meta-value>approve</meta-value>
                </custom-meta>
            </custom-meta-group>
        </front-stub>
        <body>
            <p>Results of qualitative evaluation further validated the accuracy of the digitized X-ray with a medical practitioner. It had been found that the accuracy of correct diagnosis is close to the work by others in the literature. The overall presentation of the digitized X-ray had been found to be acceptable though some images might require further testing to confirm a diagnosis. Nevertheless, this paper had shown potential improvements with the proposed methods of enhancement that in turn may contribute to an efficiency increase in healthcare processes at rural clinics.&#x00a0;</p>
            <p> This manuscript can be accepted.</p>
            <p>Is the work clearly and accurately presented and does it cite the current literature?</p>
            <p>Yes</p>
            <p>If applicable, is the statistical analysis and its interpretation appropriate?</p>
            <p>Partly</p>
            <p>Are all the source data underlying the results available to ensure full reproducibility?</p>
            <p>Partly</p>
            <p>Is the study design appropriate and is the work technically sound?</p>
            <p>Yes</p>
            <p>Are the conclusions drawn adequately supported by the results?</p>
            <p>Yes</p>
            <p>Are sufficient details of methods and analysis provided to allow replication by others?</p>
            <p>Yes</p>
            <p>Reviewer Expertise:</p>
            <p>signal and image processing, machine learning</p>
            <p>I confirm that I have read this submission and believe that I have an appropriate level of expertise to confirm that it is of an acceptable scientific standard.</p>
        </body>
    </sub-article>
    <sub-article article-type="reviewer-report" id="report97129">
        <front-stub>
            <article-id pub-id-type="doi">10.5256/f1000research.76876.r97129</article-id>
            <title-group>
                <article-title>Reviewer response for version 1</article-title>
            </title-group>
            <contrib-group>
                <contrib contrib-type="author">
                    <name>
                        <surname>Sudirman</surname>
                        <given-names>Rubita</given-names>
                    </name>
                    <xref ref-type="aff" rid="r97129a1">1</xref>
                    <role>Referee</role>
                </contrib>
                <aff id="r97129a1">
                    <label>1</label>Division of Electronic and Computer Engineering, School of Electrical Engineering, Faculty of Engineering, Universiti Teknologi Malaysia, Johor Bahru, Malaysia</aff>
            </contrib-group>
            <author-notes>
                <fn fn-type="conflict">
                    <p>
                        <bold>Competing interests: </bold>No competing interests were disclosed.</p>
                </fn>
            </author-notes>
            <pub-date pub-type="epub">
                <day>15</day>
                <month>11</month>
                <year>2021</year>
            </pub-date>
            <permissions>
                <copyright-statement>Copyright: &#x00a9; 2021 Sudirman R</copyright-statement>
                <copyright-year>2021</copyright-year>
                <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
                    <license-p>This is an open access peer review report distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
                </license>
            </permissions>
            <related-article ext-link-type="doi" id="relatedArticleReport97129" related-article-type="peer-reviewed-article" xlink:href="10.12688/f1000research.73236.1"/>
            <custom-meta-group>
                <custom-meta>
                    <meta-name>recommendation</meta-name>
                    <meta-value>approve-with-reservations</meta-value>
                </custom-meta>
            </custom-meta-group>
        </front-stub>
        <body>
            <p>1. The methods provides some overview on how the digital x-ray images are processed, however, this section is missing the important equations to the algorithm employed to perform the processing.</p>
            <p> </p>
            <p> 2. Statistical analysis and its interpretation are not cited,&#x00a0;to show the performance of CLACHE designed.</p>
            <p> </p>
            <p> 3. In the conclusion, some brief numerical results should also be included to strengthen the finding from the study.&#x00a0;</p>
            <p> </p>
            <p> 4. There is no comparison made to past research, whether in the results or discussion section or in the conclusion. Adding some comparisons would enhance the quality of the paper.</p>
            <p>Is the work clearly and accurately presented and does it cite the current literature?</p>
            <p>Yes</p>
            <p>If applicable, is the statistical analysis and its interpretation appropriate?</p>
            <p>Partly</p>
            <p>Are all the source data underlying the results available to ensure full reproducibility?</p>
            <p>Yes</p>
            <p>Is the study design appropriate and is the work technically sound?</p>
            <p>Yes</p>
            <p>Are the conclusions drawn adequately supported by the results?</p>
            <p>Partly</p>
            <p>Are sufficient details of methods and analysis provided to allow replication by others?</p>
            <p>Partly</p>
            <p>Reviewer Expertise:</p>
            <p>signal processing, image processing, rehabilitation</p>
            <p>I confirm that I have read this submission and believe that I have an appropriate level of expertise to confirm that it is of an acceptable scientific standard, however I have significant reservations, as outlined above.</p>
        </body>
    </sub-article>
</article>