<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2 20190208//EN" "http://jats.nlm.nih.gov/publishing/1.2/JATS-journalpublishing1.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="systematic-review" dtd-version="1.2" xml:lang="en">
    <front>
        <journal-meta>
            <journal-id journal-id-type="pmc">F1000Research</journal-id>
            <journal-title-group>
                <journal-title>F1000Research</journal-title>
            </journal-title-group>
            <issn pub-type="epub">2046-1402</issn>
            <publisher>
                <publisher-name>F1000 Research Limited</publisher-name>
                <publisher-loc>London, UK</publisher-loc>
            </publisher>
        </journal-meta>
        <article-meta>
            <article-id pub-id-type="doi">10.12688/f1000research.147345.1</article-id>
            <article-categories>
                <subj-group subj-group-type="heading">
                    <subject>Systematic Review</subject>
                </subj-group>
                <subj-group>
                    <subject>Articles</subject>
                </subj-group>
            </article-categories>
            <title-group>
                <article-title>Influence of deep learning image reconstruction algorithm for reducing radiation dose and image noise compared to iterative reconstruction and filtered back projection for head and chest computed tomography examinations: a systematic review</article-title>
                <fn-group content-type="pub-status">
                    <fn>
                        <p>[version 1; peer review: 4 approved]</p>
                    </fn>
                </fn-group>
            </title-group>
            <contrib-group>
                <contrib contrib-type="author" corresp="no">
                    <name>
                        <surname>Chandran M</surname>
                        <given-names>Obhuli</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Conceptualization</role>
                    <role content-type="http://credit.niso.org/">Data Curation</role>
                    <role content-type="http://credit.niso.org/">Formal Analysis</role>
                    <role content-type="http://credit.niso.org/">Investigation</role>
                    <role content-type="http://credit.niso.org/">Methodology</role>
                    <role content-type="http://credit.niso.org/">Resources</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Original Draft Preparation</role>
                    <uri content-type="orcid">https://orcid.org/0000-0001-5515-6377</uri>
                    <xref ref-type="aff" rid="a1">1</xref>
                </contrib>
                <contrib contrib-type="author" corresp="no">
                    <name>
                        <surname>Pendem</surname>
                        <given-names>Saikiran</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Conceptualization</role>
                    <role content-type="http://credit.niso.org/">Data Curation</role>
                    <role content-type="http://credit.niso.org/">Investigation</role>
                    <role content-type="http://credit.niso.org/">Resources</role>
                    <role content-type="http://credit.niso.org/">Supervision</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Original Draft Preparation</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Review &amp; Editing</role>
                    <uri content-type="orcid">https://orcid.org/0000-0001-7933-1192</uri>
                    <xref ref-type="aff" rid="a1">1</xref>
                </contrib>
                <contrib contrib-type="author" corresp="no">
                    <name>
                        <surname>P S</surname>
                        <given-names>Priya</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Conceptualization</role>
                    <role content-type="http://credit.niso.org/">Methodology</role>
                    <role content-type="http://credit.niso.org/">Supervision</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Review &amp; Editing</role>
                    <uri content-type="orcid">https://orcid.org/0000-0002-7201-5733</uri>
                    <xref ref-type="aff" rid="a2">2</xref>
                </contrib>
                <contrib contrib-type="author" corresp="no">
                    <name>
                        <surname>Chacko</surname>
                        <given-names>Cijo</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Conceptualization</role>
                    <role content-type="http://credit.niso.org/">Methodology</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Review &amp; Editing</role>
                    <xref ref-type="aff" rid="a3">3</xref>
                </contrib>
                <contrib contrib-type="author" corresp="no">
                    <name>
                        <surname>.</surname>
                        <given-names>Priyanka</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Conceptualization</role>
                    <role content-type="http://credit.niso.org/">Data Curation</role>
                    <role content-type="http://credit.niso.org/">Methodology</role>
                    <role content-type="http://credit.niso.org/">Supervision</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Original Draft Preparation</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Review &amp; Editing</role>
                    <uri content-type="orcid">https://orcid.org/0000-0002-9792-6242</uri>
                    <xref ref-type="aff" rid="a1">1</xref>
                </contrib>
                <contrib contrib-type="author" corresp="yes">
                    <name>
                        <surname>Kadavigere</surname>
                        <given-names>Rajagopal</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Conceptualization</role>
                    <role content-type="http://credit.niso.org/">Formal Analysis</role>
                    <role content-type="http://credit.niso.org/">Methodology</role>
                    <role content-type="http://credit.niso.org/">Supervision</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Review &amp; Editing</role>
                    <uri content-type="orcid">https://orcid.org/0000-0003-3486-8740</uri>
                    <xref ref-type="corresp" rid="c1">a</xref>
                    <xref ref-type="aff" rid="a2">2</xref>
                </contrib>
                <aff id="a1">
                    <label>1</label>Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India</aff>
                <aff id="a2">
                    <label>2</label>Department of Radio Diagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India</aff>
                <aff id="a3">
                    <label>3</label>Philips Research and Development, Philips Innovation Campus, Yelahanka, Karnataka, 560064, India</aff>
            </contrib-group>
            <author-notes>
                <corresp id="c1">
                    <label>a</label>
                    <email xlink:href="mailto:rajarad@gmail.com">rajarad@gmail.com</email>
                </corresp>
                <fn fn-type="conflict">
                    <p>No competing interests were disclosed.</p>
                </fn>
            </author-notes>
            <pub-date pub-type="epub">
                <day>15</day>
                <month>4</month>
                <year>2024</year>
            </pub-date>
            <pub-date pub-type="collection">
                <year>2024</year>
            </pub-date>
            <volume>13</volume>
            <elocation-id>274</elocation-id>
            <history>
                <date date-type="accepted">
                    <day>26</day>
                    <month>3</month>
                    <year>2024</year>
                </date>
            </history>
            <permissions>
                <copyright-statement>Copyright: &#x00a9; 2024 Chandran M O et al.</copyright-statement>
                <copyright-year>2024</copyright-year>
                <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
                    <license-p>This is an open access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
                </license>
            </permissions>
            <self-uri content-type="pdf" xlink:href="https://f1000research.com/articles/13-274/pdf"/>
            <abstract>
                <sec>
                    <title>Background</title>
                    <p>The most recent advances in Computed Tomography (CT) image reconstruction technology are Deep learning image reconstruction (DLIR) algorithms. Due to drawbacks in Iterative reconstruction (IR) techniques such as negative image texture and nonlinear spatial resolutions, DLIRs are gradually replacing them. However, the potential use of DLIR in Head and Chest CT has to be examined further. Hence, the purpose of the study is to review the influence of DLIR on Radiation dose (RD), Image noise (IN), and outcomes of the studies compared with IR and FBP in Head and Chest CT examinations.</p>
                </sec>
                <sec>
                    <title>Methods</title>
                    <p>We performed a detailed search in PubMed, Scopus, Web of Science, Cochrane Library, and Embase to find the articles reported using DLIR for Head and Chest CT examinations between 2017 to 2023. Data were retrieved from the short-listed studies using Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines.</p>
                </sec>
                <sec>
                    <title>Results</title>
                    <p>Out of 196 articles searched, 15 articles were included. A total of 1292 sample size was included. 14 articles were rated as high and 1 article as moderate quality. All studies compared DLIR to IR techniques. 5 studies compared DLIR with IR and FBP. The review showed that DLIR improved IQ, and reduced RD and IN for CT Head and Chest examinations.</p>
                </sec>
                <sec>
                    <title>Conclusions</title>
                    <p>DLIR algorithm have demonstrated a noted enhancement in IQ with reduced IN for CT Head and Chest examinations at lower dose compared with IR and FBP. DLIR showed potential for enhancing patient care by reducing radiation risks and increasing diagnostic accuracy.</p>
                </sec>
            </abstract>
            <kwd-group kwd-group-type="author">
                <kwd>Low dose</kwd>
                <kwd>Computed tomography</kwd>
                <kwd>Deep learning image reconstruction</kwd>
                <kwd>Iterative reconstruction technique</kwd>
                <kwd>Image quality</kwd>
            </kwd-group>
            <funding-group>
                <funding-statement>The author(s) declared that no grants were involved in supporting this work.</funding-statement>
            </funding-group>
        </article-meta>
    </front>
    <body>
        <sec id="sec5" sec-type="intro">
            <title>Introduction</title>
            <p>Computed tomography (CT) plays an important role in modern diagnostic radiology and assists in the identification of various complex disorders. Over the past ten years, CT scan utilization has increased significantly globally as new clinical reasons are continually identified. An estimated 375 million CT examinations are continually performed annually worldwide, with a 3-4% annual growth rate. The demands of physicians and other health care providers, as well as technology developments, have had a considerable impact on the world market for CTs. Compared to other traditional imaging modalities, CT scans offer significantly higher radiation doses (RD) despite having significant diagnostic benefits for specific patients. Adult CT scans dramatically raise cancer risk. A positive correlation between RD and cancer risks was found.
                <sup>
                    <xref ref-type="bibr" rid="ref1">1</xref>
                </sup>
                <sup>&#x2013;</sup>
                <sup>
                    <xref ref-type="bibr" rid="ref5">5</xref>
                </sup>
            </p>
            <p>A recent study reported seventeen-fold variations in high-dose CT examinations among different countries. There is a four-fold variation in effective dose [ED] for Chest and abdomen examinations with less variation for CT head in adults and suggested optimization of radiation doses.
                <sup>
                    <xref ref-type="bibr" rid="ref6">6</xref>
                </sup> The most recommended practice in the CT sector is to reduce CT radiation exposure as low as reasonably achievable while maintaining the Image Quality (IQ). Reducing the exposure factors of tube voltage (kVp) and tube current (mA) reduces RD but increases image noise.
                <sup>
                    <xref ref-type="bibr" rid="ref7">7</xref>
                </sup>
                <sup>,</sup>
                <sup>
                    <xref ref-type="bibr" rid="ref8">8</xref>
                </sup> Up until ten years ago, Filtered back projection (FBP) was the only technique used for image reconstruction in CT. Although this method produces high-quality images it has noise issues at low doses and is prone to artifacts. Although an iterative reconstruction (IR) method was proposed in 1970, computational power restrictions prevented its widespread use in clinical settings. The Hybrid Iterative reconstruction (HIR) method was introduced in 2009 which had low computation time and allowed it to be implemented in clinical practice. The HIR combines iteratively reconstructed images in the raw data domain with FBP images to reduce image noise (IN). The first complete model-based iterative reconstruction (MBIR) received FDA approval in 2011. Compared to the HIR technique, this reconstruction minimizes artifacts and noise. However, it requires a greater computational power demand, which results in lengthy reconstruction times. IR techniques, irrespective of type produce lower IN, artifacts, or both at lower doses than FBP.
                <sup>
                    <xref ref-type="bibr" rid="ref9">9</xref>
                </sup>
                <sup>&#x2013;</sup>
                <sup>
                    <xref ref-type="bibr" rid="ref15">15</xref>
                </sup> However, in general, IR at higher levels of reconstruction may result in an artificial, plastic-looking, and blotchy appearance that would eventually lower the IQ and compromise the clinician&#x2019;s ability to diagnose pathologies, limiting the potential for significant RD reduction.
                <sup>
                    <xref ref-type="bibr" rid="ref16">16</xref>
                </sup>
                <sup>&#x2013;</sup>
                <sup>
                    <xref ref-type="bibr" rid="ref18">18</xref>
                </sup>
            </p>
            <p>Deep learning image reconstruction algorithms (DLIR) are the most recent developments in CT image reconstruction technology. DLIRs are increasingly replacing IR techniques due to their disadvantages such as negative image texture and nonlinear spatial resolutions. DLIR is based on deep convolution neural networks (CNN) which learn from the input data sets. It gains the ability to distinguish actual signal and IN through training using pairs of low and high-quality images. In comparison to FBP and IR, the trained CNNs can distinguish between noise and signal much better, allowing for better dose reduction while preserving the image quality. DLIR produces an image texture similar to that of FBP even at low doses and high strengths. DLIR technique may be able to detect the low contrast lesions at low doses without damaging the image texture.
                <sup>
                    <xref ref-type="bibr" rid="ref19">19</xref>
                </sup>
                <sup>&#x2013;</sup>
                <sup>
                    <xref ref-type="bibr" rid="ref22">22</xref>
                </sup> More research is required to determine the potential applications of DLIR in clinical settings. Our literature search showed there is no systematic review performed in head and chest CT examinations using Deep learning reconstruction algorithm for reducing RD and improving IQ in CT. Hence, the purpose of the article is to review the influence of DLIR on RD, IN, and outcomes of the studies compared with IR and FBP in CT Head and Chest examinations.</p>
        </sec>
        <sec id="sec6" sec-type="methods">
            <title>Methods</title>
            <sec id="sec7">
                <title>Design</title>
                <p>This review was carried out as per the &#x201c;Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA)&#x201d; guidelines.
                    <sup>
                        <xref ref-type="bibr" rid="ref23">23</xref>
                    </sup>
                </p>
            </sec>
            <sec id="sec8">
                <title>Literature search strategy</title>
                <p>A comprehensive literature search was performed using databases such as &#x201c;PubMed, Scopus, Web of Science, Cochrane Library, and Embase&#x201d; to find the relevant original studies (
                    <xref ref-type="table" rid="T1">Table 1</xref>). The MeSH terms such as &#x201c;Deep Learning Image Reconstruction&#x201d; &#x201c;Radiation dose&#x201d; &#x201c;Image quality&#x201d;, &#x201c;Head and Chest Computed Tomography&#x201d; were used (
                    <xref ref-type="table" rid="T2">Table 2</xref>). The search was limited to the English language including both adult and paediatric populations of Head and Chest CT examinations.</p>
                <table-wrap id="T1" orientation="portrait" position="float">
                    <label>Table 1. </label>
                    <caption>
                        <title>Study retrieval method from database.</title>
                    </caption>
                    <table content-type="article-table" frame="hsides">
                        <thead>
                            <tr>
                                <th align="left" colspan="1" rowspan="1" valign="top">Database</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Number of studies retrieved</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Total</th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">PubMed</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">32</td>
                                <td align="left" colspan="1" rowspan="5" valign="top">196</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Scopus</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">52</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Web of Science</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">58</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Cochrane Library</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">8</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Embase</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">46</td>
                            </tr>
                        </tbody>
                    </table>
                </table-wrap>
                <table-wrap id="T2" orientation="portrait" position="float">
                    <label>Table 2. </label>
                    <caption>
                        <title>Participants intervention comparison and outcome methodology for determining study selection criteria.</title>
                    </caption>
                    <table content-type="article-table" frame="hsides">
                        <thead>
                            <tr>
                                <th align="left" colspan="1" rowspan="1" valign="top">Characteristics</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Criteria</th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Study year</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">2017-2023</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Study Type</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Cohort study</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Population</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Patients undergoing CT Head and Chest examinations
                                    <break/>Adult and Paediatric Population</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Intervention</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Image reconstruction algorithms</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Comparator</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR vs IR or FBP</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Outcomes</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Radiation dose and Image quality</td>
                            </tr>
                        </tbody>
                    </table>
                    <table-wrap-foot>
                        <p>CT: Computed Tomography; DLIR: Deep Learning Image Reconstruction; IR: Iterative Reconstruction; FBP: Filtered Back Projection.</p>
                    </table-wrap-foot>
                </table-wrap>
            </sec>
            <sec id="sec9">
                <title>Selection criteria</title>
                <p>Articles were screened considering the Participant&#x2019;s Intervention Comparison and Outcome (PICO) methodology. Case studies, case reports, conference abstracts, letters, editorial reviews, meta-analyses, or surveys were not included. The title and abstract of all the articles were independently and blindly screened by the two researchers. The articles that described a comparison of DLIR algorithms with the IR technique or FBP were included in the final review. The exclusion criteria were phantom studies, physics-based performance of DLIR, other language than English, articles with no comparison of DLIR with FBP, HIR/MBIR, and articles with no Hounsfield Unit (HU), Contrast to Noise Ratio (CNR), Signal to Noise Ratio (SNR).</p>
            </sec>
            <sec id="sec10">
                <title>Data extraction</title>
                <p>Data from each article was assessed independently by two researchers and any differences were solved by the third researcher.</p>
            </sec>
            <sec id="sec11">
                <title>Quality assessment</title>
                <p>To evaluate the quality of all the included articles, the custom-made Quality Assessment (QA) scale was used.
                    <sup>
                        <xref ref-type="bibr" rid="ref24">24</xref>
                    </sup> The list of all the questions for the quality assessment (underlying data). A score of 1 was given if the answer to the question was &#x201c;yes&#x201d; and each study was assigned a score ranging from 0 to 18. Based on the total scores obtained by each study, the studies were classified into three quality levels: Low- quality studies (score of 6 or lower), Moderate-quality studies (score between 7 and 11), High-quality studies (score of 12 or more).</p>
            </sec>
        </sec>
        <sec id="sec12" sec-type="results">
            <title>Results</title>
            <p>Finally, 15 articles were included (
                <xref ref-type="fig" rid="f1">Figure 1</xref>).</p>
            <fig fig-type="figure" id="f1" orientation="portrait" position="float">
                <label>Figure 1. </label>
                <caption>
                    <title>Flow chart for study selection.</title>
                </caption>
                <graphic id="gr1" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/161532/1b067524-7ad8-4072-b5c6-b249c9369e06_figure1.gif"/>
            </fig>
            <sec id="sec13">
                <title>Study selection</title>
                <p>The search in PubMed, Scopus, Web of Science, Cochrane Library and Embase resulted in 196 studies. 101 duplicates were removed. The title and abstract of 95 studies were assessed and 76 studies were excluded as they did not meet the inclusion criteria. A total of 19 reports were sought for retrieval. A total of the full text of 19 articles were assessed for eligibility. Among them, 4 articles were excluded (3 studies were excluded due to no comparison of DLIR with FBP and HIR/MBIR, and 1 article were excluded due to lack of HU, CNR, and SNR). Finally, 15 articles were included in the systematic review.</p>
            </sec>
            <sec id="sec14">
                <title>Characteristics of selected studies</title>
                <p>CT imaging has increased recently with the advancement in CT technology. The studies included in the review covered different countries such as China (n = 8), Japan (n = 1), France (n = 1), Korea (n = 3), Netherland (n =1), Sweden (n = 1). The RD data and IQ parameters were collected from different CT vendors such as General Electric (GE) Health care (128, 256, 512-slice, and dual-energy CT), Siemens Healthineers (256-slice), Canon Medical system (320 and 640-slice). A total sample size of 1292 was collected from the included studies. 4 studies used prospective data collection, and 11 studies used retrospective data collection. The characteristics of the study and the outcomes of each study are summarized in 
                    <xref ref-type="table" rid="T3">Table 3</xref>.</p>
                <table-wrap id="T3" orientation="portrait" position="float">
                    <label>Table 3. </label>
                    <caption>
                        <title>Characteristics of selected studies for Head and Chest CT examinations.</title>
                    </caption>
                    <table content-type="article-table" frame="hsides">
                        <thead>
                            <tr>
                                <th align="left" colspan="1" rowspan="1" valign="top">Author; Year and Country</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Method</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">CT exam</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Adult/Paediatric</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Reconstruction techniques</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Slice CT/Vendor</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Sample</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">QLA</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">QUA &amp; Region &amp; Lesion detection</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Outcome of the study</th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr>
                                <td align="left" colspan="10" rowspan="1" valign="top">
                                    <bold>CT Head (Adult)</bold>
                                </td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Alagic et al., 2022 Sweden
                                    <sup>
                                        <xref ref-type="bibr" rid="ref25">25</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non-contract CT Brain</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">AS-V (50%), DLIR-(L-H)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">512 Slice/GE</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">94</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">IN, brain structures, posterior fossa artifacts</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">CT, SD of GM, WM, ICH, SNR in the GM, WM and ICH
                                    <break/>Intracranial hemorrhage conspicuity</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">With substantially less non-diagnostic images, greater SNR (82.9%), and higher CNR (53.3%) compared to AS-V (50%), IQ of CT Brain with DLIR-M&amp;H revealed dramatically increased IQ.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Kim I. et al., 2021 Korea
                                    <sup>
                                        <xref ref-type="bibr" rid="ref26">26</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non contrast Brain</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">AS-V (30%), DLIR (L-H)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">512- slice/GE</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">62</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Artefacts, IQ, IN</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">CT HU of GM, Image Noise, Artifact index, CNR &#x2013; Basal ganglia and Centrum semiovale.
                                    <break/>SNR &amp; SD, Reconstruction time</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR(M&amp;H) exhibited reduction in IN and artifacts in Posterior fossa compared with AS-V.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Nagayama et al., 2023 Japan
                                    <sup>
                                        <xref ref-type="bibr" rid="ref27">27</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non-Contrast CT Brain</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-HIR, MBIR, DLIR</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">320-Slice/CMS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">114</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Noise magnitude, IT, GM-WM differentiation, Artifact, IS, OIQ,</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">GM-WM differentiation, CNR, HU, SD
                                    <break/>GM, WM
                                    <break/>Lesion Conspicuity</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR can enhance the IQ of the CT Brain while reducing low RD and reconstruction time.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Oostveen et al., 2021 Netherland
                                    <sup>
                                        <xref ref-type="bibr" rid="ref28">28</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non-Contrast CT Brain</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR, MBIR, HIR</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">320-slice/CMS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">50</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">IN, IS, natural appearance, GWM diff., artefacts, OIQ</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SNR &amp; SD of CSF, Reconstruction time</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Comparing DILR to MBIR and HIR leads in reduced IN and better tissue differentiation with a little increase in reconstruction time.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="10" rowspan="1" valign="top">
                                    <bold>CT Head (Pediatric)</bold>
                                </td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Sun J et al., 2021China
                                    <sup>
                                        <xref ref-type="bibr" rid="ref29">29</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non contrast CT Brain</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Pediatric</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">FBP, AS-V 50% and 100% DLIR (High)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">256-slice/GE</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">50</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Clarity of cistern boundaries, GWM differentiation, Image quality</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">GM HU and SD, WM HU and SD, GM SNR, WM SNR,CNR</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">In comparison to AS-V and FBP, DLIR-H demonstrated reduced IN and increased IQ. Lesion identification is improved in 0.625 mm DLIR-H images, which also have similar image noise levels to 5 mm AS-V (50%) images.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="10" rowspan="1" valign="top">
                                    <bold>CT Chest (Adult)</bold>
                                </td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Ferri et al., 2022 France
                                    <sup>
                                        <xref ref-type="bibr" rid="ref30">30</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non-contrast chest CT</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">FBP, AS-V 70% and DLIR (L-H)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">256-Slice/GE</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">54</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">OIQ,IN, artefacts</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">HU, SD, SNR (Air, trachea, muscle). Emphysema volume</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SNR was significantly raised with DLIR. Emphysema volume decrease with increase strengths of DLIR.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Jiang B et al., 2022 China
                                    <sup>
                                        <xref ref-type="bibr" rid="ref31">31</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">PS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non contrast and contrast Chest</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">AS-V (40%, 80% and DLIR- M, H.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">256-slice/GE</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">203</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Lung tissue noise, air background noise
                                    <break/>Nodule detection rate
                                    <break/>Malignant-related features</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Measurement accuracy of nodule detection.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR showed better enhancement of nodule detection rate and reduced image noise compared with AS-V images.
                                    <break/>For DLIR-H, 81.5% malignancy-related characteristics detections were noted.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Jiang J. M. et al., 2022 China
                                    <sup>
                                        <xref ref-type="bibr" rid="ref32">32</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non contrast Chest CT</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">AS-V (50%) and DLIR (L-H)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">256-slice/GE</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">50</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Soft tissue and lung tissue</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SD, HU of (Aorta, Lung, Muscle, Liver, Vertebrae), CNR, SNR.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">At the same dosage, DLIR can deliver a greater IQ, boosting the doctors DC and raising the diagnostic accuracy of LDCT.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Jo et al., 2023 korea
                                    <sup>
                                        <xref ref-type="bibr" rid="ref33">33</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non contrast Chest CT</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">ADMIRE and DLIR (L-H)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Dual Source/Somatom Force</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">100</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SN, Spatial resolution, Distortion artifact, Beam hardening artifact, OIQ</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Noise, SNR, Edge rise distance
                                    <break/>Nodule detectability assessment</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">When compared to normal LDCT images reconstructed using IR, Quarter LD images reconstructed with DLIR demonstrated noninferior nodule detectability and IQ.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Kim J. H. et al., 2021 Korea
                                    <sup>
                                        <xref ref-type="bibr" rid="ref34">34</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non-Contrast Chest CT</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">AS-V 30% and (DLIR M &amp; H)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">512 Slice/GE</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">58</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">IC, IN &amp; conspicuity of structures</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">HU, SD, SNR and CNR (Lung, Mediastinum, Liver Air)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Compared with AS-V 30% the DLIR images exhibited IN reduction in LDCT images by maintaining IQ.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Kim C. H. et al., 2022 China
                                    <sup>
                                        <xref ref-type="bibr" rid="ref35">35</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non contrast chest CT</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">FBP, ASiR-V 30%, DLIR</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">512 Slice/GE</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">193</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Image contrast, OIQ</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">HU, SD, SNR and BRISQUE Score of lower lobes
                                    <break/>Diagnostic characterization of usual interstitial pneumonia (UIP)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR images produced highest OIQ score. Comparing DLIR to AS-V and FBP, IN, SNR, and visual rating of chest LD-CT scan images all improved. For purpose of diagnosing UIP DLIR may be useful.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Tian et al., 2022 China
                                    <sup>
                                        <xref ref-type="bibr" rid="ref36">36</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">RS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non contrast Chest CT</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">AS-V 40%, DLIR (L-H)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">256-slice/GE</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">86</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">IN, Image artifacts, and lesions.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">HU, SD, (Lung Muscle, Fat, Aorta)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Compared with AS-V 40%, DLIR effectively reduced IN and improved IQ in LD chest CT.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Wang et al., H 2022 China
                                    <sup>
                                        <xref ref-type="bibr" rid="ref37">37</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">PS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non contrast chest CT</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">AS- V 40%, DLIR M and H</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">256-slice/GE</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">48</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Nodules, Lung tissue, Artifacts and diagnostic confidence</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Objective Noise, CNR, Image Signal (Aorta)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">With DLIR, LD chest CT scans minimise IN, while DLIR-H provides images with a similar level of quality to SDCT AS (40%) while using just 4% of the RD.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Wang J et al., 2023 China
                                    <sup>
                                        <xref ref-type="bibr" rid="ref38">38</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">PS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Non contrast Chest CT</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">HIR, DLIR</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">640-slice/CMS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">60</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">OIQ</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SD, HU, and SNR (Aorta, Paraspinal muscle,fat)
                                    <break/>Assessment of Pulmonary lesion Conspicuity</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">In comparison to HIR, LDCT-DLIR offers an excellent IQ with the exception of sub-solid nodules and reduced lung attenuation.</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Zhao et al., 2022 China
                                    <sup>
                                        <xref ref-type="bibr" rid="ref39">39</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">PS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">HRCT and Low dose Chest</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Adult</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">HIR (AIDR3D, LDCT with DLIR</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">320-slice/CMS</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">70</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">OIQ, SIN, artifacts</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SNR
                                    <break/>Lung in ILD</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Low dose CT DLIR showed better recognition of ground glass opacity and visualization of architectural distortion than HRCT-AIDR</td>
                            </tr>
                        </tbody>
                    </table>
                    <table-wrap-foot>
                        <p>AIDR: Adaptive iterative dose reduction method 3D; AS-V: Adaptive statistical iterative reconstruction-V; CMS: Cannon medical systems; CT: Computed Tomography; CNR: Contrast to Noise ratio; DC: Diagnostic confidence; DLIR: Deep learning image reconstruction; GM: Gray matter; HU: Hounsfield Unit; HIR: Hybrid iterative reconstruction; H: High; HRCT: High resolution computed tomography;IN: Image noise; IQ: Image quality; IC: Image contrast; IT: Image texture; IS: Image sharpness; ICH: Intracranial hemorrhage; ILD: Interstitial lung disease; LD: Low dose; M: Medium; L: Low; NT: Noise texture; MBIR: Model based iterative reconstruction; OIQ: Objective image quality; PS: Prospective study; QLA: Qualitative analysis; QUA: Quantitative analysis; RD: Radiation dose; RS: Retrospective study; SD: Standard dose; sd: Standard deviation; SR: Spatial resolution; SNR: Signal to Noise ratio; SIN: Subjective image noise; UHRCT: Ultrahigh resolution CT; WM: White matter.</p>
                    </table-wrap-foot>
                </table-wrap>
            </sec>
            <sec id="sec15">
                <title>Quality assessment</title>
                <p>The results of the quality assessment are summarized in 
                    <xref ref-type="table" rid="T4">Table 4</xref>. All studies compared DLR to hybrid iterative reconstruction techniques. 5 studies compared DLIR with IR and FBP algorithms. A total of 14 studies were rated as high and 1 study as moderate quality.</p>
                <table-wrap id="T4" orientation="portrait" position="float">
                    <label>Table 4. </label>
                    <caption>
                        <title>Quality scores of the selected studies.</title>
                    </caption>
                    <table content-type="article-table" frame="hsides">
                        <thead>
                            <tr>
                                <th align="left" colspan="1" rowspan="1" valign="top"/>
                                <th align="left" colspan="1" rowspan="1" valign="top">CT Head</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Alagic et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref25">25</xref>
                                    </sup> 2022</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Kim I et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref26">26</xref>
                                    </sup> 2021</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Nagayama et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref27">27</xref>
                                    </sup> 2023</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Oostveen et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref28">28</xref>
                                    </sup>2021</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Sun J et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref29">29</xref>
                                    </sup> 2021</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">CT Thorax</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Ferri et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref30">30</xref>
                                    </sup> 2022</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Jiang B et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref31">31</xref>
                                    </sup> 2022</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Jiang J M et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref23">23</xref>
                                    </sup> 2022</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Jo et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref33">33</xref>
                                    </sup> 2023</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Kim J. H et al. 2021</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Kim C. H et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref34">34</xref>
                                    </sup> 2023</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Tian et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref36">36</xref>
                                    </sup> 2022</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Wang H et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref37">37</xref>
                                    </sup> 2022</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Wang J et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref38">38</xref>
                                    </sup> 2023</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Zhao et al.
                                    <sup>
                                        <xref ref-type="bibr" rid="ref39">39</xref>
                                    </sup> 2022</th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">1.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">2.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">3i.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">3ii.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">3iii.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">3iv.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">3v.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">3vi.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">4i.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">4ii.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">4iii.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">5.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">6i.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">6ii.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">7i.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">7ii.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">8i.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">8ii.</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">Total</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">14</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">14</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">14</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">13</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">13</td>
                                <td colspan="1" rowspan="1"/>
                                <td align="left" colspan="1" rowspan="1" valign="top">12</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">16</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">12</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">14</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">11</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">14</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">13</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">13</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">13</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">13</td>
                            </tr>
                        </tbody>
                    </table>
                </table-wrap>
            </sec>
            <sec id="sec16">
                <title>Image noise (IN) and radiation dose (RD) reduction in CT head and chest examinations</title>
                <p>
                    <italic toggle="yes">
                        <bold>CT head examination</bold>:</italic> We summarized the percentage IN and RD reduction for various CT examinations in 
                    <xref ref-type="table" rid="T5">Table 5</xref>. A total of five studies in CT brain that used DLIR showed a reduction in IN (18-52%) compared with IR and FBP.
                    <sup>
                        <xref ref-type="bibr" rid="ref25">25</xref>
                    </sup>
                    <sup>&#x2013;</sup>
                    <sup>
                        <xref ref-type="bibr" rid="ref29">29</xref>
                    </sup> In the brain, a study compared SD with IR (CTDIvol-70.8 mGy &amp; EF-2.8&#x00b1;0.2 mSv) and LD with DLIR (CTDIvol-53.0 mGy &amp; ED-2.1&#x00b1;0.1 mSv) protocol in adult CT brain and noticed a 25% reduction in RD.
                    <sup>
                        <xref ref-type="bibr" rid="ref27">27</xref>
                    </sup> Another study was done with LD DLIR (CTDIvol-18.18 mGy, DLP- 269.43 mGy.cm) protocol of CT brain.
                    <sup>
                        <xref ref-type="bibr" rid="ref29">29</xref>
                    </sup>
                </p>
                <table-wrap id="T5" orientation="portrait" position="float">
                    <label>Table 5. </label>
                    <caption>
                        <title>Radiation dose parameters and percentage reduction in radiation dose, image noise of CT Head and Chest.</title>
                    </caption>
                    <table content-type="article-table" frame="hsides">
                        <thead>
                            <tr>
                                <th align="left" colspan="1" rowspan="1" valign="top">S.No</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Author</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">CTDI vol (mGy)</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">DLP (mGy.cm)</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">SSDE (mGy)</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">ED (mSv)</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">% reduction in radiation dose</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">% reduction in Image noise</th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr>
                                <td align="left" colspan="8" rowspan="1" valign="top">
                                    <bold>CT Head (Adult)</bold>
                                </td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">1.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Alagic et al 2022
                                    <sup>
                                        <xref ref-type="bibr" rid="ref25">25</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Mean
                                    <break/>46.96&#x00b1;0.49</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Mean
                                    <break/>847.84&#x00b1;22.25</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR H reduced IN by 37.2% (AS- V 50)</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">2.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Kim et al 2021
                                    <sup>
                                        <xref ref-type="bibr" rid="ref26">26</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">35.90&#x00b1;3.36</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">768.38&#x00b1;86.61</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR H reduced 52.25 compared to AS V 30%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">3.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Nagayama et al 2023
                                    <sup>
                                        <xref ref-type="bibr" rid="ref27">27</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SD-70.8
                                    <break/>LD-53.0</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SD-2.8&#x00b1;0.2
                                    <break/>LD-2.1&#x00b1;0.1</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">25%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD DLIR reduced IN to 22.2% compared to LD HIR</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">4.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Oostveen et al 2021
                                    <sup>
                                        <xref ref-type="bibr" rid="ref28">28</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">16.1-52.7</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR showed reduce IN to 23.31 compared to MBIR and 11% compared to HIR</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="8" rowspan="1" valign="top">
                                    <bold>CT Head (Pediatric)</bold>
                                </td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">5.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Sun J et al 2021
                                    <sup>
                                        <xref ref-type="bibr" rid="ref29">29</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-18.18&#x00b1;2.82</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-269.43&#x00b1;57.95</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR-H showed reduced IN to 5.5% compared to AS-V 100% and 18% compared to AS-V 50%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="8" rowspan="1" valign="top">
                                    <bold>CT Chest (Adult)</bold>
                                </td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">6.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Ferri et al 2022
                                    <sup>
                                        <xref ref-type="bibr" rid="ref30">30</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-2.38&#x00b1;0.68</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-98.7&#x00b1;26.5</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR H reduced IN by 35.1% compared with AS-V</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">7.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Jiang B et al 2022
                                    <sup>
                                        <xref ref-type="bibr" rid="ref31">31</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">CECT-4.9&#x00b1;0.7
                                    <break/>ULD1-0.13
                                    <break/>ULD2-0.27</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">CECT-169.9&#x00b1;26.4
                                    <break/>ULD1-5.1&#x00b1;0.3
                                    <break/>ULD2-10.2&#x00b1;0.6</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">CECT-2.38&#x00b1;0.37
                                    <break/>ULD1-0.07
                                    <break/>ULD2-0.14</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">94-97%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR H reduced image noise by 9% compared to AV 40%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">8.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Jiang J M et al 2022
                                    <sup>
                                        <xref ref-type="bibr" rid="ref32">32</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-2.04</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-79.69&#x00b1;4.81</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-1.07&#x00b1;0.07</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIRH reduced IN by 11%.5 compared with AS V</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">9.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Jo et al 2023
                                    <sup>
                                        <xref ref-type="bibr" rid="ref33">33</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">QLD-0.29
                                    <break/>LD-1.2</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">QLD-11.6
                                    <break/>LD-46.4</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">QLD-0.16
                                    <break/>LD-0.65</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">75%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">QLD-DLIR showed reduced IN by 28.1 compared with ADMIRE</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">10.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Kim et al 2021
                                    <sup>
                                        <xref ref-type="bibr" rid="ref34">34</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-1.07</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-53.9&#x00b1;2.3</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-0.69&#x00b1;0.05</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-0.75&#x00b1;0.03</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR H reduced IN to 18.33% compared with AS V 30%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">11.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Kim et al 2023
                                    <sup>
                                        <xref ref-type="bibr" rid="ref35">35</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-1.96&#x00b1;0.03</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-70.32&#x00b1;5.82</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-0.98&#x00b1;0.08</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR M reduced IN to 14% compared with AS V 30%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">12.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Tian et al (2022)
                                    <sup>
                                        <xref ref-type="bibr" rid="ref36">36</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LD-1.03&#x00b1;0.36</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR H reduced IN to 33.3% compared to AS-V 40%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">13.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Wang H et al 2022
                                    <sup>
                                        <xref ref-type="bibr" rid="ref37">37</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SD-12.46&#x00b1;1.16
                                    <break/>LD-0.54</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SD-447.32&#x00b1;34.51
                                    <break/>LD-19.44&#x00b1;1.37</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">95%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR-H reduced IN to 56.29% compared to AS V 40%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">14.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Wang J et al 2023
                                    <sup>
                                        <xref ref-type="bibr" rid="ref38">38</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SD-4.88&#x00b1;1.56 (3.10-9.90)
                                    <break/>LD-0.70</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SD-146.08&#x00b1;46.49 (77.17-311.94)
                                    <break/>LD-20.54&#x00b1;2.10
                                    <break/>(14.29-23.84)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">-</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">SD-2.05&#x00b1;0.65
                                    <break/>(1.08-4.37)
                                    <break/>LD-0.29&#x00b1;0.03
                                    <break/>(0.20-0.33)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">85%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">LDCT DLIR H reduced IN to 33.8% compared to LDCT HIR</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">15.</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">Zhao et al 2022
                                    <sup>
                                        <xref ref-type="bibr" rid="ref39">39</xref>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">HRCT-5.38&#x00b1;1.49
                                    <break/>LDCT-2.00</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">228.99&#x00b1;62.69 (HRCT)
                                    <break/>87.38&#x00b1;6.01 (LDCT)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">7.29&#x00b1;1.45 (HRCT)
                                    <break/>2.78&#x00b1;0.26 (LDCT)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1.93&#x00b1;0.55 (HRCT)
                                    <break/>0.72&#x00b1;0.07</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">61.9%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">DLIR H showed reduced IN to 30.76% compared to AIDR</td>
                            </tr>
                        </tbody>
                    </table>
                    <table-wrap-foot>
                        <p>AIDR: Adaptive iterative dose reduction method 3D; AS-V: Adaptive statistical iterative reconstruction-V; CECT: Contrast Enhanced CT; DLIR: Deep learning image reconstruction; DLP; Dose length product; ED: Effective dose; FIRST: Forward projected model-based iterative reconstruction solution; H- High, HIR: Hybrid iterative reconstruction; HRCT: High resolution computed tomography; IN:Image noise; kVp: kilo voltage; QLD: Quarter Low dose; LD: Low dose; M: Medium; ULD: Ultra low dose; SSDE: Size specific dose estimate; SD: Standard dose.</p>
                    </table-wrap-foot>
                </table-wrap>
                <p>
                    <bold>
                        <italic toggle="yes">CT chest examination:</italic>
                    </bold> A total of nine studies from chest CT that used DLIR showed a reduction in IN (9-50%) compared with IR and FBP.
                    <sup>
                        <xref ref-type="bibr" rid="ref30">30</xref>
                    </sup>
                    <sup>&#x2013;</sup>
                    <sup>
                        <xref ref-type="bibr" rid="ref39">39</xref>
                    </sup> Four studies compared LD with DLIR and SD with IR for chest CT and observed a reduction (62-97%) in RD.
                    <sup>
                        <xref ref-type="bibr" rid="ref31">31</xref>
                    </sup>
                    <sup>,</sup>
                    <sup>
                        <xref ref-type="bibr" rid="ref37">37</xref>
                    </sup>
                    <sup>&#x2013;</sup>
                    <sup>
                        <xref ref-type="bibr" rid="ref39">39</xref>
                    </sup> Another 4 studies done with LD chest CT with DLIR [CTDI vol (1.07-2.38 mGy.cm), DLP (79.69-08.7 mGy.cm), SSDE (0.69-1.07 mGy), ED (0.98-1.03 mSv)].
                    <sup>
                        <xref ref-type="bibr" rid="ref30">30</xref>
                    </sup>
                    <sup>,</sup>
                    <sup>
                        <xref ref-type="bibr" rid="ref32">32</xref>
                    </sup>
                    <sup>,</sup>
                    <sup>
                        <xref ref-type="bibr" rid="ref34">34</xref>
                    </sup>
                    <sup>,</sup>
                    <sup>
                        <xref ref-type="bibr" rid="ref35">35</xref>
                    </sup> One study done with Quarter low dose (QLD) CT Chest using DLIR showed 75% reduction in radiation dose compared to IR.
                    <sup>
                        <xref ref-type="bibr" rid="ref33">33</xref>
                    </sup>
                </p>
            </sec>
        </sec>
        <sec id="sec17" sec-type="discussion">
            <title>Discussion</title>
            <p>This systematic review focussed on investigating the influence of DLIR on RD, IN, and outcomes of the studies compared with IR and FBP in Head and Chest CT examinations.</p>
            <sec id="sec18">
                <title>CT head</title>
                <p>Our review noted that for CT Brain examination, DLIR (Medium and High) showed reduced IN (18-52%), improved IQ (GM-WM differentiation) with better detection of cerebral lesions, and reduced RD (25%). In the Pediatric CT brain, a study by Sun et al. noted that higher strength DLIR reduced image noise and noted better detection of cerebral lesions in 0.625 mm compared to 5 mm slice thickness. The thinner sections of DLIR-H were able to identify micro-hemorrhages of less than 3 mm.
                    <sup>
                        <xref ref-type="bibr" rid="ref29">29</xref>
                    </sup> Nagayama et al. demonstrated a 25% reduction in RD with LD CT-DLIR (120 kVp, 280 mA) compared to SD -IR (120 kVp, 350 mA) and also observed that DLIR had the highest sensitivity in lesion detection (2.9&#x00b1;0.2) compared to MBIR (1.9&#x00b1;0.5) and HIR (1.2&#x00b1;0.4) in adult CT brain.
                    <sup>
                        <xref ref-type="bibr" rid="ref27">27</xref>
                    </sup> Studies by Oostveen et al. and Nagayama et al. showed reduced reconstruction times 44 sec; 24&#x00b1;1 sec compared to MBIR (176 s &amp; 319&#x00b1;17 secs) for Non-contrast CT brain.
                    <sup>
                        <xref ref-type="bibr" rid="ref27">27</xref>
                    </sup>
                    <sup>&#x2013;</sup>
                    <sup>
                        <xref ref-type="bibr" rid="ref28">28</xref>
                    </sup> Studies by Alagic et al. and Sun et al. reported CTDIvol and DLP of 46.96&#x00b1;0.49 mGy; 847.84&#x00b1;2.25 mGy.cm and 18.18&#x00b1;2.82 mGy; 269.3&#x00b1;57.95 mGy.cm in adult and pediatric CT Head respectively.
                    <sup>
                        <xref ref-type="bibr" rid="ref25">25</xref>
                    </sup>
                    <sup>,</sup>
                    <sup>
                        <xref ref-type="bibr" rid="ref29">29</xref>
                    </sup>
                </p>
            </sec>
            <sec id="sec19">
                <title>CT chest</title>
                <p>Our review noted that LDCT of the chest with DLIR showed higher image contrast and lower IN (9-56%) and reduced RD (62-97%) compared with FBP and IR. Zhao et al. compared LDCT with DLIR (120kvp, 30 mAs) and HRCT with HIR (120kVp, Automatic tube current modulation) for the patients with interstitial lung disease (ILD) and noted that LDCT DLIR showed better visualization of honeycombing and assessment of bronchiectasis.
                    <sup>
                        <xref ref-type="bibr" rid="ref39">39</xref>
                    </sup> Kim et al. noted that DLIR-H yielded higher scores in determining the prominence of the lungs main structures of the lungs.
                    <sup>
                        <xref ref-type="bibr" rid="ref34">34</xref>
                    </sup> Jiang et al. noted that ULD-CT with DLIR under or overestimated the long diameter and sub-solid nodules compared with CECT Thorax. DLIR-H overestimated the solid and calcified nodules while underestimating the long diameter and amount of sub-nodules.
                    <sup>
                        <xref ref-type="bibr" rid="ref31">31</xref>
                    </sup> Wang et al. noted LDCT with DLIR provides higher scores for assessing pulmonary lesions except for sub-solid nodules or ground glass opacity nodules (GGN) compared to SD with HIR, whereas GGN greater than 4 mm can be picked up on LDCT DLIR images.
                    <sup>
                        <xref ref-type="bibr" rid="ref38">38</xref>
                    </sup> Tian et al. reported that DLIR-H appeared to be slightly smoothed and DLIR M provides higher structures on visualization of smoother structures.
                    <sup>
                        <xref ref-type="bibr" rid="ref36">36</xref>
                    </sup> Ferri et al. reported DLIR reconstruction series provided the smallest volume of emphysema compared with Adaptive statistical iterative reconstruction-V (ASIR-V) and FBP and also observed the increase in strength of DLIR led to a decrease in the size of emphysema.
                    <sup>
                        <xref ref-type="bibr" rid="ref30">30</xref>
                    </sup>
                </p>
                <p>The study has a few limitations. Firstly, we did not include phantom studies. Secondly, we did not perform meta-analysis due to heterogeneity in terms of scanners and protocols used for head and chest examinations. The adoption of DLIR algorithms holds promise for improving IQ, reducing RD, and mitigating IN in Head and Chest CT examinations compared to traditional IR and FBP techniques. Healthcare providers may consider incorporating DLIR into their imaging protocols to enhance patient care by reducing radiation risks while maintaining diagnostic accuracy. Furthermore, future research efforts should focus on optimizing DLIR algorithms, investigating their long-term effects on patient outcomes, and evaluating cost-effectiveness compared to conventional reconstruction methods. Additional studies exploring the application of DLIR in other anatomical regions and patient populations could further expand its utility and impact on healthcare delivery.</p>
            </sec>
        </sec>
        <sec id="sec20" sec-type="conclusion">
            <title>Conclusion</title>
            <p>In conclusion, DLIR is a versatile and valuable technology that consistently improves IQ, enhances lesion detection, reduces radiation exposure, and mitigates image artifacts across a wide range of medical imaging applications compared with IR and FBP. A careful selection of strengths of DLIR, slice thickness and radiation dose levels are required for evaluation of tiny lesions, which can overcome with next generation DLIR algorithms. Overall, DLIR holds promise for improving patient care and diagnostic accuracy in various clinical settings.</p>
            <sec id="sec21">
                <title>Ethics and consent</title>
                <p>The study did not involve any human participants and only systematic review was conducted; hence the written informed consent and Institutional ethical committee approval (IEC) was not required.</p>
            </sec>
        </sec>
    </body>
    <back>
        <sec id="sec24" sec-type="data-availability">
            <title>Data availability</title>
            <sec id="sec25">
                <title>Underlying data</title>
                <p>No data is associated with this article.</p>
            </sec>
            <sec id="sec26">
                <title>Extended data</title>
                <p>Figshare: F1000 DLIR Systematic Review. 
                    <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.6084/m9.figshare.25404226.v3">https://doi.org/10.6084/m9.figshare.25404226.v3</ext-link>.
                    <sup>

                        <xref ref-type="bibr" rid="ref40">40</xref>
</sup>
                </p>
                <p>This project contains the following underlying data:
                    <list list-type="bullet">
                        <list-item>
                            <label>&#x2022;</label>
                            <p>Quality assessment scale</p>
                        </list-item>
                        <list-item>
                            <label>&#x2022;</label>
                            <p>PRISMA Chart</p>
                        </list-item>
                    </list>
                </p>
            </sec>
            <sec id="sec27">
                <title>Reporting guidelines</title>
                <p>Figshare: PRISMA_2020_checklist.pdf, 
                    <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.6084/m9.figshare.25404226.v3">https://doi.org/10.6084/m9.figshare.25404226.v3</ext-link>.
                    <sup>

                        <xref ref-type="bibr" rid="ref40">40</xref>
</sup>
                </p>
                <p>Data are available under the terms of the 
                    <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International license</ext-link> (CC-BY 4.0)</p>
            </sec>
        </sec>
        <ref-list>
            <title>References</title>
            <ref id="ref1">
                <label>1</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Smith-Bindman</surname>
                            <given-names>R</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Miglioretti</surname>
                            <given-names>DL</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Johnson</surname>
                            <given-names>E</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Use of Diagnostic Imaging Studies and Associated Radiation Exposure for Patients Enrolled in Large Integrated Health Care Systems, 1996-2010.</article-title>
                    <source>

                        <italic toggle="yes">JAMA.</italic>
</source>
                    <year>2012</year>;<volume>307</volume>(<issue>22</issue>):<fpage>2400</fpage>&#x2013;<lpage>2409</lpage>.
                    <pub-id pub-id-type="pmid">22692172</pub-id>
                    <pub-id pub-id-type="doi">10.1001/jama.2012.5960</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref2">
                <label>2</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Pola</surname>
                            <given-names>A</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Corbella</surname>
                            <given-names>D</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Righini</surname>
                            <given-names>A</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Computed tomography use in a large Italian region: trend analysis 2004-2014 of emergency and outpatient CT examinations in children and adults.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Radiol.</italic>
</source>
                    <year>2018</year>;<volume>28</volume>(<issue>6</issue>):<fpage>2308</fpage>&#x2013;<lpage>2318</lpage>.
                    <pub-id pub-id-type="pmid">29318431</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s00330-017-5225-x</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref3">
                <label>3</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Mettler</surname>
                            <given-names>FA</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Huda</surname>
                            <given-names>W</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Yoshizumi</surname>
                            <given-names>TT</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog1.</article-title>
                    <source>

                        <italic toggle="yes">Radiology.</italic>
</source>
                    <year>2008</year>;<volume>248</volume>(<issue>1</issue>):<fpage>254</fpage>&#x2013;<lpage>263</lpage>.
                    <pub-id pub-id-type="pmid">18566177</pub-id>
                    <pub-id pub-id-type="doi">10.1148/radiol.2481071451</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref4">
                <label>4</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Agostini</surname>
                            <given-names>A</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Borgheresi</surname>
                            <given-names>A</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Granata</surname>
                            <given-names>V</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Technological advances in body CT: a primer for beginners.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Rev. Med. Pharmacol. Sci.</italic>
</source>
                    <year>2022</year>;<volume>26</volume>(<issue>21</issue>):<fpage>7918</fpage>&#x2013;<lpage>7937</lpage>.
                    <pub-id pub-id-type="pmid">36394741</pub-id>
                    <pub-id pub-id-type="doi">10.26355/eurrev_202211_30144</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref5">
                <label>5</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Cao</surname>
                            <given-names>CF</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Ma</surname>
                            <given-names>KL</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Shan</surname>
                            <given-names>H</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>CT Scans and Cancer Risks: A Systematic Review and Dose-response Meta-analysis.</article-title>
                    <source>

                        <italic toggle="yes">BMC Cancer.</italic>
</source>
                    <year>2022</year>;<volume>22</volume>(<issue>1</issue>):<fpage>1238</fpage>.
                    <pub-id pub-id-type="pmid">36451138</pub-id>
                    <pub-id pub-id-type="doi">10.1186/s12885-022-10310-2</pub-id>
                    <pub-id pub-id-type="pmcid">PMC9710150</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref6">
                <label>6</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Smith-Bindman</surname>
                            <given-names>R</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Wang</surname>
                            <given-names>Y</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Chu</surname>
                            <given-names>P</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>International variation in radiation dose for computed tomography examinations: prospective cohort study.</article-title>
                    <source>

                        <italic toggle="yes">BMJ.</italic>
</source>
                    <year>2019</year>;<volume>364</volume>:<fpage>k4931</fpage>.
                    <pub-id pub-id-type="doi">10.1136/bmj.k4931</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref7">
                <label>7</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Baskan</surname>
                            <given-names>O</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Erol</surname>
                            <given-names>C</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Ozbek</surname>
                            <given-names>H</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Effect of radiation dose reduction on image quality in adult head CT with noise-suppressing reconstruction system with a 256 slice MDCT.</article-title>
                    <source>

                        <italic toggle="yes">J. Appl. Clin. Med. Phys.</italic>
</source>
                    <year>2015</year>;<volume>16</volume>(<issue>3</issue>):<fpage>285</fpage>&#x2013;<lpage>296</lpage>.
                    <pub-id pub-id-type="pmid">26103494</pub-id>
                    <pub-id pub-id-type="doi">10.1120/jacmp.v16i3.5360</pub-id>
                    <pub-id pub-id-type="pmcid">PMC5690139</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref8">
                <label>8</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Kubo</surname>
                            <given-names>T</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Ohno</surname>
                            <given-names>Y</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Kauczor</surname>
                            <given-names>HU</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Radiation dose reduction in chest CT-Review of available options.</article-title>
                    <source>

                        <italic toggle="yes">Eur. J. Radiol.</italic>
</source>
                    <year>2014</year>;<volume>83</volume>(<issue>10</issue>):<fpage>1953</fpage>&#x2013;<lpage>1961</lpage>.
                    <pub-id pub-id-type="pmid">25066756</pub-id>
                    <pub-id pub-id-type="doi">10.1016/j.ejrad.2014.06.033</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref9">
                <label>9</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Willemink</surname>
                            <given-names>MJ</given-names>
                        </name>

                        <name name-style="western">
                            <surname>No&#x00eb;l</surname>
                            <given-names>PB</given-names>
                        </name>
</person-group>:
                    <article-title>The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Radiol.</italic>
</source>
                    <year>2019</year>;<volume>29</volume>(<issue>5</issue>):<fpage>2185</fpage>&#x2013;<lpage>2195</lpage>.
                    <pub-id pub-id-type="pmid">30377791</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s00330-018-5810-7</pub-id>
                    <pub-id pub-id-type="pmcid">PMC6443602</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref10">
                <label>10</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Willemink</surname>
                            <given-names>MJ</given-names>
                        </name>

                        <name name-style="western">
                            <surname>De Jong</surname>
                            <given-names>PA</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Leiner</surname>
                            <given-names>T</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Iterative reconstruction techniques for computed tomography Part 1: Technical principles.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Radiol.</italic>
</source>
                    <year>2013</year>;<volume>23</volume>:<fpage>1623</fpage>&#x2013;<lpage>1631</lpage>.
                    <pub-id pub-id-type="pmid">23314600</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s00330-012-2765-y</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref11">
                <label>11</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Willemink</surname>
                            <given-names>MJ</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Leiner</surname>
                            <given-names>T</given-names>
                        </name>

                        <name name-style="western">
                            <surname>De Jong</surname>
                            <given-names>PA</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Radiol.</italic>
</source>
                    <year>2013</year>;<volume>23</volume>:<fpage>1632</fpage>&#x2013;<lpage>1642</lpage>.
                    <pub-id pub-id-type="pmid">23322411</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s00330-012-2764-z</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref12">
                <label>12</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Hara</surname>
                            <given-names>AK</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Paden</surname>
                            <given-names>RG</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Silva</surname>
                            <given-names>AC</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study.</article-title>
                    <source>

                        <italic toggle="yes">Am. J. Roentgenol.</italic>
</source>
                    <year>2009</year>;<volume>193</volume>(<issue>3</issue>):<fpage>764</fpage>&#x2013;<lpage>771</lpage>.
                    <pub-id pub-id-type="doi">10.2214/AJR.09.2397</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref13">
                <label>13</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Geyer</surname>
                            <given-names>LL</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Schoepf</surname>
                            <given-names>UJ</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Meinel</surname>
                            <given-names>FG</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>State of the Art: Iterative CT Reconstruction Techniques.</article-title>
                    <source>

                        <italic toggle="yes">Radiology.</italic>
</source>
                    <year>2015</year>;<volume>276</volume>(<issue>2</issue>):<fpage>339</fpage>&#x2013;<lpage>357</lpage>.
                    <pub-id pub-id-type="doi">10.1148/radiol.2015132766</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref14">
                <label>14</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Han</surname>
                            <given-names>WK</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Na</surname>
                            <given-names>JC</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Park</surname>
                            <given-names>SY</given-names>
                        </name>
</person-group>:
                    <article-title>Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Radiol.</italic>
</source>
                    <year>2020</year>;<volume>30</volume>(<issue>2</issue>):<fpage>798</fpage>&#x2013;<lpage>805</lpage>.
                    <pub-id pub-id-type="pmid">31471753</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s00330-019-06423-1</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref15">
                <label>15</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Moloney</surname>
                            <given-names>F</given-names>
                        </name>

                        <name name-style="western">
                            <surname>James</surname>
                            <given-names>K</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Twomey</surname>
                            <given-names>M</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study.</article-title>
                    <source>

                        <italic toggle="yes">Emerg. Radiol.</italic>
</source>
                    <year>2019</year>;<volume>26</volume>(<issue>2</issue>):<fpage>169</fpage>&#x2013;<lpage>177</lpage>.
                    <pub-id pub-id-type="pmid">30448900</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s10140-018-1658-z</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref16">
                <label>16</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Stiller</surname>
                            <given-names>W</given-names>
                        </name>
</person-group>:
                    <article-title>Basics of iterative reconstruction methods in computed tomography: A vendor-independent overview.</article-title>
                    <source>

                        <italic toggle="yes">Eur. J. Radiol.</italic>
</source>
                    <year>2018</year>;<volume>109</volume>:<fpage>147</fpage>&#x2013;<lpage>154</lpage>.
                    <pub-id pub-id-type="pmid">30527298</pub-id>
                    <pub-id pub-id-type="doi">10.1016/j.ejrad.2018.10.025</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref17">
                <label>17</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Saiprasad</surname>
                            <given-names>G</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Filliben</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Peskin</surname>
                            <given-names>A</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Evaluation of Low-Contrast Detectability of Iterative Reconstruction across Multiple Institutions, CT Scanner Manufacturers, and Radiation Exposure Levels.</article-title>
                    <source>

                        <italic toggle="yes">Radiology.</italic>
</source>
                    <year>2015</year>;<volume>277</volume>(<issue>1</issue>):<fpage>124</fpage>&#x2013;<lpage>133</lpage>.
                    <pub-id pub-id-type="pmid">25989480</pub-id>
                    <pub-id pub-id-type="doi">10.1148/radiol.2015141260</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref18">
                <label>18</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Solomon</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Mileto</surname>
                            <given-names>A</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Ramirez-Giraldo</surname>
                            <given-names>JC</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Diagnostic Performance of an Advanced Modeled Iterative Reconstruction Algorithm for Low-Contrast Detectability with a Third-Generation Dual-Source Multidetector CT Scanner: Potential for Radiation Dose Reduction in a Multireader Study.</article-title>
                    <source>

                        <italic toggle="yes">Radiology.</italic>
</source>
                    <year>2015</year>;<volume>275</volume>(<issue>3</issue>):<fpage>735</fpage>&#x2013;<lpage>745</lpage>.
                    <pub-id pub-id-type="pmid">25751228</pub-id>
                    <pub-id pub-id-type="doi">10.1148/radiol.15142005</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref19">
                <label>19</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Zhang</surname>
                            <given-names>Z</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Seeram</surname>
                            <given-names>E</given-names>
                        </name>
</person-group>:
                    <article-title>The use of artificial intelligence in computed tomography image reconstruction - A literature review.</article-title>
                    <source>

                        <italic toggle="yes">J. Med. Imaging Radiat. Sci.</italic>
</source>
                    <year>2020</year>;<volume>51</volume>(<issue>4</issue>):<fpage>671</fpage>&#x2013;<lpage>677</lpage>.
                    <pub-id pub-id-type="doi">10.1016/j.jmir.2020.09.001</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref20">
                <label>20</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Koetzier</surname>
                            <given-names>LR</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Mastrodicasa</surname>
                            <given-names>D</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Szczykutowicz</surname>
                            <given-names>TP</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects.</article-title>
                    <source>

                        <italic toggle="yes">Radiology.</italic>
</source>
                    <year>2023</year>;<volume>306</volume>(<issue>3</issue>):<fpage>e221257</fpage>.
                    <pub-id pub-id-type="pmid">36719287</pub-id>
                    <pub-id pub-id-type="doi">10.1148/radiol.221257</pub-id>
                    <pub-id pub-id-type="pmcid">PMC9968777</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref21">
                <label>21</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Timothy</surname>
                            <given-names>P</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Szczykutowicz</surname>
                            <given-names>GVT</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Dhanantwari</surname>
                            <given-names>A</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>A Review of Deep Learning CT Reconstruction: Concepts, Limitations, and Promise in Clinical Practice.</article-title>
                    <source>

                        <italic toggle="yes">Curr. Radiol. Rep.</italic>
</source>
                    <year>2022</year>;<volume>10</volume>:<fpage>101</fpage>&#x2013;<lpage>115</lpage>.</mixed-citation>
            </ref>
            <ref id="ref22">
                <label>22</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Jensen</surname>
                            <given-names>CT</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Liu</surname>
                            <given-names>X</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Tamm</surname>
                            <given-names>EP</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Image quality assessment of abdominal CT by use of new deep learning image reconstruction: Initial experience.</article-title>
                    <source>

                        <italic toggle="yes">Am. J. Roentgenol.</italic>
</source>
                    <year>2020</year>;<volume>215</volume>(<issue>1</issue>):<fpage>50</fpage>&#x2013;<lpage>57</lpage>.
                    <pub-id pub-id-type="pmid">32286872</pub-id>
                    <pub-id pub-id-type="doi">10.2214/AJR.19.22332</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref23">
                <label>23</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Page</surname>
                            <given-names>MJ</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Mckenzie</surname>
                            <given-names>JE</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Bossuyt</surname>
                            <given-names>PM</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>The PRISMA 2020 statement: an updated guideline for reporting systematic reviews.</article-title>
                    <source>

                        <italic toggle="yes">BMJ.</italic>
</source>
                    <year>2021</year>;<volume>372</volume>:<fpage>n71</fpage>.
                    <pub-id pub-id-type="doi">10.1136/bmj.n71</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref24">
                <label>24</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Abel van Stiphout</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Driessen</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Koetzier</surname>
                            <given-names>LR</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>The effect of deep learning reconstruction on abdominal CT densitometry and image quality: a systematic review and meta-analysis.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Radiol.</italic>
</source>
                    <year>2022</year>;<volume>32</volume>:<fpage>2921</fpage>&#x2013;<lpage>2929</lpage>.
                    <pub-id pub-id-type="pmid">34913104</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s00330-021-08438-z</pub-id>
                    <pub-id pub-id-type="pmcid">PMC9038933</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref25">
                <label>25</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Alagic</surname>
                            <given-names>Z</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Diaz Cardenas</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Halldorsson</surname>
                            <given-names>K</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Deep learning versus iterative image reconstruction algorithm for head CT in trauma.</article-title>
                    <source>

                        <italic toggle="yes">Emerg. Radiol.</italic>
</source>
                    <year>2022</year>;<volume>29</volume>:<fpage>339</fpage>&#x2013;<lpage>352</lpage>.
                    <pub-id pub-id-type="pmid">34984574</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s10140-021-02012-2</pub-id>
                    <pub-id pub-id-type="pmcid">PMC8917108</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref26">
                <label>26</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Kim</surname>
                            <given-names>I</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Kang</surname>
                            <given-names>H</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Yoon</surname>
                            <given-names>HJ</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Deep learning-based image reconstruction for brain CT: improved image quality compared with adaptive statistical iterative reconstruction-Veo (ASIR-V).</article-title>
                    <source>

                        <italic toggle="yes">Neuroradiology.</italic>
</source>
                    <year>2021</year>;<volume>63</volume>(<issue>6</issue>):<fpage>905</fpage>&#x2013;<lpage>912</lpage>.
                    <pub-id pub-id-type="pmid">33037503</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s00234-020-02574-x</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref27">
                <label>27</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Nagayama</surname>
                            <given-names>Y</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Iwashita</surname>
                            <given-names>K</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Maruyama</surname>
                            <given-names>N</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Deep learning-based reconstruction can improve the image quality of low radiation dose head CT.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Radiol.</italic>
</source>
                    <year>2023</year>;<volume>33</volume>:<fpage>3253</fpage>&#x2013;<lpage>3265</lpage>.
                    <pub-id pub-id-type="pmid">36973431</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s00330-023-09559-3</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref28">
                <label>28</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Oostveen</surname>
                            <given-names>LJ</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Meijer</surname>
                            <given-names>FJA</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Lange</surname>
                            <given-names>F</given-names>
                            <prefix>de</prefix>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Deep learning&#x2013;based reconstruction may improve non-contrast cerebral CT imaging compared to other current reconstruction algorithms.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Radiol.</italic>
</source>
                    <year>2021</year>;<volume>31</volume>(<issue>8</issue>):<fpage>5498</fpage>&#x2013;<lpage>5506</lpage>.
                    <pub-id pub-id-type="pmid">33693996</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s00330-020-07668-x</pub-id>
                    <pub-id pub-id-type="pmcid">PMC8270865</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref29">
                <label>29</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Sun</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Li</surname>
                            <given-names>H</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Wang</surname>
                            <given-names>B</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Application of a deep learning image reconstruction (DLIR) algorithm in head CT imaging for children to improve image quality and lesion detection.</article-title>
                    <source>

                        <italic toggle="yes">BMC Med. Imaging.</italic>
</source>
                    <year>2021</year>;<volume>21</volume>(<issue>1</issue>):<fpage>1</fpage>&#x2013;<lpage>9</lpage>.</mixed-citation>
            </ref>
            <ref id="ref30">
                <label>30</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Ferri</surname>
                            <given-names>F</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Bouzerar</surname>
                            <given-names>R</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Auquier</surname>
                            <given-names>M</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Pulmonary emphysema quantification at low dose chest CT using Deep Learning image reconstruction.</article-title>
                    <source>

                        <italic toggle="yes">Eur. J. Radiol.</italic>
</source>
                    <year>2022</year>;<volume>152</volume>:<fpage>110338</fpage>.
                    <pub-id pub-id-type="pmid">35533559</pub-id>
                    <pub-id pub-id-type="doi">10.1016/j.ejrad.2022.110338</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref31">
                <label>31</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Jiang</surname>
                            <given-names>B</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Li</surname>
                            <given-names>N</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Shi</surname>
                            <given-names>X</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Deep Learning Reconstruction Shows Better Lung Nodule Detection for Ultra&#x2013;Low-Dose Chest CT.</article-title>
                    <source>

                        <italic toggle="yes">Radiology.</italic>
</source>
                    <year>2022</year>;<volume>303</volume>(<issue>1</issue>):<fpage>202</fpage>&#x2013;<lpage>212</lpage>.
                    <pub-id pub-id-type="pmid">35040674</pub-id>
                    <pub-id pub-id-type="doi">10.1148/radiol.210551</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref32">
                <label>32</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Jiang</surname>
                            <given-names>JM</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Miao</surname>
                            <given-names>L</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Liang</surname>
                            <given-names>X</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>The Value of Deep Learning Image Reconstruction in Improving the Quality of Low-Dose Chest CT Images.</article-title>
                    <source>

                        <italic toggle="yes">Diagnostics (Basel).</italic>
</source>
                    <year>2022</year>;<volume>12</volume>(<issue>10</issue>):<fpage>2560</fpage>.
                    <pub-id pub-id-type="pmid">36292249</pub-id>
                    <pub-id pub-id-type="doi">10.3390/diagnostics12102560</pub-id>
                    <pub-id pub-id-type="pmcid">PMC9601258</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref33">
                <label>33</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Jo</surname>
                            <given-names>GD</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Ahn</surname>
                            <given-names>C</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Hong</surname>
                            <given-names>JH</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>75% radiation dose reduction using deep learning reconstruction on low-dose chest CT.</article-title>
                    <source>

                        <italic toggle="yes">BMC Med. Imaging.</italic>
</source>
                    <year>2023 Sep 11</year>;<volume>23</volume>(<issue>1</issue>):<fpage>121</fpage>.
                    <pub-id pub-id-type="pmid">37697262</pub-id>
                    <pub-id pub-id-type="doi">10.1186/s12880-023-01081-8</pub-id>
                    <pub-id pub-id-type="pmcid">PMC10494344</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref34">
                <label>34</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Kim</surname>
                            <given-names>JH</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Yoon</surname>
                            <given-names>HJ</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Lee</surname>
                            <given-names>E</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Validation of deep-learning image reconstruction for low-dose chest computed tomography scan: Emphasis on image quality and noise.</article-title>
                    <source>

                        <italic toggle="yes">Korean J. Radiol.</italic>
</source>
                    <year>2021</year>;<volume>22</volume>(<issue>1</issue>):<fpage>131</fpage>&#x2013;<lpage>138</lpage>.
                    <pub-id pub-id-type="pmid">32729277</pub-id>
                    <pub-id pub-id-type="doi">10.3348/kjr.2020.0116</pub-id>
                    <pub-id pub-id-type="pmcid">PMC7772377</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref35">
                <label>35</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Kim</surname>
                            <given-names>CH</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Chung</surname>
                            <given-names>MJ</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Cha</surname>
                            <given-names>YK</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>The impact of deep learning reconstruction in low dose computed tomography on the evaluation of interstitial lung disease.</article-title>
                    <source>

                        <italic toggle="yes">PLoS One.</italic>
</source>
                    <year>2023</year>;<volume>18</volume>:<fpage>e0291745</fpage>.
                    <pub-id pub-id-type="pmid">37756357</pub-id>
                    <pub-id pub-id-type="doi">10.1371/journal.pone.0291745</pub-id>
                    <pub-id pub-id-type="pmcid">PMC10529569</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref36">
                <label>36</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Tian</surname>
                            <given-names>Q</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Li</surname>
                            <given-names>X</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Li</surname>
                            <given-names>J</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Image quality improvement in low-dose chest CT with deep learning image reconstruction.</article-title>
                    <source>

                        <italic toggle="yes">J. Appl. Clin. Med. Phys.</italic>
</source>
                    <year>2022</year>;<volume>23</volume>(<issue>12</issue>):<fpage>e13796</fpage>.
                    <pub-id pub-id-type="pmid">36210060</pub-id>
                    <pub-id pub-id-type="doi">10.1002/acm2.13796</pub-id>
                    <pub-id pub-id-type="pmcid">PMC9797160</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref37">
                <label>37</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Wang</surname>
                            <given-names>H</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Li</surname>
                            <given-names>LL</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Shang</surname>
                            <given-names>J</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Application of deep learning image reconstruction in low-dose chest CT scan.</article-title>
                    <source>

                        <italic toggle="yes">Br. J. Radiol.</italic>
</source>
                    <year>2022</year>;<volume>95</volume>(<issue>1133</issue>).
                    <pub-id pub-id-type="pmid">35084210</pub-id>
                    <pub-id pub-id-type="doi">10.1259/bjr.20210380</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref38">
                <label>38</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Wang</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Sui</surname>
                            <given-names>X</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Zhao</surname>
                            <given-names>R</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Radiol.</italic>
</source>
                    <year>2023</year>;<volume>34</volume>:<fpage>1053</fpage>&#x2013;<lpage>1064</lpage>.
                    <pub-id pub-id-type="doi">10.1007/s00330-023-10087-3</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref39">
                <label>39</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Zhao</surname>
                            <given-names>R</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Sui</surname>
                            <given-names>X</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Qin</surname>
                            <given-names>R</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Can deep learning improve image quality of low-dose CT: a prospective study in interstitial lung disease.</article-title>
                    <source>

                        <italic toggle="yes">Eur. Radiol.</italic>
</source>
                    <year>2022</year>;<volume>32</volume>(<issue>12</issue>):<fpage>8140</fpage>&#x2013;<lpage>8151</lpage>.
                    <pub-id pub-id-type="pmid">35748899</pub-id>
                    <pub-id pub-id-type="doi">10.1007/s00330-022-08870-9</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref40">
                <label>40</label>
                <mixed-citation publication-type="data">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Kadavigere</surname>
                            <given-names>R</given-names>
                        </name>
</person-group>:
                    <data-title>F1000 DLIR systematic review.</data-title>[Dataset].
                    <source>

                        <italic toggle="yes">figshare.</italic>
</source>
                    <year>2024</year>.
                    <pub-id pub-id-type="doi">10.6084/m9.figshare.25404226.v3</pub-id>
                </mixed-citation>
            </ref>
        </ref-list>
    </back>
    <sub-article article-type="reviewer-report" id="report268959">
        <front-stub>
            <article-id pub-id-type="doi">10.5256/f1000research.161532.r268959</article-id>
            <title-group>
                <article-title>Reviewer response for version 1</article-title>
            </title-group>
            <contrib-group>
                <contrib contrib-type="author">
                    <name>
                        <surname>MANIKANDAN</surname>
                        <given-names>SENTHIL</given-names>
                    </name>
                    <xref ref-type="aff" rid="r268959a1">1</xref>
                    <role>Referee</role>
                </contrib>
                <aff id="r268959a1">
                    <label>1</label>Assistant professor, Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bangalore, India</aff>
            </contrib-group>
            <author-notes>
                <fn fn-type="conflict">
                    <p>
                        <bold>Competing interests: </bold>No competing interests were disclosed.</p>
                </fn>
            </author-notes>
            <pub-date pub-type="epub">
                <day>29</day>
                <month>5</month>
                <year>2024</year>
            </pub-date>
            <permissions>
                <copyright-statement>Copyright: &#x00a9; 2024 MANIKANDAN S</copyright-statement>
                <copyright-year>2024</copyright-year>
                <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
                    <license-p>This is an open access peer review report distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
                </license>
            </permissions>
            <related-article ext-link-type="doi" id="relatedArticleReport268959" related-article-type="peer-reviewed-article" xlink:href="10.12688/f1000research.147345.1"/>
            <custom-meta-group>
                <custom-meta>
                    <meta-name>recommendation</meta-name>
                    <meta-value>approve</meta-value>
                </custom-meta>
            </custom-meta-group>
        </front-stub>
        <body>
            <p>
                <bold>Major comments:</bold>
            </p>
            <p> </p>
            <p> The objective of this study is to evaluate the impact of the Deep learning image reconstruction (DLIR's) algorithm on Radiation Dose (RD), Image Noise (IN), and Image Quality (IQ) in Head and Chest CT examinations. This study addresses a crucial area of research in image reconstruction technology in CT. The comprehensive approach ensures a thorough understanding of DLIR&#x2019;s impact on various aspects of CT Head and Chest imaging.</p>
            <p> The study's methodology is well-structured and follows the PRISMA guidelines, ensuring a systematic and comprehensive approach to data collection and analysis. The inclusion of major databases ensures a comprehensive retrieval of relevant articles, enhancing the study&#x2019;s credibility and readability.</p>
            <p> Findings regarding CT head examinations, including the reduction in image noise, improved Image quality with better lesion detection, and reduced radiation dose with DLIR compared to IR and FBP, are well documented and supported by specific studies. Similarly, the observations related to CT chest examinations, such as higher image contrast, lower image noise, and substantial reduction in radiation dose with DLIR, are clearly stated and backed by relevant research. Results mentioned in the study such as a reduction in RD 25% in adult CT brain examinations and 62% to 97% in chest CT examinations add quantitative support to the significant impact of DLIR reducing radiation exposure while maintaining diagnostic accuracy.</p>
            <p> Acknowledging the limitations of the study, such as the exclusion of phantom studies and heterogeneity provides transparency and enhances the credibility of acknowledging potential biases or gaps in the research process.</p>
            <p> </p>
            <p> 
                <bold>Minor comments: </bold>
            </p>
            <p> Ensure that all abbreviations are clearly defined upon first use.</p>
            <p> 
                <bold>Suggestions to editor</bold>
            </p>
            <p> The review article adds significant knowledge to the literature about the potential advantages of DLIR techniques to enhance diagnostic accuracy, minimize radiation exposure, and improve image quality in CT brain and Chest examinations. The review provides valuable insights into the advancements of DLIR in CT imaging, its benefits in reducing radiation dose and image noise while improving Image quality, and highlights the potential for further research and application of DLIR in clinical settings.</p>
            <p>Are the rationale for, and objectives of, the Systematic Review clearly stated?</p>
            <p>Yes</p>
            <p>Is the statistical analysis and its interpretation appropriate?</p>
            <p>Yes</p>
            <p>If this is a Living Systematic Review, is the &#x2018;living&#x2019; method appropriate and is the search schedule clearly defined and justified? (&#x2018;Living Systematic Review&#x2019; or a variation of this term should be included in the title.)</p>
            <p>Not applicable</p>
            <p>Are sufficient details of the methods and analysis provided to allow replication by others?</p>
            <p>Yes</p>
            <p>Are the conclusions drawn adequately supported by the results presented in the review?</p>
            <p>Yes</p>
            <p>Reviewer Expertise:</p>
            <p>Radiation Imaging and Dosimetry</p>
            <p>I confirm that I have read this submission and believe that I have an appropriate level of expertise to confirm that it is of an acceptable scientific standard.</p>
        </body>
    </sub-article>
    <sub-article article-type="reviewer-report" id="report268965">
        <front-stub>
            <article-id pub-id-type="doi">10.5256/f1000research.161532.r268965</article-id>
            <title-group>
                <article-title>Reviewer response for version 1</article-title>
            </title-group>
            <contrib-group>
                <contrib contrib-type="author">
                    <name>
                        <surname>Kuppusamy</surname>
                        <given-names>Thayalan</given-names>
                    </name>
                    <xref ref-type="aff" rid="r268965a1">1</xref>
                    <role>Referee</role>
                </contrib>
                <aff id="r268965a1">
                    <label>1</label>Dr Kamakshi Memorial Hospital, Chennai, Tamil Nadu, India</aff>
            </contrib-group>
            <author-notes>
                <fn fn-type="conflict">
                    <p>
                        <bold>Competing interests: </bold>No competing interests were disclosed.</p>
                </fn>
            </author-notes>
            <pub-date pub-type="epub">
                <day>15</day>
                <month>5</month>
                <year>2024</year>
            </pub-date>
            <permissions>
                <copyright-statement>Copyright: &#x00a9; 2024 Kuppusamy T</copyright-statement>
                <copyright-year>2024</copyright-year>
                <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
                    <license-p>This is an open access peer review report distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
                </license>
            </permissions>
            <related-article ext-link-type="doi" id="relatedArticleReport268965" related-article-type="peer-reviewed-article" xlink:href="10.12688/f1000research.147345.1"/>
            <custom-meta-group>
                <custom-meta>
                    <meta-name>recommendation</meta-name>
                    <meta-value>approve</meta-value>
                </custom-meta>
            </custom-meta-group>
        </front-stub>
        <body>
            <p>Questions/Comments</p>
            <p> 1.What is the estimated CT examinations number in India, including pediatric?</p>
            <p> </p>
            <p> 2. Why abdomen CT is not taken for the study since it involves larger dose variation .</p>
            <p> </p>
            <p> 3.Why phantom study is excluded,&#x00a0; it is basic method and gold standard of dose estimation?</p>
            <p> </p>
            <p> 4.Image noise (IN) depends on type of noise filters used- will all 15 articles used had&#x00a0; same noise filter?</p>
            <p> </p>
            <p> 5. Is slice thickness is considered as a parameter in deciding radiation dose?</p>
            <p> </p>
            <p> 6.The RD data and IQ parameter collected from various CT vendors shows variation, means not homogeneous? Comparing the RD with them will result a meaningful data&#x00a0; or not?</p>
            <p> Why Phillips vendor is not included since large number of installation is here in India</p>
            <p> </p>
            <p> 7.CT radiation dose and cancer risk is debatable, it can not be taken as&#x00a0; hypothesis.&#x00a0; Probability of&#x00a0; cancer&#x00a0; induction is less if the dose is &lt; 100 mSv. No CT scan offer such magnitude of radiation now&#x00a0; a days.</p>
            <p> </p>
            <p> 8.There was no mention about diagnostic reference level (DRL), especially in India.&#x00a0; Is the stated DLIR&#x00a0; brings the dose below the DRL or not ?</p>
            <p> </p>
            <p> 9. CDDI, focal spot, slice thickness, filtration (bow type filter), tube rotation time, pitch, current modulation, AEC, low dose protocol, kV, mAs, scan area&#x00a0; may differ in each CT and influence dose- all the parameter are accounted?</p>
            <p>Are the rationale for, and objectives of, the Systematic Review clearly stated?</p>
            <p>Yes</p>
            <p>Is the statistical analysis and its interpretation appropriate?</p>
            <p>Yes</p>
            <p>If this is a Living Systematic Review, is the &#x2018;living&#x2019; method appropriate and is the search schedule clearly defined and justified? (&#x2018;Living Systematic Review&#x2019; or a variation of this term should be included in the title.)</p>
            <p>Yes</p>
            <p>Are sufficient details of the methods and analysis provided to allow replication by others?</p>
            <p>Partly</p>
            <p>Are the conclusions drawn adequately supported by the results presented in the review?</p>
            <p>Yes</p>
            <p>Reviewer Expertise:</p>
            <p>Radiation physics , diagnostic radiology</p>
            <p>I confirm that I have read this submission and believe that I have an appropriate level of expertise to confirm that it is of an acceptable scientific standard.</p>
        </body>
    </sub-article>
    <sub-article article-type="reviewer-report" id="report268955">
        <front-stub>
            <article-id pub-id-type="doi">10.5256/f1000research.161532.r268955</article-id>
            <title-group>
                <article-title>Reviewer response for version 1</article-title>
            </title-group>
            <contrib-group>
                <contrib contrib-type="author">
                    <name>
                        <surname>S</surname>
                        <given-names>Dr. Tamijeselvan</given-names>
                    </name>
                    <xref ref-type="aff" rid="r268955a1">1</xref>
                    <role>Referee</role>
                </contrib>
                <aff id="r268955a1">
                    <label>1</label>College of MRIT, Mother Teresa Postgraduate and Research institute of Health sciences, Indira Nagar, Puducherry, India</aff>
            </contrib-group>
            <author-notes>
                <fn fn-type="conflict">
                    <p>
                        <bold>Competing interests: </bold>No competing interests were disclosed.</p>
                </fn>
            </author-notes>
            <pub-date pub-type="epub">
                <day>8</day>
                <month>5</month>
                <year>2024</year>
            </pub-date>
            <permissions>
                <copyright-statement>Copyright: &#x00a9; 2024 S DT</copyright-statement>
                <copyright-year>2024</copyright-year>
                <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
                    <license-p>This is an open access peer review report distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
                </license>
            </permissions>
            <related-article ext-link-type="doi" id="relatedArticleReport268955" related-article-type="peer-reviewed-article" xlink:href="10.12688/f1000research.147345.1"/>
            <custom-meta-group>
                <custom-meta>
                    <meta-name>recommendation</meta-name>
                    <meta-value>approve</meta-value>
                </custom-meta>
            </custom-meta-group>
        </front-stub>
        <body>
            <p>
                <bold>Major comments</bold>
            </p>
            <p> The review article provides comprehensive review of the &#x00a0;Deep Learning Image Reconstruction (DLIR) &#x00a0;and its application on radiation dose and image noise. This review particularly concentrating on the application &#x00a0;and outcomes in head and chest Computed Tomography examinations compared to traditional Iterative (IR) and Filtered Back Projection (FBP) techniques. In the methodology section the authors follow the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), which is an evidence-based minimum set of items for reporting in systematic reviews and meta-analyses. It has been clearly explained.</p>
            <p> In the results the author clearly explains the key outcome in related to the aim and objectives. In particular DLIR's influence on radiation dose reduction, image noise reduction, and enhancement of image quality in CT head and chest examinations were clearly explained. The discussion and conclusion effectively explain the results,</p>
            <p> 
                <bold>Minor comments</bold>
            </p>
            <p> Some more references may be added to support the review article. The article may include the data of various other anatomical part like thorax.</p>
            <p> 
                <bold>Suggestions to editor:</bold>
            </p>
            <p> On a whole , it is an excellent review article that represents a valuable contribution for the dose reduction in the &#x00a0;CT scan using proper image reconstruction technology. Also this article provides the impact of Deep Learning Image Reconstruction technology on improvement of image quality.</p>
            <p>Are the rationale for, and objectives of, the Systematic Review clearly stated?</p>
            <p>Yes</p>
            <p>Is the statistical analysis and its interpretation appropriate?</p>
            <p>Yes</p>
            <p>If this is a Living Systematic Review, is the &#x2018;living&#x2019; method appropriate and is the search schedule clearly defined and justified? (&#x2018;Living Systematic Review&#x2019; or a variation of this term should be included in the title.)</p>
            <p>Not applicable</p>
            <p>Are sufficient details of the methods and analysis provided to allow replication by others?</p>
            <p>Yes</p>
            <p>Are the conclusions drawn adequately supported by the results presented in the review?</p>
            <p>Yes</p>
            <p>Reviewer Expertise:</p>
            <p>Competency based Radiographic Education, Radiography and Imaging Technology, Image processing Techniques, Quality Assurance of Medical Imaging, Biophysics.</p>
            <p>I confirm that I have read this submission and believe that I have an appropriate level of expertise to confirm that it is of an acceptable scientific standard.</p>
        </body>
        <back>
            <ref-list>
                <title>References</title>
                <ref id="rep-ref-268955-1">
                    <label>1</label>
                    <mixed-citation publication-type="journal">
                        <person-group person-group-type="author"/>:
                        <article-title>The potential for reduced radiation dose from deep learning-based CT image reconstruction: A comparison with filtered back projection and hybrid iterative reconstruction using a phantom.</article-title>
                        <source>
                            <italic>Medicine (Baltimore)</italic>
                        </source>.<year>2021</year>;<volume>100</volume>(<issue>19</issue>) :
                        <elocation-id>10.1097/MD.0000000000025814</elocation-id>
                        <fpage>e25814</fpage>
                        <pub-id pub-id-type="pmid">34106619</pub-id>
                        <pub-id pub-id-type="doi">10.1097/MD.0000000000025814</pub-id>
                    </mixed-citation>
                </ref>
            </ref-list>
        </back>
    </sub-article>
    <sub-article article-type="reviewer-report" id="report268958">
        <front-stub>
            <article-id pub-id-type="doi">10.5256/f1000research.161532.r268958</article-id>
            <title-group>
                <article-title>Reviewer response for version 1</article-title>
            </title-group>
            <contrib-group>
                <contrib contrib-type="author">
                    <name>
                        <surname>Shetty</surname>
                        <given-names>Shashi Kumar</given-names>
                    </name>
                    <xref ref-type="aff" rid="r268958a1">1</xref>
                    <role>Referee</role>
                    <uri content-type="orcid">https://orcid.org/0000-0003-0172-0096</uri>
                </contrib>
                <aff id="r268958a1">
                    <label>1</label>NITTE university, Karnataka, India</aff>
            </contrib-group>
            <author-notes>
                <fn fn-type="conflict">
                    <p>
                        <bold>Competing interests: </bold>No competing interests were disclosed.</p>
                </fn>
            </author-notes>
            <pub-date pub-type="epub">
                <day>30</day>
                <month>4</month>
                <year>2024</year>
            </pub-date>
            <permissions>
                <copyright-statement>Copyright: &#x00a9; 2024 Shetty SK</copyright-statement>
                <copyright-year>2024</copyright-year>
                <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
                    <license-p>This is an open access peer review report distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
                </license>
            </permissions>
            <related-article ext-link-type="doi" id="relatedArticleReport268958" related-article-type="peer-reviewed-article" xlink:href="10.12688/f1000research.147345.1"/>
            <custom-meta-group>
                <custom-meta>
                    <meta-name>recommendation</meta-name>
                    <meta-value>approve</meta-value>
                </custom-meta>
            </custom-meta-group>
        </front-stub>
        <body>
            <p>
                <bold>Major comments:</bold>
            </p>
            <p> The article provides an insightful and comprehensive review of the influence of Deep Learning Image Reconstruction (DLIR) on radiation dose, image noise, and outcomes in head and chest CT examinations compared to traditional Iterative (IR) and Filtered Back Projection (FBP) techniques. The methodology section is meticulously detailed, following PRISMA guidelines. The results section offers a clear summary of the inclusion and exclusion criteria, key outcomes related to DLIR's influence on radiation dose reduction, image noise reduction, and enhancement of image quality in CT head and chest examinations. The inclusion of quality assessment scores adds validation to the review's findings. The discussion and conclusion effectively explain the results, offering potential applications of DLIR in clinical settings.&#x00a0;</p>
            <p> </p>
            <p> 
                <bold>Minor suggestions:</bold>
            </p>
            <p> Please proofread for grammatical errors. Additionally, consider including points related to the smaller sample size of pediatric CT cases to provide a more comprehensive overview.&#x00a0;</p>
            <p> </p>
            <p> 
                <bold>Suggestions to editor:</bold>
            </p>
            <p> Overall, it is an excellent review article that represents a valuable contribution to the field of CT image reconstruction technology, providing insights into the impact of Deep Learning Image Reconstruction technology on dose reduction and improvement of image quality.</p>
            <p>Are the rationale for, and objectives of, the Systematic Review clearly stated?</p>
            <p>Yes</p>
            <p>Is the statistical analysis and its interpretation appropriate?</p>
            <p>Yes</p>
            <p>If this is a Living Systematic Review, is the &#x2018;living&#x2019; method appropriate and is the search schedule clearly defined and justified? (&#x2018;Living Systematic Review&#x2019; or a variation of this term should be included in the title.)</p>
            <p>Not applicable</p>
            <p>Are sufficient details of the methods and analysis provided to allow replication by others?</p>
            <p>Yes</p>
            <p>Are the conclusions drawn adequately supported by the results presented in the review?</p>
            <p>Yes</p>
            <p>Reviewer Expertise:</p>
            <p>Radiation Biology, Radiation dose related research in CT, X-rays, Fluoroscopy etc.. Radiography.</p>
            <p>I confirm that I have read this submission and believe that I have an appropriate level of expertise to confirm that it is of an acceptable scientific standard.</p>
        </body>