<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2 20190208//EN" "http://jats.nlm.nih.gov/publishing/1.2/JATS-journalpublishing1.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="1.2" xml:lang="en">
    <front>
        <journal-meta>
            <journal-id journal-id-type="pmc">F1000Research</journal-id>
            <journal-title-group>
                <journal-title>F1000Research</journal-title>
            </journal-title-group>
            <issn pub-type="epub">2046-1402</issn>
            <publisher>
                <publisher-name>F1000 Research Limited</publisher-name>
                <publisher-loc>London, UK</publisher-loc>
            </publisher>
        </journal-meta>
        <article-meta>
            <article-id pub-id-type="doi">10.12688/f1000research.174900.1</article-id>
            <article-categories>
                <subj-group subj-group-type="heading">
                    <subject>Research Article</subject>
                </subj-group>
                <subj-group>
                    <subject>Articles</subject>
                </subj-group>
            </article-categories>
            <title-group>
                <article-title>Continuous Flow injection analysis-turbidimetric determination of Cobalt (II) ion in different alloy samples using linear array of six snow-white LEDs as a source and one solar cell as an energy transducer</article-title>
                <fn-group content-type="pub-status">
                    <fn>
                        <p>[version 1; peer review: 1 not approved]</p>
                    </fn>
                </fn-group>
            </title-group>
            <contrib-group>
                <contrib contrib-type="author" corresp="yes">
                    <name>
                        <surname>Ahmed</surname>
                        <given-names>Zainab Zahid</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Formal Analysis</role>
                    <role content-type="http://credit.niso.org/">Funding Acquisition</role>
                    <role content-type="http://credit.niso.org/">Investigation</role>
                    <role content-type="http://credit.niso.org/">Methodology</role>
                    <role content-type="http://credit.niso.org/">Software</role>
                    <uri content-type="orcid">https://orcid.org/0009-0001-9339-0639</uri>
                    <xref ref-type="corresp" rid="c1">a</xref>
                    <xref ref-type="aff" rid="a1">1</xref>
                </contrib>
                <contrib contrib-type="author" corresp="yes">
                    <name>
                        <surname>Turkey</surname>
                        <given-names>Nagham Shakir</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Conceptualization</role>
                    <role content-type="http://credit.niso.org/">Data Curation</role>
                    <role content-type="http://credit.niso.org/">Formal Analysis</role>
                    <role content-type="http://credit.niso.org/">Investigation</role>
                    <role content-type="http://credit.niso.org/">Methodology</role>
                    <role content-type="http://credit.niso.org/">Supervision</role>
                    <role content-type="http://credit.niso.org/">Validation</role>
                    <role content-type="http://credit.niso.org/">Writing &#x2013; Review &amp; Editing</role>
                    <xref ref-type="corresp" rid="c2">b</xref>
                    <xref ref-type="aff" rid="a1">1</xref>
                </contrib>
                <contrib contrib-type="author" corresp="no">
                    <name>
                        <surname>Athab</surname>
                        <given-names>Murtadha Hadi</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Software</role>
                    <role content-type="http://credit.niso.org/">Visualization</role>
                    <xref ref-type="aff" rid="a2">2</xref>
                </contrib>
                <contrib contrib-type="author" corresp="no">
                    <name>
                        <surname>Al-Yassiri</surname>
                        <given-names>Muntadar A. H.</given-names>
                    </name>
                    <role content-type="http://credit.niso.org/">Validation</role>
                    <xref ref-type="aff" rid="a1">1</xref>
                </contrib>
                <aff id="a1">
                    <label>1</label>Department of Chemistry, University of Baghdad Al-Jaderyia Campus College of Science, Baghdad, Baghdad Governorate, 10071, Iraq</aff>
                <aff id="a2">
                    <label>2</label>Department of Dentistry, AL-Mansour University College, Baghdad, Baghdad, Iraq</aff>
            </contrib-group>
            <author-notes>
                <corresp id="c1">
                    <label>a</label>
                    <email xlink:href="mailto:zainab.ahmed@sc.uobaghdad.edu.iq">zainab.ahmed@sc.uobaghdad.edu.iq</email>
                </corresp>
                <corresp id="c2">
                    <label>b</label>
                    <email xlink:href="mailto:nagam.turky@sc.uobaghdad.edu.iq">nagam.turky@sc.uobaghdad.edu.iq</email>
                </corresp>
                <fn fn-type="conflict">
                    <p>No competing interests were disclosed.</p>
                </fn>
            </author-notes>
            <pub-date pub-type="epub">
                <day>30</day>
                <month>4</month>
                <year>2026</year>
            </pub-date>
            <pub-date pub-type="collection">
                <year>2026</year>
            </pub-date>
            <volume>15</volume>
            <elocation-id>646</elocation-id>
            <history>
                <date date-type="accepted">
                    <day>13</day>
                    <month>4</month>
                    <year>2026</year>
                </date>
            </history>
            <permissions>
                <copyright-statement>Copyright: &#x00a9; 2026 Ahmed ZZ et al.</copyright-statement>
                <copyright-year>2026</copyright-year>
                <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
                    <license-p>This is an open access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
                </license>
            </permissions>
            <self-uri content-type="pdf" xlink:href="https://f1000research.com/articles/15-646/pdf"/>
            <abstract>
                <sec>
                    <title>Background</title>
                    <p>Accurate determination of cobalt (Co
                        <sup>2+</sup>) in industrial samples is essential due to its environmental and industrial significance. This work presents a fast, sensitive, and cost effective analytical method based on precipitation reaction and flow injection analysis (FIA).</p>
                </sec>
                <sec>
                    <title>Methods</title>
                    <p>Cobalt ions were estimated through the formation of a pale orange precipitate via reaction of sodium nitroprusside in acidic medium. The reaction mechanism was investigated using Fourier-transform infrared (FTIR) and UV-Vis spectroscopy. A homemade NAG-6SX1-1D analyzer, equipped with six white LEDs and a solar-cell photodetector, was utilized to measure the analytical signal. Experimental factors affecting sensitivity were systematically optimized. the method performance was evaluated in terms of linearity, accuracy, precision, and LOD, and compare with a reference UV-Vis spectrophotometric method at at &#x03bb;
                        <sub>max</sub>&#x00a0;=&#x00a0;512&#x00a0;nm.</p>
                </sec>
                <sec>
                    <title>Results</title>
                    <p>the method exhibited a good linear range of 0.005&#x2013;8&#x00a0;mmol. L
                        <sup>&#x2212;1</sup> with correlation coefficient (r) of 0.9959 and linearity (R
                        <sup>2</sup>) of 99.20%. high precision was achieved with relative standard deviation (RSD%) lower than 0.2% for the repetitions (n&#x00a0;=&#x00a0;6) were significantly at 5 and 7&#x00a0;mmol. L
                        <sup>&#x2212;1</sup>. The limit of detection (LOD) was 0.413&#x00a0;ng/sample. The use of continuous dilution in FIA enables effective handling of both diluted or concentrated samples. The proposed method showed improve performance relative to the reference method.</p>
                </sec>
                <sec>
                    <title>Conclusion</title>
                    <p>The developed method is straightforward, sensitive, and reliable for determining Co
                        <sup>2+</sup> ions in industrial samples. Its wide linear range, low detection limit, and high precision make it a practical alternative to conventional spectrophotometric methods, especially for routine and rapid analysis.</p>
                </sec>
            </abstract>
            <kwd-group kwd-group-type="author">
                <kwd>Cobalt (II)ion</kwd>
                <kwd>Spectrophotometry</kwd>
                <kwd>Turbidity</kwd>
                <kwd>Flow injection analysis &amp; Sodium nitroprusside</kwd>
            </kwd-group>
            <funding-group>
                <funding-statement>The author(s) declared that no grants were involved in supporting this work.</funding-statement>
            </funding-group>
        </article-meta>
    </front>
    <body>
        <sec id="sec5" sec-type="intro">
            <title>Introduction</title>
            <p>Cobalt is a transition metal that belongs to the Earth&#x2019;s crust and is widely used in many fields, including technology, energy and medicine.
                <sup>
                    <xref ref-type="bibr" rid="ref1">1</xref>
                </sup> It is not normally found free of its combination with other elements as a metal, but it is bound in ores usually mixed with nickel and copper.
                <sup>
                    <xref ref-type="bibr" rid="ref2">2</xref>
                </sup> In 2020, cobalt was still significantly important in the manufacturing of lithium-ion batteries for electric vehicle.
                <sup>
                    <xref ref-type="bibr" rid="ref3">3</xref>
                </sup> In 2021, the demand for cobalt continues and is steered towards green energy applications, most notably in renewable energy system including windmills and solar cells.
                <sup>
                    <xref ref-type="bibr" rid="ref4">4</xref>
                </sup> These industries require cobalt-based superalloys, magnets and other crucial materials for maximum operability.
                <sup>
                    <xref ref-type="bibr" rid="ref5">5</xref>
                </sup> Ongoing research and development efforts have directed toward searching for alternatives or reducing the cobalt content in battery systems. These improvements have been focused on improving the battery performance and reducing the dependence on cobalt because of fluctuations in the market price.
                <sup>
                    <xref ref-type="bibr" rid="ref6">6</xref>
                </sup> By 2022, battery development, (concentrating on no only lowering but also potentially eliminating cobalt) and improved energy density and performance have been targeted via solid-state and other alternative chemistries advances.
                <sup>
                    <xref ref-type="bibr" rid="ref7">7</xref>
                </sup> Currently, cobalt is used in various industrial applications, including magnetic alloys,
                <sup>
                    <xref ref-type="bibr" rid="ref8">8</xref>&#x2013;
                    <xref ref-type="bibr" rid="ref10">10</xref>
                </sup> catalysts
                <sup>
                    <xref ref-type="bibr" rid="ref11">11</xref>&#x2013;
                    <xref ref-type="bibr" rid="ref13">13</xref>
                </sup> as well as high-strength alloy selections for aviation.
                <sup>
                    <xref ref-type="bibr" rid="ref14">14</xref>
                </sup> In medicine, Co-60 is a radioactive isotope of cobalt used for medical therapies and sterilization of hospital instruments.
                <sup>
                    <xref ref-type="bibr" rid="ref15">15</xref>
                </sup>
            </p>
            <p>Several methods based on continuous flow injection analysis (FIA) have been described for the determination of various species
                <sup>
                    <xref ref-type="bibr" rid="ref16">16</xref>&#x2013;
                    <xref ref-type="bibr" rid="ref19">19</xref>
                </sup> and cobalt (II) ions along with different types techniques like Turbidimetric continuous flow injection analysis,
                <sup>
                    <xref ref-type="bibr" rid="ref20">20</xref>&#x2013;
                    <xref ref-type="bibr" rid="ref22">22</xref>
                </sup> spectrophotometry,
                <sup>
                    <xref ref-type="bibr" rid="ref23">23</xref>
                </sup> Reversed Flow Injection Spectrophotometry,
                <sup>
                    <xref ref-type="bibr" rid="ref24">24</xref>
                </sup> Microexraction-spectrophotometry
                <sup>
                    <xref ref-type="bibr" rid="ref25">25</xref>
                </sup> chemiluminescence
                <sup>
                    <xref ref-type="bibr" rid="ref26">26</xref>
                </sup> and high-performance liquid chromatography (HPLC).
                <sup>
                    <xref ref-type="bibr" rid="ref27">27</xref>
                </sup> The Flow Injection Analysis (FIA) is a versatile and powerful analytical technique, used for chemical analysis and process monitoring. The FIA approach includes a determination method in which the sample is introduced continuously into an on-line carrier stream that carries the sample to a detector for such analysis. The rapid analytical speed, low reagent consumption, and high degree of automation are some of the unique features of this method. FIA is suitable for a variety of chemical measurements such as spectrophotometry, fluorometry and electrochemistry.
                <sup>
                    <xref ref-type="bibr" rid="ref16">16</xref>&#x2013;
                    <xref ref-type="bibr" rid="ref19">19</xref>
                </sup>
            </p>
            <p>In this study, the precipitation of cobalt (II) ions was achieved using a new precipitating agent sodium nitroprusside (SNP) and reported as nitro press. This method was utilized to determine the concentrations of Co (II) ions in pure samples and alloys using a newly developed instrument (NAG-6SX1-1D Analyzer
                <sup>
                    <xref ref-type="bibr" rid="ref28">28</xref>
                </sup>), which was home-made as shown in 
                <xref ref-type="fig" rid="f1">
Figure 1</xref>. Cobalt (II) quantification was performed using this approach based on the amount of transmitted light that passed through the turbid solution. Alternatively, another procedure was carried out in which the above reaction was performed using conventional analytical techniques such as UV-spectrophotometry (&#x03bb;&#x00a0;=&#x00a0;512&#x00a0;nm). Statistical tools were used to compare the obtained results. The instrument is simple to use, has high sensitivity low detection limit as well as excellent reproducibility of the obtained results. The main goal of this research is to introduce a feasible alternative to the traditional techniques so that high accuracy and computational efficiency can be maintained.</p>
            <fig fig-type="figure" id="f1" orientation="portrait" position="float">
                <label>
Figure 1. </label>
                <caption>
                    <title>Graphical design of the whole manifold system (NAG-6SX1-1D Analyzer).</title>
                </caption>
                <graphic id="gr1" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure1.gif"/>
            </fig>
            <sec id="sec6">
                <title>Reagent and chemicals</title>
                <p>Cobaltous nitrate and nitro press (chemical formula Na
                    <sub>2</sub>[Fe (CN)
                    <sub>5</sub>NO]. 2H
                    <sub>2</sub>O), of analytical grade from Merck, and their solutions were prepared in distilled water. A 20&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> Co (NO
                    <sub>3</sub>)
                    <sub>2</sub>.6H
                    <sub>2</sub>O standard solution was added with a molecular weight of 291.04&#x00a0;g. mol
                    <sup>&#x2212;1</sup>: 1.455&#x00a0;g was dissolved in distilled water from BDH up to a total volume of 250&#x00a0;mL. Additionally, a standard nitro press solution (50&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>) was added, with a molecular weight of 298.0&#x00a0;g. mol
                    <sup>&#x2212;1</sup> from BDH was synthesized by dissolving 3.725&#x00a0;g of nitro press in 250&#x00a0;mL of distilled water. A sequence of nitro press (Fluka) solutions was synthesized by diluting a standard solution at a concentration of 50&#x00a0;mM with deionized water. Three alloy samples were prepared for the research using high-purity iron (
                    <ext-link ext-link-type="uri" xlink:href="http://B.C.S.NO">B.C.S.NO</ext-link>.260/2), high-purity iron granules (
                    <ext-link ext-link-type="uri" xlink:href="http://B.C.S.NO">B.C.S.NO</ext-link>.149/2), and high-purity copper (
                    <ext-link ext-link-type="uri" xlink:href="http://B.C.S.NO">B.C.S.NO</ext-link>.197e). Fifteen grams of each alloy was accurately weighed and transferred into a 400&#x00a0;ml beaker, followed by the introduction of a 1:1 mixture of HCl and HNO
                    <sub>3</sub>, which was then gently heated while maintaining constant agitation until all brown fumes had dissipated. The resulting solution was diluted to a final volume of 100&#x00a0;ml. The filtrate was collected after washing the filter paper multiple times, and the solution was transferred into a volumetric flask with a capacity of 100&#x00a0;ml. The flask was filled to the calibrated mark, and a series of diluted solutions were prepared.</p>
            </sec>
            <sec id="sec7">
                <title>Fourier transform infrared interpretation of the Co (II)&#x2013;nitroprusside product</title>
                <p>In the Fourier Transform Infrared (shortened in FTIR)&#x2002;spectrum of the product Co (II)&#x2013;nitroprusside their spectral features changed systematically with respect to free sodium nitroprusside, corroborating on-site molecular interactions and coordination between Co
                    <sup>2+</sup> ions and the nitroprusside ligand. As shown in 
                    <xref ref-type="fig" rid="f2">
Figure 2</xref>, the wide band between 3890 and 3430&#x00a0;cm
                    <sup>&#x2212;1</sup>, assigned to O&#x2013;H stretching modes, was also over-toned by intense and distorted bands in the product&#x2002;probably owing to hydrogen bonding by coordinated or lattice water molecules within the newly formed precipitate. The swelling of the slab is&#x2002;a sign of hydration and structural change during complex formation.</p>
                <fig fig-type="figure" id="f2" orientation="portrait" position="float">
                    <label>
Figure 2. </label>
                    <caption>
                        <title>FTIR spectra for Co (II)&#x2013;nitroprusside precipitate.</title>
                    </caption>
                    <graphic id="gr2" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure2.gif"/>
                </fig>
                <p>The &#x03bd;(C&#x00a0;&#x2261;&#x00a0;N) stretching vibrations of nitroprusside, which are typically observed as sharp single bands at ~2200&#x00a0;cm
                    <sup>&#x2212;1</sup>, were present in the product as multiple bands at 2187,&#x2002;2150 and 2090&#x00a0;cm
                    <sup>&#x2212;1</sup>; a lower frequency component was also apparent at 1957&#x00a0;cm
                    <sup>&#x2212;1</sup>. This splitting and low energy shift of the cyanide&#x2002;ion reflects electron density redistribution across the Fe&#x2013;C&#x00a0;&#x2261;&#x00a0;N motif upon coordination of Co
                    <sup>2+</sup> via a cyanide nitrogen. Such spectral shifts are characteristic of the creation of a&#x2002;bridging Co&#x2013;NC&#x2013;Fe bonds, indicating the conversion from free nitroprusside to a bimetallic complex.</p>
                <p>The nitrosyl stretching&#x2002;vibration at around 1930&#x2013;1940&#x00a0;cm
                    <sup>&#x2212;1</sup> in free (uncomplexed) nitroprusside, shifted significantly to 1616&#x00a0;cm
                    <sup>&#x2212;1</sup> in the product spectrum. Such a large shift indicates that there is also a pronounced structural rearrangement of the Fe&#x2013;NO electronic environment due to coordination-induced&#x2002;back-bonding effects. This&#x2002;is a well-known feature of metal&#x2013;nitroprusside complexation and supports the presence of Co (II)&#x2013;nitroprusside formation. The bands related to CN/NO bending and Fe&#x2013;C/Co&#x2013;N mode skeletal deformation in the range of 1357&#x00a0;cm
                    <sup>&#x2212;1</sup> and&#x2002;520&#x2013;320&#x00a0;cm
                    <sup>&#x2212;1</sup> became broader in the complex spectra. This widening indicates enhanced molecular distortion and rearrangement in the Co
                    <sup>2+</sup>&#x00a0;&#x2212;&#x00a0;coordinated&#x2002;CN/N
                    <sub>2</sub>O framework.</p>
                <p>In addition, no new functional groups were observed in the IR spectrum, suggesting that the formation of Co (II)&#x2013;nitroprusside precipitate is not associated with a chemical breakdown or covalent alteration of the nitroprusside moiety, but rather with non-covalent and coordination bonding mainly through metal-ligand bonding by cyanide nitrogen. The retention of basic bands of cyanide and nitrosyl indicates that the core of Fe (CN)
                    <sub>5</sub>NO is structurally preserved in the synthesized complex.</p>
            </sec>
            <sec id="sec8">
                <title>UV-Vis spectroscopy for Co
                    <sup>2+</sup>-nitroprusside precipitate</title>
                <p>UV-Vis spectroscopy was used to examine the electronic effects and structural changes during the formation of cobalt&#x2013;nitroprusside precipitates. The resulting solid precipitate from the reaction of cobalt nitrate with sodium nitroprusside was separated, washed with water to remove any soluble nitrates, and sonicated for spectrophotometric studies after dissolving the precipitate particles in dimethylformamide (DMF). UV&#x2013;Vis studies were carried out to monitor the electronic transitions associated with the Fe&#x2013;CN skeleton and the coordination environment of Co
                    <sup>2+</sup> during cyanide-bridged complexation.</p>
                <p>The recorded spectrum (
                    <xref ref-type="fig" rid="f3">
Figure 3</xref>) had a strong absorption at the near-UV path (280&#x00a0;&#x223c;&#x00a0;310&#x00a0;nm wavelength), with the intensity maximum located around 295&#x2013;300&#x2002;nm. This is a typical feature of ligand-to-metal charge transfer (LMCT) transitions from cyanide and nitrosyl ligands to the iron center of the nitroprusside moiety. The high-energy and narrow width of this band demonstrates the generation of a novel electronic structure produced by the incorporation of Co
                    <sup>2+</sup> ions into the Fe&#x2013;CN coordination network.</p>
                <fig fig-type="figure" id="f3" orientation="portrait" position="float">
                    <label>
Figure 3. </label>
                    <caption>
                        <title>UV-Vis spectrum of Co (II)&#x2013;nitroprusside.</title>
                    </caption>
                    <graphic id="gr3" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure3.gif"/>
                </fig>
                <p>In addition to the main LMCT band, the spectrum clearly shows a featureless absorbance decrease between 330 and 380&#x00a0;nm with a shoulder at this wavelength. This was due to perturbations involving intra-ligand (
                    <italic toggle="yes">&#x03c0;&#x00a0;&#x2192;&#x00a0;&#x03c0;*</italic>) transitions of the coordinated nitrosyl group. These perturbations result from changes in the electron density across the Fe&#x2013;NO bond upon Co
                    <sup>2+</sup> binding, suggesting partial charge redistribution and strengthening of the Fe&#x2013;CN&#x2013;Co bridging interaction. The existence of this band supports the evidence of a cyanide-mediated coupling between Fe
                    <sup>2+</sup> and Co
                    <sup>2+</sup>, as previously suggested by the mechanism.</p>
                <p>Above 400&#x00a0;nm, there is a very broad and weak tail that extends to at least 550&#x2013;600&#x2002;nm. Free hexaaquacobalt (II) ions normally show sharp d&#x2013;d transitions in this region&#x2002;; however, the near-absence of these bands in the current spectrum suggests that Co
                    <sup>2+</sup> no longer exists as an aqua-coordinated octahedral species. Instead, its electronic transitions are Laporte-forbidden and highly attenuated upon coordination with cyanides. The fact that no distinct visible-region absorptions were observed further supports the formation of a cyanide-bridged Fe&#x2013;CN&#x2013;Co complex and not just an ionic mixture of reactants.</p>
                <p>The spectral features including the strong charge-transfer band and the absence of cobalt d&#x2013;d bands are in good agreement with the proposed scheme where Co
                    <sup>2+</sup> replaces sodium counter ions and forms an inner-sphere complex with nitroprusside. The related structural motif Fe&#x2013;CN&#x2013;Co induces a modified electronic environment, which gives rise to the characteristic Fe3+ UV&#x2013;Vis fingerprint. Considering the spectroscopic results, the obtained experimental evidence unambiguously confirms the successful precipitation of cobalt&#x2013;nitroprusside and verifies that the structural rearrangement proposed in the reaction scheme occurs.</p>
            </sec>
            <sec id="sec9">
                <title>Apparatus</title>
                <p>The whole instrument
                    <sup>
                        <xref ref-type="bibr" rid="ref28">28</xref>
                    </sup> uses a linear array of irradiation sources possess a snow-white light emerging from six light-emitting diodes as shown in 
                    <xref ref-type="fig" rid="f4">
Figure 4</xref>. All these LEDs were arranged in a metal block made of brass with 20 x 20 and 60&#x00a0;cm length. The flow cell is a 70&#x00a0;mm in length made of a quartz tube with an inside diameter of a 2&#x00a0;mm and an outside diameter of 4&#x00a0;mm placed in a groove of brass metal with a channel width of 4&#x00a0;mm to enclose the flow cell in a perfect housing. Above this 4&#x00a0;mm groove, there is a channel of 14&#x00a0;mm width, 2&#x00a0;mm depth, and 60&#x00a0;mm length to form a channel to accommodate the single detector of solar cell. The solar cell detector will respond to the range of 410&#x2013;1140&#x00a0;nm; which is capable of detecting any attenuation of light from the formed precipitate particulate (i.e.; turbidity, T).</p>
                <fig fig-type="figure" id="f4" orientation="portrait" position="float">
                    <label>
Figure 4. </label>
                    <caption>
                        <title>A schematic of the NAG-6SX1-1D Analyzer which shows the geometrical arrangement of a six white snow LEDs and flow cell.</title>
                    </caption>
                    <graphic id="gr4" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure4.gif"/>
                </fig>
            </sec>
            <sec id="sec10">
                <title>Methodology</title>
                <p>Using the preliminary concentration of Co (II) (6.5&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>), which reacts with Na
                    <sub>2</sub>[Fe (CN)
                    <sub>5</sub>NO].2H
                    <sub>2</sub>O, the manifold system consists of two lines, as shown in 
                    <xref ref-type="fig" rid="f1">Figure 1</xref>. This figure shows that the Co (II) ion is determined through its reaction with the Nitro press (0.3&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>) in an acetic acid medium (7&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>), forming pale orange precipitate particles in the ion pair form. To perform this determination, a carrier stream of acetic acid was used as the first line, with a flow rate of 1.7&#x00a0;ml. min
                    <sup>&#x2212;1</sup>. Through the injection valve, a sample segment of cobalt (II) ion (6.5&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>) was introduced to meet with the Nitro press (0.3&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>) in the second line, which had the same flow rate until the Y-junction point. From there, it is introduced to the NAG-6SX1-1D Analyzer, which has six irradiation sources of snow-white light-emitting diodes located on one side, while the opposite side (facing side) at 0&#x2013;180&#x00b0; houses the solar cell.</p>
                <p>The profile Y
                    <sub>zi</sub> (mV)-t
                    <sub>min</sub> (d
                    <sub>cm</sub>) was obtained by measuring the attenuation of the energy transducer response and expressed as an average of the peak heights in mV, repeated three successive times. The use of a flow cell with different tube diameters, that is converting from internal diameters of 1&#x00a0;mm to 4&#x00a0;mm, absorbs disturbances, modifies any noise, and reduces the distance in which the segment is viewed in front of the detector, thereby increasing the sensitivity and obtaining a noise-free profile. Additionally, a larger diameter (4&#x00a0;mm) allows time for the agglomeration of the formed particles by having a short segment and a high density of the precipitate, thus increasing the sensitivity. 
                    <xref ref-type="fig" rid="f5">
Figure 5</xref> presents a proposed reaction mechanism that elucidates the interaction between the cobalt (II) ion and nitro press in an acetic acid environment.
                    <sup>
                        <xref ref-type="bibr" rid="ref22">22</xref>,
                        <xref ref-type="bibr" rid="ref23">23</xref>
                    </sup>
                </p>
                <fig fig-type="figure" id="f5" orientation="portrait" position="float">
                    <label>
Figure 5. </label>
                    <caption>
                        <title>The proposed mechanism of the precipitation reaction for Co
                            <sup>2+</sup> ion with Nitro press reagent.</title>
                    </caption>
                    <graphic id="gr5" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure5.gif"/>
                </fig>
            </sec>
            <sec id="sec11">
                <title>Optimization of chemical and physical conditions</title>
                <p>

                    <list list-type="order">
                        <list-item>
                            <label>1.</label>
                            <p>

                                <bold>Effect of variable concentrations of precipitation agents:</bold>
                            </p>
                        </list-item>
                    </list>
                </p>
                <p>A series of Nitro press solutions were prepared by diluting the original stock solution with distilled water to achieve concentrations ranging from 0.03 to 0.4&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>. Each concentration was assessed in triplicate, targeting a molarity of 6.5&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>, with a sample volume of 175&#x00a0;&#x03bc;L, using an open valve mode and a flow rate of 1.5&#x00a0;ml. min
                    <sup>&#x2212;1</sup> for both the carrier stream (distilled water) and the reagent. 
                    <xref ref-type="fig" rid="f6">
Figure 6</xref>-A illustrates the response profile of this investigation, showing that the response of the energy transducer varies with the nitro press concentration when using the NAG-6SX1-1D analyzer. The response of the colored species decreased with increasing Nitro press concentration up to 0.3&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> concentrations higher than 0.3&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> was followed by a decrease in the peak height maxima because of the agglomeration of the precipitate. Accordingly, the concentration of the nitro press 0.3&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> (
                    <xref ref-type="fig" rid="f6">
Figure 6</xref>-B) was selected as the optimal concentration for further studies.
                    <list list-type="order">
                        <list-item>
                            <label>2.</label>
                            <p>

                                <bold>Effect of using different medium as a carrier stream (salts and acids):</bold>
                            </p>
                        </list-item>
                    </list>
</p>
                <p>A series of experiments were performed with different aqueous solutions of salts and acids ((NH
                    <sub>4</sub>Cl, NaCl, Na
                    <sub>2</sub>SO
                    <sub>4</sub>, KCl, CH
                    <sub>3</sub>COONH
                    <sub>4</sub>, HCl, HNO
                    <sub>3</sub>, H
                    <sub>3</sub>PO
                    <sub>4</sub>, H
                    <sub>2</sub>SO
                    <sub>4</sub>, C
                    <sub>4</sub> H
                    <sub>6</sub>O
                    <sub>6</sub> and CH
                    <sub>3</sub>COOH)) instead of distilled water for the carrier stream. These experiments were performed to enhance the sensitivity and detection limits. The experiment was conducted with the following parameters: 6.5&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> Cobalt (II) ion concentration; both streams were passed through at a flow rate of 1.5&#x00a0;ml. min
                    <sup>&#x2212;1</sup>; sample volume, 175&#x00a0;&#x03bc;L open valve mode. The results showed a remarkable enhancement in detector sensitivity with the use of acetic acid (CH
                    <sub>3</sub>COOH) as a carrier flow. However, the detector sensitivity was decreased by the addition of other aqueous salt solutions because the precipitated particles were dispersed in the presence of salts. The precipitate particles may have been invaded by the salts and subjected to disintegration. Some acids can also dissolve precipitates owing to their respective negative ions or chemical nature. Therefore, acetic acid (CH
                    <sub>3</sub>COOH) has been selected as the best carrier stream (
                    <xref ref-type="fig" rid="f7">
Figures 7</xref> -A and B).</p>
                <fig fig-type="figure" id="f6" orientation="portrait" position="float">
                    <label>
Figure 6. </label>
                    <caption>
                        <title>A- Variation effect of Nitro press on profile &#x2013; time (min), B- Optimum of [Nitro press]&#x00a0;=&#x00a0;0.3&#x00a0;mmol/L.</title>
                    </caption>
                    <graphic id="gr6" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure6.gif"/>
                </fig>
                <fig fig-type="figure" id="f7" orientation="portrait" position="float">
                    <label>
Figure 7. </label>
                    <caption>
                        <title>Flow chart presents the effect of using different media (acids(A) and salts(B)) in the reaction between cobalt (II) ion and nitro press.</title>
                    </caption>
                    <graphic id="gr7" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure7.gif"/>
                </fig>
                <p>The optimal concentration of acetic acid as the carrier stream was 3&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>, which was confirmed by the preparation of different solutions (1&#x2013;15&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>). The sample volume was 175&#x00a0;&#x03bc;L and the flow rate 1.5&#x00a0;ml. min
                    <sup>&#x2212;1</sup>, an open valve configuration, and a reagent concentration (Nitro press) of 0.3&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> provided the initial cobalt (II) ion concentration of 6.5&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>. All experimental trials were performed in triplicate, which resulted in observed larger attenuation of the incident light at higher concentration of CH
                    <sub>3</sub>COOH. This is also thoughts to be due to the small size of the precipitate particles, particularly when these are formed in a nucleation and growth mode and tend to aggregate in a close packed configuration, promoting agglomeration. Subsequently, as the concentration was increased to 7&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> and beyond, the attenuation of the incident light was further increased up to 7&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> owing to the enhancement by larger particles, which shows higher solubility for smaller-sized particles. In addition, high acid levels might cause the precipitate particles to be disrupted and degrade to form smaller pieces that do not scatter the incident light efficiently. The optimal carrier stream was determined to be 7&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> of CH
                    <sub>3</sub>COOH. The results are shown in 
                    <xref ref-type="fig" rid="f8">
Figure 8</xref>.
                    <list list-type="order">
                        <list-item>
                            <label>3.</label>
                            <p>

                                <bold>Study the variable of flow rates:</bold> To determine the optimal flow rate for both the reagent and carrier stream (acetic acid) line containing 6.5&#x00a0;mmol. L
                                <sup>&#x2212;1</sup> cobalt nitrate, and a range of flow rates (0.7&#x2013;2.0&#x00a0;ml. min
                                <sup>&#x2212;1</sup>) was applied to both the lines. Other experimental parameters, such as the Co
                                <sup>2+</sup> concentration (6.5&#x00a0;mmol. L
                                <sup>&#x2212;1</sup>), nitro press concentration (0.3&#x00a0;mmol. L
                                <sup>&#x2212;1</sup>), and 7&#x00a0;mmol. L
                                <sup>&#x2212;1</sup> of CH
                                <sub>3</sub>COOH, and the injection valve remained open until the measurement was completed.</p>
                        </list-item>
                    </list>
                </p>
                <fig fig-type="figure" id="f8" orientation="portrait" position="float">
                    <label>
Figure 8. </label>
                    <caption>
                        <title>Optimal Acetic Acid Concentration for Maximum Sensitivity (7&#x00a0;mmol. L
                            <sup>&#x2212;1</sup>).</title>
                    </caption>
                    <graphic id="gr8" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure8.gif"/>
                </fig>
                <p>Sensitivity was evaluated based on the height and shape of the response obtained by measuring the capability of the precipitate of the particles to attenuate light from six irradiation sources. At lower flow rates, the response time &#x0394;t
                    <sub>B</sub> increased, correlating with a significant deformation of the apex of the maximum peak response, as shown in 
                    <xref ref-type="fig" rid="f9">
Figure 9</xref>-A&amp;B. This may be ascribed to an increase in the dispersion factor, which promotes dispersion by means of spreading or penetration. Moreover, the peak height decreased apparently at 1.7&#x00a0;mL.min
                    <sup>&#x2212;1</sup>, that may be due to dilution and dispersion, resulting in an anomalous response curve. The optimum flow rate for the Co
                    <sup>2+</sup>&#x00a0;&#x2212;&#x00a0;Nitro press system was thus confirmed to be 1.7&#x00a0;mL. min
                    <sup>&#x2212;1</sup>.
                    <list list-type="order">
                        <list-item>
                            <label>4.</label>
                            <p>

                                <bold>Effect of sample volume:</bold> In this investigation, the sample volumes were varied between 25 and 215&#x00a0;&#x03bc;L, using Teflon tubes that ranged from 3.18 to 27.39&#x00a0;cm in length, with a diameter of 1&#x00a0;mm. The results showed a significant increase in peak height with increasing sample volume, reaching a maximum at 175&#x00a0;&#x03bc;L. At this volume, the peak height was highest, corresponding to a sample segment length of 22.29&#x00a0;cm. Therefore, a sample volume of 175&#x00a0;&#x03bc;L was identified as the optimal volume and will be used in future experiments, as shown in 
                                <xref ref-type="fig" rid="f10">
Figure 10</xref>.</p>
                        </list-item>
                        <list-item>
                            <label>5.</label>
                            <p>

                                <bold>The effect of delay reaction coil:</bold> To determine whether the flow system requires a mixing coil to achieve optimal reactions between the cobalt ion and nitro press, various mixing coils (made from Teflon, with an inner diameter of 1&#x00a0;mm) of different lengths (10, 20, 25, and 30&#x00a0;cm) were used under optimized conditions. As shown in 
                                <xref ref-type="fig" rid="f11">
Figure 11</xref>, the effect of the reaction coil length on the sensitivity was evaluated using the S/N energy transducer response. Despite the increase in the reaction coil length, there was no clear increase in sensitivity (i.e., the profile remained unchanged) through the rise in the response amplitude up to 785&#x00a0;&#x03bc;L, likely due to the complete mixing and reaction at this coil length. A volume exceeding 785&#x00a0;&#x03bc;L led to a decrease in peak height and a widening of the base width (&#x0394;t
                                <sub>B</sub>), likely due to the prolonged duration of the presence of precipitate particles near the detector.</p>
                        </list-item>
                    </list>
                </p>
                <fig fig-type="figure" id="f9" orientation="portrait" position="float">
                    <label>
Figure 9. </label>
                    <caption>
                        <title>Variation effect of flow rate on: A) Profile -time (min), B) Optimal flow rate for maximum sensitivity.</title>
                    </caption>
                    <graphic id="gr9" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure9.gif"/>
                </fig>
                <fig fig-type="figure" id="f10" orientation="portrait" position="float">
                    <label>
Figure 10. </label>
                    <caption>
                        <title>Effect of sample segment on signal output and determination of optimal sample volume for maximum sensitivity.</title>
                    </caption>
                    <graphic id="gr10" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure10.gif"/>
                </fig>
                <fig fig-type="figure" id="f11" orientation="portrait" position="float">
                    <label>
Figure 11. </label>
                    <caption>
                        <title>Effect of reaction coil on A) Profile, B) Output of signal in mV and determination of optimal reaction coil.</title>
                    </caption>
                    <graphic id="gr11" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure11.gif"/>
                </fig>
            </sec>
        </sec>
        <sec id="sec12" sec-type="results|discussions">
            <title>Results and discussions</title>
            <sec id="sec13">
                <title>Scatter plot for the variation of S/N &#x2013; response of the energy transducer response (S/N) versus concentration of Co (II) using the system of: Co (II)- Na
                    <sub>2</sub>[Fe (CN)
                    <sub>5</sub> NO] (0.3&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>) &#x2013; H
                    <sub>3</sub>O
                    <sup>+</sup> (7&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>)</title>
                <p>This newly developed methodology was used to measure the concentration of a chemical substance in an unknown sample by comparing it with a series of known concentrations. Using all the optimized analytical parameters of the proposed method, a calibration curve was created by recording the peak heights of the attenuated light for variable concentrations of Co (II) ion (0.005&#x2013;10&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>). The linear part of the curve for Co (II) ion is shown within the concentration range of 0.005&#x2013;8&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>, with a correlation coefficient (r) of 0.9959 (R
                    <sup>2</sup>%&#x00a0;=&#x00a0;99.20%), as shown in 
                    <xref ref-type="fig" rid="f12">
Figure 12</xref>, it is observed that there is A direct relationship was observed between the increase in signal output and the increase in concentration, likely due to the increase in precipitate particles and their aggregation, providing solid surfaces capable of attenuating the incident light up to 8&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>. Beyond this concentration, only a slight increase in the signal output was observed, which did not correspond with the higher concentration, resulting in a decrease in the correlation coefficient to 0.9897 (R
                    <sup>2</sup>%&#x00a0;=&#x00a0;97.94%).</p>
                <fig fig-type="figure" id="f12" orientation="portrait" position="float">
                    <label>
Figure 12. </label>
                    <caption>
                        <title>The calibration curve for Co (II) ion - Na
                            <sub>2</sub> [Fe (CN)
                            <sub>5</sub> NO] (0.3&#x00a0;mmol. L
                            <sup>&#x2212;1</sup>) system using newly developed tool NAG-6SX1-1D Analyzer.</title>
                        <p>&#x1fe9;
                            <sub>

                                <italic toggle="yes">&#x01b5;i(mV)</italic>
                            </sub>: Analyzer response expressed as an average (n&#x00a0;=&#x00a0;3) peak height in mV.</p>
                    </caption>
                    <graphic id="gr12" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure12.gif"/>
                </fig>
                <p>
                    <xref ref-type="table" rid="T1">
Table 1</xref> provides a comprehensive summary of the linear regression analysis results.</p>
                <table-wrap id="T1" orientation="portrait" position="float">
                    <label>
Table 1. </label>
                    <caption>
                        <title>The summary of linear regression of the proposed method and classical method.</title>
                    </caption>
                    <table content-type="article-table" frame="hsides">
                        <thead>
                            <tr>
                                <th align="left" colspan="1" rowspan="3" valign="top">Type of mode</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">
Range of [Co (II)] mmol/L (n)</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">&#x0176;
                                    <sub>zi</sub>&#x00a0;=&#x00a0;a&#x00a0;&#x00b1;&#x00a0;S
                                    <sub>a</sub>t&#x00a0;+&#x00a0;b(&#x2206;y;/&#x2206;x
                                    <sub>mmol/L</sub>)&#x00a0;&#x00b1;&#x00a0;S
                                    <sub>b</sub>t [Co (II)] mmol/L at confidence level 95%, n-2</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">
r, r,
                                    <sup>2</sup> R
                                    <sup>2</sup> %</th>
                            </tr>
                            <tr>
                                <th align="left" colspan="3" rowspan="1" valign="top">Developed method NAG-6SX1-1D Analyzer</th>
                            </tr>
                            <tr>
                                <th align="left" colspan="3" rowspan="1" valign="top">UV Spectrometer with a Maximum Wavelength of 512&#x00a0;nm</th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr>
                                <td align="left" colspan="1" rowspan="2" valign="top">Linear range or linear dynamic range</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.005&#x2013;8 (16)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">53.259&#x00a0;&#x00b1;&#x00a0;1.823&#x00a0;+&#x00a0;434.979&#x00a0;&#x00b1;&#x00a0;4.523 [Co (II)] mmol. L
                                    <sup>&#x2212;1</sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.9959
                                    <break/>0.9920
                                    <break/>99.20%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.05&#x2013;1.7 (17)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">&#x2212;0.0119&#x00a0;&#x00b1;&#x00a0;0.002&#x00a0;+&#x00a0;0.7231&#x00a0;&#x00b1;&#x00a0;0.0248 [Co (II)] mmol. L
                                    <sup>&#x2212;1</sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.9982
                                    <break/>0.9965
                                    <break/>99.65%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="2" valign="top">Scatter plot</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.005&#x2013;10 (18)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">150.973&#x00a0;&#x00b1;&#x00a0;2.482&#x00a0;+&#x00a0;402.933&#x00a0;&#x00b1;&#x00a0;8.532 [Co (II)] mmol. L
                                    <sup>&#x2212;1</sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.9897
                                    <break/>0.9794
                                    <break/>97.94%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.05&#x2013;3 (22)</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.0632&#x00a0;&#x00b1;&#x00a0;0.0024&#x00a0;+&#x00a0;0.6179&#x00a0;&#x00b1;&#x00a0;0.0232 [Co (II)] mmol. L
                                    <sup>&#x2212;1</sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.9799
                                    <break/>0.9602
                                    <break/>96.02%</td>
                            </tr>
                        </tbody>
                    </table>
                </table-wrap>
                <p>The new approach the NAG-6SX1-1D Analyzer of the determination of the Co (II) ion based on the method, was systematically compared with the conventional methodology, which involves UV-Spectroscopic technique at 512&#x00a0;nm in Co (II)- Na
                    <sub>2</sub>[Fe (CN)
                    <sub>5</sub> NO] (0.3&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>) &#x2013; H
                    <sub>3</sub>O
                    <sup>+</sup> (7&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>). This well-established approach based on the optimal determination of absorbance detects the linearity in the concentration range between 0.05 and 3&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> and is commonly accepted as a reference method 
                    <bold>(</bold>
                    <xref ref-type="fig" rid="f13">
Figure 13</xref>
                    <bold>)</bold>. The linear area of the analyte was found to be at 0.05&#x2013;1.7&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> with correlation coefficient (r) of 0.9982 and r
                    <sup>2</sup>&#x00a0;=&#x00a0;0.9965 under the optimized conditions (derived from 17 measurements). 
                    <xref ref-type="table" rid="T1">
Table 1</xref> provides a complete overview of the results.</p>
                <fig fig-type="figure" id="f13" orientation="portrait" position="float">
                    <label>
Figure 13. </label>
                    <caption>
                        <title>The calibration curve for the determination of Co (II) ion at a wavelength of 512&#x00a0;nm using UV-Vis spectroscopy.</title>
                    </caption>
                    <graphic id="gr13" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure13.gif"/>
                </fig>
            </sec>
            <sec id="sec14">
                <title>Limit of Detection (LOD)</title>
                <p>Three methods were used to examine the detection limit of Co
                    <sup>2+</sup> ions, and the overall findings are summarized in 
                    <xref ref-type="table" rid="T2">
Table 2</xref>, for an injected sample volume of 175&#x00a0;&#x03bc;L. The L.O.D were calculated and the difference, the UV-Spectroscopy data results were 47.146&#x00a0;mg/Sample.</p>
                <table-wrap id="T2" orientation="portrait" position="float">
                    <label>
Table 2. </label>
                    <caption>
                        <title>Detection limits of Co (II) ion using 175&#x00a0;&#x03bc;L as an injection sample volume of Co (II) ion -Na
                            <sub>2</sub>[Fe (CN)
                            <sub>5</sub> NO] (0.3&#x00a0;mmol. L
                            <sup>&#x2212;1</sup>) system.</title>
                    </caption>
                    <table content-type="article-table" frame="hsides">
                        <thead>
                            <tr>
                                <th align="left" colspan="2" rowspan="1" valign="top">Practically derived from the progressive attenuation of the least amount of concentration in the scatter plot</th>
                                <th align="left" colspan="1" rowspan="2" valign="top">
Theoretical based on the value of slope x&#x00a0;=&#x00a0;3S
                                    <sub>B</sub>/slope</th>
                                <th align="left" colspan="1" rowspan="2" valign="top">
Theoretical based on the linear equation &#x0176;&#x00a0;=&#x00a0;Y
                                    <sub>b</sub>&#x00a0;+&#x00a0;3Sb</th>
                                <th align="left" colspan="1" rowspan="2" valign="top">
Limit of quantitative L.O. Q &#x0176;&#x00a0;=&#x00a0;Y
                                    <sub>b</sub>&#x00a0;+&#x00a0;10S
                                    <sub>b</sub>
                                </th>
                            </tr>
                            <tr>
                                <th align="left" colspan="1" rowspan="1" valign="top">
NAG-6SX1-1D Analyzer (4&#x00a0;&#x03bc;mol/L)</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">
UV-Spectrophotometer</th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr>
                                <td align="center" colspan="1" rowspan="1" valign="top">0.413&#x00a0;ng/Sample</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">47.146&#x00a0;mg/Sample</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">50.328&#x00a0;&#x03bc;g/Sample</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">7.493&#x00a0;&#x03bc;g/Sample</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">24.973&#x00a0;&#x03bc;g/Sample</td>
                            </tr>
                        </tbody>
                    </table>
                </table-wrap>
            </sec>
            <sec id="sec15">
                <title>Repeatability</title>
                <p>The repeatability was expressed as a percent relative standard deviation when six measurements were performed in six successive injections. They focused on the two concentrations of Co
                    <sup>2+</sup> ions, which were expressed in 5&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> and 7&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> in the best experimental conditions. 
                    <xref ref-type="fig" rid="f14">
Figure 14</xref> shows the repeatability of as the data profile a perfect classification of the results and a minimum percent relative standard deviation of 0.21%.</p>
                <fig fig-type="figure" id="f14" orientation="portrait" position="float">
                    <label>
Figure 14. </label>
                    <caption>
                        <title>S/N transducer profile of six successive measurements with a repeatability of response for 5&#x00a0;mmol.L
                            <sup>&#x2212;1</sup> and 7&#x00a0;mmol/L concentration of [Co (II)] ion using Na
                            <sub>2</sub>[Fe (CN)
                            <sub>5</sub> NO] (0.3&#x00a0;mmol. L
                            <sup>&#x2212;1</sup>) &#x2013; H
                            <sub>3</sub>O
                            <sup>+</sup> (7&#x00a0;mmol.L
                            <sup>&#x2212;1</sup>) system.</title>
                    </caption>
                    <graphic id="gr14" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure14.gif"/>
                </fig>
            </sec>
            <sec id="sec16">
                <title>Assessment of Cobalt (II) ions in various alloy specimens employing a singular solar cell integrated with six distinct irradiation sources</title>
                <p>A recently established analytical methodology (NAG-6SX1-1D Analyzer) was employed for the quantification of Co (II) ions across three distinct alloys: high purity iron (
                    <ext-link ext-link-type="uri" xlink:href="http://B.C.S.NO">B.C.S.NO</ext-link>.260/2)-0.009%, High purity iron (
                    <ext-link ext-link-type="uri" xlink:href="http://B.C.S.NO">B.C.S.NO</ext-link>.149/2)-0.012%, and High purity copper (
                    <ext-link ext-link-type="uri" xlink:href="http://B.C.S.NO">B.C.S.NO</ext-link>.197e)-0.017%. The multitude flow injection apparatus is interfaced with the NAG-6SX1-1D Analyzer to monitor the transit of precipitate particles through a micro flow cell measuring 55&#x00a0;mm in length, which was subjected to six radiation sources and a single solar cell used as a detection device. The methodology is predicated on the assessment of the attenuation of incident light by the pale orange precipitate particles resulting from the interaction of the Co (II) ion with Na
                    <sub>2</sub>[Fe (CN)
                    <sub>5</sub> NO]. This approach was juxtaposed with the traditional UV-Spectroscopic method through the evaluation of absorbance at &#x03bb;
                    <sub>max</sub>&#x00a0;=&#x00a0;512&#x00a0;nm.</p>
                <p>A series of solutions were meticulously prepared for each alloy (0.2&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>) by transferring 5,3.75 and 2.65&#x00a0;mL, respectively, from each of three alloys to the five volumetric flasks (10&#x00a0;mL) followed by the increment of 0.0, 0.25, 0.5, 0.75, and 1&#x00a0;mL from a 40&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> standard solution, thereby achieving concentrations of 0, 1, 2, 3, and 4&#x00a0;mmol/L for the newly developed methodology as depicted in 
                    <xref ref-type="fig" rid="f12">
Figure 12</xref>. In contrast, the UV-Spectrophotometric method involved employing the same volumes used in the developed method but with varying amounts of the standard material. Specifically, 0, 0.125, 0.15, 0.175, and 0.2&#x00a0;mL of a 40&#x00a0;mmol. L
                    <sup>&#x2212;1</sup> standard solution of Co (II) ion were added to yield concentrations of 0, 0.5, 0.6, 0.7, and 0.8&#x00a0;mmol. L
                    <sup>&#x2212;1</sup>, respectively. Measurements were performed using both methodologies. 
                    <xref ref-type="table" rid="T3">
Table 3</xref> presents a mathematically processed analysis of the results obtained using the standard addition method (the responses for this study are illustrated in 
                    <xref ref-type="fig" rid="f12">
Figure 12</xref>). This table also includes the outcomes from the two approaches, demonstrating the practical content of the active ingredient at a 95% confidence level, the determination efficiency, and the t-test results for comparative analysis across two distinct treatment modalities.
                    <list list-type="bullet">
                        <list-item>
                            <label>-</label>
                            <p>

                                <bold>First test</bold>: Comparison between quoted value (&#x03bc;&#x00a0;=&#x00a0;9, 12 and 17&#x00a0;mg) and the mean value of the developed method (NAG-SSP Analyzer) (
                                <inline-formula>

                                    <mml:math display="inline">
                                        <mml:mover accent="true">
                                            <mml:mi mathvariant="normal">W</mml:mi>
                                            <mml:mo stretchy="true">&#x00af;</mml:mo>
                                        </mml:mover>
                                    </mml:math>
</inline-formula>
                                <sub>i(mg)</sub>). The proposed hypothesis: H
                                <sub>o</sub>: &#x03bc; = 
                                <inline-formula>

                                    <mml:math display="inline">
                                        <mml:mover accent="true">
                                            <mml:mi mathvariant="normal">W</mml:mi>
                                            <mml:mo stretchy="true">&#x00af;</mml:mo>
                                        </mml:mover>
                                    </mml:math>
</inline-formula>
                                <sub>i(mg)</sub> (i.e., the mean of any alloy that is accepted against H
                                <sub>1</sub>: &#x03bc; &#x2260; 
                                <inline-formula>

                                    <mml:math display="inline">
                                        <mml:mover accent="true">
                                            <mml:mi mathvariant="normal">W</mml:mi>
                                            <mml:mo stretchy="true">&#x00af;</mml:mo>
                                        </mml:mover>
                                    </mml:math>
</inline-formula>
                                <sub>i(mg)</sub>, due to t
                                <sub>tab</sub>(4.303) is more than t
                                <sub>value</sub> for alloys 
                                <bold>(</bold>
                                <xref ref-type="table" rid="T3">
Table 3</xref>), &#x201c;Therefore, the null hypothesis is accepted, and the alternative is rejected, indicating that there is no significant difference between the theoretical value and the mean of the observed values.&#x201d;</p>
                        </list-item>
                        <list-item>
                            <label>-</label>
                            <p>

                                <bold>Second test</bold>: Comparison of the results obtained from both methods, neglecting the difference of alloy origin and companies.</p>
                        </list-item>
                    </list>
                </p>
                <table-wrap id="T3" orientation="portrait" position="float">
                    <label>
Table 3. </label>
                    <caption>
                        <title>Summary of results: practical content, (Rec %) efficiency for the determination of Co
                            <sup>2+</sup> in three alloy samples and the results were compared using one traditional method of UV- Spectrophotometer.</title>
                    </caption>
                    <table content-type="article-table" frame="hsides">
                        <thead>
                            <tr>
                                <th align="left" colspan="1" rowspan="5" valign="top">
No. of sample</th>
                                <th align="left" colspan="1" rowspan="5" valign="top">
Type of Alloy and content</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">
Weight of Co
                                    <sup>2+</sup> in 100 gm of each alloy (gm)</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">
Equation of standard addition at 95% for n-2</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">
Practical concentration (mmol. L
                                    <sup>&#x2212;1</sup>) in 10&#x00a0;ml</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">
Weight of Co
                                    <sup>2+</sup> in each sample (100&#x00a0;g) 
                                    <inline-formula>

                                        <mml:math display="inline">
                                            <mml:mover accent="true">
                                                <mml:mi mathvariant="bold">W</mml:mi>
                                                <mml:mo stretchy="true">&#x00af;</mml:mo>
                                            </mml:mover>
                                        </mml:math>
</inline-formula>
                                    <sub>i(mg)</sub>
                                </th>
                            </tr>
                            <tr>
                                <th align="left" colspan="1" rowspan="1" valign="top">
Weight of Co
                                    <sup>2+</sup> in 15 gm of each alloy (mg)</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">&#x0176;
                                    <sub>i</sub>&#x00a0;=&#x00a0;a&#x00a0;&#x00b1;&#x00a0;s
                                    <sub>a</sub>t&#x00a0;+&#x00a0;b&#x00a0;&#x00b1;&#x00a0;s
                                    <sub>b</sub>t [Co
                                    <sup>2+</sup>] mmol. L
                                    <sup>&#x2212;1</sup>
                                </th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Practical concentration (mmol. L
                                    <sup>&#x2212;1</sup>) in 100&#x00a0;ml</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Efficiency of determination Rec.%</th>
                            </tr>
                            <tr>
                                <th colspan="1" rowspan="1">
[Co
                                    <sup>2+</sup>] mmol. L
                                    <sup>&#x2212;1</sup> of 15 gm alloy</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">r, r,
                                    <sup>2</sup> R
                                    <sup>2</sup>%</th>
                                <th align="left" colspan="1" rowspan="1" valign="top">
Practical weight of Co (II) in 15 gm 
                                    <inline-formula>

                                        <mml:math display="inline">
                                            <mml:mover accent="true">
                                                <mml:mi mathvariant="normal">W</mml:mi>
                                                <mml:mo stretchy="true">&#x00af;</mml:mo>
                                            </mml:mover>
                                        </mml:math>
</inline-formula>
                                    <sub>i(mg)</sub>
                                </th>
                                <th align="left" colspan="1" rowspan="1" valign="top">Individual t-test between claimed value &amp; practical value by new method (
                                    <inline-formula>

                                        <mml:math display="inline">
                                            <mml:mover accent="true">
                                                <mml:mi mathvariant="normal">W</mml:mi>
                                                <mml:mo stretchy="true">&#x00af;</mml:mo>
                                            </mml:mover>
                                        </mml:math>
</inline-formula>
                                    <sub>i(mg)</sub>-&#x03bc;) &#x221a;n /&#x03c3; n-1</th>
                            </tr>
                            <tr>
                                <th align="left" colspan="4" rowspan="1" valign="top">Developed method using NAG &#x2013; SSP Analyzer (mV)</th>
                            </tr>
                            <tr>
                                <th align="left" colspan="4" rowspan="1" valign="top">UV- Spectrophotometer at &#x03bb; 
                                    <sub>max</sub>&#x00a0;=&#x00a0;512&#x00a0;nm.</th>
                            </tr>
                        </thead>
                        <tbody>
                            <tr>
                                <td align="left" colspan="1" rowspan="7" valign="top">1</td>
                                <td align="left" colspan="1" rowspan="7" valign="top">
                                    <bold>(High purity iron (</bold>

                                    <ext-link ext-link-type="uri" xlink:href="http://B.C.S.No">

                                        <bold>B.C.S.No</bold>
</ext-link>

                                    <bold>.260/2) 0.009%</bold>
</td>
                                <td align="left" colspan="1" rowspan="3" valign="top">
                                    <bold>0.009</bold>

                                    <break/>

                                    <bold>9&#x00a0;mg</bold>
</td>
                                <td align="left" colspan="1" rowspan="2" valign="top">
                                    <bold>

                                        <italic toggle="yes">44.2&#x00a0;&#x00b1;&#x00a0;1.073&#x00a0;+&#x00a0;389.90&#x00a0;&#x00b1;&#x00a0;10.321 [Co (II)] mmol. L</italic>
</bold>
                                    <sup>

                                        <bold>

                                            <italic toggle="yes">&#x2212;1</italic>
</bold>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">
                                    <bold>0.1134</bold>
</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">
                                    <bold>8.90667</bold>
</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.2267</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">98.96%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.9995,0.9991, 99.91%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">1.336</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">/&#x2212; 1.816/ &lt; 4.303</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">1.35</td>
                                <td align="left" colspan="1" rowspan="3" valign="top">
                                    <bold>

                                        <italic toggle="yes">0.1223&#x00a0;&#x00b1;&#x00a0;0.0173&#x00a0;+&#x00a0;1.114&#x00a0;&#x00b1;&#x00a0;0.121 [Co (II)] mmol. L</italic>
</bold>
                                    <sup>

                                        <bold>

                                            <italic toggle="yes">&#x2212;1</italic>
</bold>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.1097</td>
                                <td align="left" colspan="1" rowspan="3" valign="top">8.6271</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="3" valign="top">0.2291</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.2195</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="2" valign="top">1.2941</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.9999, 0.9999, 99.99%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">95.86%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="8" valign="top">2</td>
                                <td align="left" colspan="1" rowspan="8" valign="top">
                                    <bold>(High purity iron (</bold>

                                    <ext-link ext-link-type="uri" xlink:href="http://B.C.S.No">

                                        <bold>B.C.S.No</bold>
</ext-link>

                                    <bold>.149/2)) 0.012%</bold>
</td>
                                <td align="left" colspan="1" rowspan="4" valign="top">0.012
                                    <break/>12&#x00a0;mg</td>
                                <td align="left" colspan="1" rowspan="3" valign="top">
                                    <bold>

                                        <italic toggle="yes">48.2&#x00a0;&#x00b1;&#x00a0;1.134&#x00a0;+&#x00a0;432.20&#x00a0;&#x00b1;&#x00a0;8.326 [Co (II)] mmol. L</italic>
</bold>
                                    <sup>

                                        <bold>

                                            <italic toggle="yes">&#x2212;1</italic>
</bold>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.1115</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">11.684</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.29739</td>
                                <td align="left" colspan="1" rowspan="2" valign="top">97.37%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="2" valign="top">1.7526</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.9903, 0.9967, 99.67%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">/&#x2212; 1.325/ &lt; 4.303</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="3" valign="top">1.8</td>
                                <td align="left" colspan="1" rowspan="3" valign="top">
                                    <bold>

                                        <italic toggle="yes">0.0980&#x00a0;&#x00b1;&#x00a0;0.0079&#x00a0;+&#x00a0;0.8345&#x00a0;&#x00b1;&#x00a0;0.094 [Co (II)] mmol. L</italic>
</bold>
                                    <sup>

                                        <bold>

                                            <italic toggle="yes">&#x2212;1</italic>
</bold>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.1175</td>
                                <td align="left" colspan="1" rowspan="3" valign="top">12.308</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.31328</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="2" valign="top">1.8463</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.3054</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.9988, 0.9975, 99.75%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">102.57%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="8" valign="top">3</td>
                                <td align="left" colspan="1" rowspan="8" valign="top">
                                    <bold>(High purity copper (</bold>

                                    <ext-link ext-link-type="uri" xlink:href="http://B.C.S.No">

                                        <bold>B.C.S.No</bold>
</ext-link>

                                    <bold>.197e) 0.017%</bold>
</td>
                                <td align="left" colspan="1" rowspan="4" valign="top">0.017
                                    <break/>17&#x00a0;mg</td>
                                <td align="left" colspan="1" rowspan="3" valign="top">
                                    <bold>

                                        <italic toggle="yes">57.6&#x00a0;&#x00b1;&#x00a0;2.104&#x00a0;+&#x00a0;509.70&#x00a0;&#x00b1;&#x00a0;9.806 [Co (II)] mmol. L</italic>
</bold>
                                    <sup>

                                        <bold>

                                            <italic toggle="yes">&#x2212;1</italic>
</bold>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.113</td>
                                <td align="left" colspan="1" rowspan="2" valign="top">16.754</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.426</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="2" valign="top">2.513</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">98.56%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.9999, 0.9998, 99.98%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">/&#x2212; 1.692/ &lt; 4.303</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="3" valign="top">2.55</td>
                                <td align="left" colspan="1" rowspan="3" valign="top">
                                    <bold>

                                        <italic toggle="yes">0.1287&#x00a0;&#x00b1;&#x00a0;0.0131&#x00a0;+&#x00a0;1.18438&#x00a0;&#x00b1;&#x00a0;0.043 [Co (II)] mmol. L</italic>
</bold>
                                    <sup>

                                        <bold>

                                            <italic toggle="yes">&#x2212;1</italic>
</bold>
                                    </sup>
                                </td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.10868</td>
                                <td align="left" colspan="1" rowspan="3" valign="top">16.1132</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.41012</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="2" valign="top">2.41698</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.1147</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">0.9993, 0.9985, 99.85%</td>
                                <td align="left" colspan="1" rowspan="1" valign="top">94.78%</td>
                            </tr>
                            <tr>
                                <td align="left" colspan="3" rowspan="1" valign="top">Paired t &#x2013;test Compared between two methods t
                                    <sub>cal</sub>= 
                                    <inline-formula>

                                        <mml:math display="inline">
                                            <mml:mover accent="true">
                                                <mml:mi mathvariant="bold">W</mml:mi>
                                                <mml:mo stretchy="true">&#x00af;</mml:mo>
                                            </mml:mover>
                                        </mml:math>
</inline-formula>d
                                    <sub>(mg)</sub> &#x221a;n/Sd</td>
                                <td align="left" colspan="3" rowspan="1" valign="top">
                                    <inline-formula>

                                        <mml:math display="inline">
                                            <mml:mover accent="true">
                                                <mml:mi mathvariant="bold">W</mml:mi>
                                                <mml:mo stretchy="true">&#x00af;</mml:mo>
                                            </mml:mover>
                                        </mml:math>
</inline-formula>

                                    <bold>d</bold>
                                    <sub>

                                        <bold>(mg)</bold>
                                    </sub>&#x00a0;=&#x00a0;0.099, Sd&#x00a0;=&#x00a0;0.6516, 
                                    <bold>t</bold>
                                    <sub>

                                        <bold>cal</bold>
                                    </sub> (0.263)&#x00a0;&lt;&#x00a0;
                                    <bold>t</bold>
                                    <sub>

                                        <bold>tab</bold>
                                    </sub>(4.303)</td>
                            </tr>
                        </tbody>
                    </table>
                </table-wrap>
                <p>The proposed hypothesis for the method is as follows:</p>
                <p>Null hypothesis 
                    <bold>H</bold>
                    <sub>

                        <bold>o</bold>
                    </sub>: 
                    <sub>NAG-6SX1-1D Analyzer</sub>&#x00a0;=&#x00a0;
                    <bold>&#x03bc;</bold>
                    <sub>

                        <bold>UV-Sp.</bold>
                    </sub> (for the three alloys) which means that there is no significant difference between the means of the two methods, see 
                    <xref ref-type="fig" rid="f15">
Figure 15</xref>.</p>
                <fig fig-type="figure" id="f15" orientation="portrait" position="float">
                    <label>
Figure 15. </label>
                    <caption>
                        <title>Profile-time analysis for standard addition utilizing three distinct alloys.</title>
                    </caption>
                    <graphic id="gr15" orientation="portrait" position="float" xlink:href="https://f1000research-files.f1000.com/manuscripts/192842/5b86c20b-6d49-47fb-ba42-52586f783f86_figure15.gif"/>
                </fig>
                <p>Contrary to the alternative hypothesis: there was a significant difference between the mean of the two methods. i.e.; H
                    <sub>1: NAG-6SX1-1D Analyzer</sub>&#x00a0;=&#x00a0;&#x2260; 
                    <bold>&#x03bc;</bold>
                    <sub>

                        <bold>UV-Sp.</bold>
                    </sub> (for the three alloys respectively). The obtained results are presented in 
                    <xref ref-type="table" rid="T3">
Table 3</xref>, clearly indicates that there was no significant difference between the NAG-6SX1-1D Analyzer and UV-Spectrophotometric at the 95% confidence level (&#x03b1;&#x00a0;=&#x00a0;0.05) as the calculated t
                    <sub>cal</sub> (
                    <bold>0.263</bold>) is less than t
                    <sub>tab</sub> (
                    <bold>4.303</bold>) for the determination of Co (II) ion in different alloys.
                    <sup>
                        <xref ref-type="bibr" rid="ref29">29</xref>,
                        <xref ref-type="bibr" rid="ref30">30</xref>
                    </sup>
                </p>
            </sec>
        </sec>
        <sec id="sec17" sec-type="conclusion">
            <title>Conclusion</title>
            <p>The turbidimetric CFIA procedure can be considered as an alternative method for the analytical monitoring of Cobalt ions and its usefulness in the batch control assay can be hypothesized. The method is based on the precipitation of Co (II) ions and Nitro press in acidic medium, resulting in a pale orange product. From an experimental point of view, the application of this approach is quite simple and allows for serial testing at a rate of up to 40 samples per hour. Moreover, this method requires less expensive instruments and reagents. In this study, a quicker and more potent role determination was achieved using the NAG-6SX1-1D Analyzer with six LED as the excitation light and a UV solar cell as a detector. The standard addition technique was thus employed to reduce any potential matrix effect and obtain the maximum sensitivity, as heating or extraction procedures were not required.</p>
        </sec>
        <sec id="sec18">
            <title>Ethics and consent</title>
            <p>Ethical approval and consent were not required.</p>
        </sec>
    </body>
    <back>
        <sec id="sec21" sec-type="data-availability">
            <title>Data availability</title>
            <p>The data supporting the findings of this study are included within the article. No additional datasets were generated or analyzed during the current study.</p>
            <sec id="sec22">
                <title>Extended data</title>
                <p>This study does not include any supplementary materials such as questionnaires, interview guides, consent forms, large tables, or additional documents. So, no Extended Data is available for upload.</p>
            </sec>
        </sec>
        <ack>
            <title>Acknowledgment</title>
            <p>The authors are grateful to Prof. Dr. Issam Al-Hashimi for his efforts in collaboration with the researchers.</p>
        </ack>
        <ref-list>
            <title>References</title>
            <ref id="ref1">
                <label>1</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Genchi</surname>
                            <given-names>G</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Lauria</surname>
                            <given-names>G</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Catalano</surname>
                            <given-names>A</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Prevalence of Cobalt in the Environment and Its Role in Biological Processes.</article-title>
                    <source>

                        <italic toggle="yes">Biology.</italic>
</source>
                    <year>2023</year>;<volume>12</volume>(<issue>10</issue>):<fpage>1335</fpage>.
                    <pub-id pub-id-type="doi">10.3390/biology12101335</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref2">
                <label>2</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Rinne</surname>
                            <given-names>M</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Elomaa</surname>
                            <given-names>H</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Lundstr&#x00f6;m</surname>
                            <given-names>M</given-names>
                        </name>
</person-group>:
                    <article-title>Flowsheet design and environmental impacts of cobalt co-product recovery from complex Au-Co ores.</article-title>
                    <source>

                        <italic toggle="yes">Miner Eng.</italic>
</source>
                    <year>2023</year>;<volume>204</volume>:<fpage>108444</fpage>.
                    <pub-id pub-id-type="doi">10.1016/j.mineng.2023.108444</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref3">
                <label>3</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Hannan</surname>
                            <given-names>MA</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Hoque</surname>
                            <given-names>MM</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Hussain</surname>
                            <given-names>A</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>State-of-the-Art and Energy Management System of Lithium-Ion Batteries in Electric Vehicle Applications: Issues and Recommendations.</article-title>
                    <source>

                        <italic toggle="yes">IEEE Access.</italic>
</source>
                    <year>2018</year>;<volume>6</volume>:<fpage>19362</fpage>&#x2013;<lpage>19378</lpage>.
                    <pub-id pub-id-type="doi">10.1109/ACCESS.2018.2817655</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref4">
                <label>4</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Rachidi</surname>
                            <given-names>NR</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Nwaila</surname>
                            <given-names>GT</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Zhang</surname>
                            <given-names>SE</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Assessing cobalt supply sustainability through production forecasting and implications for green energy policies.</article-title>
                    <source>

                        <italic toggle="yes">Resour Policy.</italic>
</source>
                    <year>2021</year>;<volume>74</volume>.
                    <pub-id pub-id-type="doi">10.1016/j.resourpol.2021.102423</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref5">
                <label>5</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Zinkle</surname>
                            <given-names>SJ</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Busby</surname>
                            <given-names>JT</given-names>
                        </name>
</person-group>:
                    <article-title>Structural materials for fission &amp; fusion energy.</article-title>
                    <source>

                        <italic toggle="yes">Mater Today.</italic>
</source>
                    <year>2009</year>;<volume>12</volume>(<issue>11</issue>):<fpage>12</fpage>&#x2013;<lpage>19</lpage>.
                    <pub-id pub-id-type="doi">10.1016/S1369-7021(09)70294-9</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref6">
                <label>6</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Khan</surname>
                            <given-names>M</given-names>
                        </name>
</person-group>:
                    <article-title>Innovations in Battery Technology: Enabling the Revolution in Electric Vehicles and Energy Storage.</article-title>
                    <source>

                        <italic toggle="yes">Br J Multidiscip Adv Stud.</italic>
</source>
                    <year>2024</year>;<volume>5</volume>:<fpage>23</fpage>&#x2013;<lpage>41</lpage>.
                    <pub-id pub-id-type="doi">10.37745/bjmas.2022.0414</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref7">
                <label>7</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Deberdt</surname>
                            <given-names>R</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Le Billon</surname>
                            <given-names>P</given-names>
                        </name>
</person-group>:
                    <article-title>The green transition in context&#x2014;Cobalt responsible sourcing for battery manufacturing.</article-title>
                    <source>

                        <italic toggle="yes">Society &amp; Natural Resources.</italic>
</source>
                    <year>2022</year>;<volume>35</volume>(<issue>7</issue>):<fpage>784</fpage>&#x2013;<lpage>803</lpage>.
                    <pub-id pub-id-type="doi">10.1080/08941920.2022.2049410</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref8">
                <label>8</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Chen</surname>
                            <given-names>W</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Wang</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Dong</surname>
                            <given-names>B</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Properties and microstructural evolution of a ternary Cu&#x2013;Co&#x2013;Fe immiscible alloy solidified under high magnetic fields.</article-title>
                    <source>

                        <italic toggle="yes">J Mater Res Technol.</italic>
</source>
                    <year>2023</year>;<volume>24</volume>:<fpage>3564</fpage>&#x2013;<lpage>3574</lpage>.
                    <pub-id pub-id-type="doi">10.1016/j.jmrt.2023.04.086</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref9">
                <label>9</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Hao</surname>
                            <given-names>Z</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Zhou</surname>
                            <given-names>J</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Liu</surname>
                            <given-names>D</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Two-dimensional confinement engineering of SiO2 nanosheets supported nano-cobalt for high-efficiency microwave absorption.</article-title>
                    <source>

                        <italic toggle="yes">Chem Eng J.</italic>
</source>
                    <year>2023</year>;<volume>473</volume>:<fpage>145296</fpage>.
                    <pub-id pub-id-type="doi">10.1016/j.cej.2023.145296</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref10">
                <label>10</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Yoo</surname>
                            <given-names>E</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Samardak</surname>
                            <given-names>AY</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Jeon</surname>
                            <given-names>YS</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Composition-driven crystal structure transformation and magnetic properties of electrodeposited Co&#x2013;W alloy nanowires.</article-title>
                    <source>

                        <italic toggle="yes">J Alloys Compd.</italic>
</source>
                    <year>2020</year>;<volume>843</volume>:<fpage>155902</fpage>.
                    <pub-id pub-id-type="doi">10.1016/j.jallcom.2020.155902</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref11">
                <label>11</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Yousuf</surname>
                            <given-names>N</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Ma</surname>
                            <given-names>Y</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Mahmood</surname>
                            <given-names>Q</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Enhancing isoprene polymerization with high activity and adjustable monomer enchainment using cyclooctyl-fused iminopyridine iron precatalysts.</article-title>
                    <source>

                        <italic toggle="yes">Dalton Trans.</italic>
</source>
                    <year>2024</year>;<volume>53</volume>(<issue>2</issue>):<fpage>753</fpage>&#x2013;<lpage>764</lpage>.
                    <pub-id pub-id-type="doi">10.1039/d3dt03674j</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref12">
                <label>12</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Michelas</surname>
                            <given-names>M</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Redjel</surname>
                            <given-names>YK</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Daran</surname>
                            <given-names>J-C</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Cobalt (II) and cobalt (III) complexes of tripodal tetradentate diamino-bis (phenolate) ligands: Synthesis, characterization, crystal structures and evaluation in radical polymerization processes.</article-title>
                    <source>

                        <italic toggle="yes">Inorg Chim Acta.</italic>
</source>
                    <year>2010</year>;<volume>363</volume>:<fpage>2693</fpage>&#x2013;<lpage>2694</lpage>.
                    <pub-id pub-id-type="doi">10.1016/j.ica.2023.121408</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref13">
                <label>13</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Liu</surname>
                            <given-names>S</given-names>
                        </name>

                        <name name-style="western">
                            <surname>He</surname>
                            <given-names>Y</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Fu</surname>
                            <given-names>W</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Hetero-site cobalt catalysts for higher alcohols synthesis by CO2 hydrogenation: A review.</article-title>
                    <source>

                        <italic toggle="yes">J CO2 Util.</italic>
</source>
                    <year>2023</year>;<volume>67</volume>:<fpage>102322</fpage>.
                    <pub-id pub-id-type="doi">10.1016/j.jcou.2022.102322</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref14">
                <label>14</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>He</surname>
                            <given-names>H</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Wang</surname>
                            <given-names>Y</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Qi</surname>
                            <given-names>Y</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Review on the preparation methods and strengthening mechanisms of medium-entropy alloys with CoCrNi as the main focus.</article-title>
                    <source>

                        <italic toggle="yes">J Mater Res Technol.</italic>
</source>
                    <year>2023</year>;<volume>27</volume>:<fpage>6275</fpage>&#x2013;<lpage>6307</lpage>.
                    <pub-id pub-id-type="doi">10.1016/j.jmrt.2023.10.266</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref15">
                <label>15</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Kroc</surname>
                            <given-names>TK</given-names>
                        </name>
</person-group>:
                    <article-title>Monte Carlo simulations demonstrating physics of equivalency of gamma, electron-beam, and X-ray for radiation sterilization.</article-title>
                    <source>

                        <italic toggle="yes">Radiat Phys Chem.</italic>
</source>
                    <year>2023</year>;<volume>204</volume>.
                    <pub-id pub-id-type="doi">10.1016/j.radphyschem.2022.110702</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref16">
                <label>16</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Turkey</surname>
                            <given-names>NS</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Fares</surname>
                            <given-names>SH</given-names>
                        </name>
</person-group>:
                    <article-title>Determination of Fuconazole using flow injection analysis and turbidity measurement by a homemade NAG-4SX3-3D analyzer.</article-title>
                    <source>

                        <italic toggle="yes">Chem Methodol.</italic>
</source>
                    <year>2022</year>;<volume>6</volume>(<issue>10</issue>):<fpage>731</fpage>&#x2013;<lpage>749</lpage>.
                    <pub-id pub-id-type="doi">10.22034/chemm.2023.356013.1592</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref17">
                <label>17</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Al Awadie</surname>
                            <given-names>NST</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Yassin</surname>
                            <given-names>OA</given-names>
                        </name>
</person-group>:
                    <article-title>New method for estimation mebeverine hydrochloride drugs preparation by a new analyser: Ayah 6S.X1(WSLEDs)-T.- Two solar cells complied with C.F.I.A.</article-title>
                    <source>

                        <italic toggle="yes">Baghdad Sci J.</italic>
</source>
                    <year>2021</year>;<volume>18</volume>(<issue>3</issue>):<fpage>565</fpage>&#x2013;<lpage>574</lpage>.
                    <pub-id pub-id-type="doi">10.21123/bsj.2021.18.3.0565</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref18">
                <label>18</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Turkey</surname>
                            <given-names>NS</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Fares</surname>
                            <given-names>SH</given-names>
                        </name>
</person-group>:
                    <article-title>A novel approach for study of surface morphology &amp; roughness analysis for characterization of precipitation product at a nanoscale level via the reaction of fluconazole with phosphomolybdic acid.</article-title>
                    <source>

                        <italic toggle="yes">Chem Methodol.</italic>
</source>
                    <year>2022</year>;<volume>6</volume>(<issue>5</issue>):<fpage>385</fpage>&#x2013;<lpage>397</lpage>.
                    <pub-id pub-id-type="doi">10.22034/chemm.2022.332594.1450</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref19">
                <label>19</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Turkey</surname>
                            <given-names>NS</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Jeber</surname>
                            <given-names>JN</given-names>
                        </name>
</person-group>:
                    <article-title>Turbidimetric determination of mebeverine hydrochloride in pharmaceutical formulations using two consecutive detection zones under continuous flow conditions.</article-title>
                    <source>

                        <italic toggle="yes">Chemistry &amp; Chemical Technology.</italic>
</source>
                    <year>2022</year>;<volume>16</volume>(<issue>4</issue>):<fpage>600</fpage>&#x2013;<lpage>613</lpage>.
                    <pub-id pub-id-type="doi">10.23939/chcht16.04.600</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref20">
                <label>20</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Turkey</surname>
                            <given-names>NS</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Hussein</surname>
                            <given-names>GF</given-names>
                        </name>
</person-group>:
                    <article-title>New approach for the turbidimetric/CFIA determination of cobalt (II) ion using: 11 LEDs as a source and two solar cells at &#x00b1;90&#x00b0; for cell A and/or 6 LEDs and one detector for cell B.</article-title>
                    <source>

                        <italic toggle="yes">Int J Pharm Res.</italic>
</source>
                    <year>2021</year>;<volume>13</volume>.
                    <pub-id pub-id-type="doi">10.31838/ijpr/2021.13.02.132</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref21">
                <label>21</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Athab</surname>
                            <given-names>MH</given-names>
                        </name>

                        <name name-style="western">
                            <surname>AL-Awadi</surname>
                            <given-names>NS</given-names>
                        </name>
</person-group>:
                    <article-title>Continuous Flow Injection-Turbidimetric Analysis for Determination of Cobalt (II) Ion in Alloys Using a Microcell with Irradiation Sources at 0&#x2013;180&#x00b0; Using a Single Solar Cell as a Detector.</article-title>
                    <source>

                        <italic toggle="yes">Baghdad Sci J.</italic>
</source>
                    <year>2025</year>;<volume>22</volume>:<fpage>3239</fpage>&#x2013;<lpage>3251</lpage>.
                    <pub-id pub-id-type="doi">10.21123/2411-7986.5076</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref22">
                <label>22</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Mohammed</surname>
                            <given-names>BS</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Turkey</surname>
                            <given-names>NS</given-names>
                        </name>
</person-group>:
                    <article-title>Determination of Cobalt (II) Ion in Various Selected Alloys via Utilizing Continuous Flow Injection Analysis (CFIA) (Nagham-Four Sources of White Snow LED Arranged in Three Rows Corresponding to Three Detectors Analyzer) (NAG-4SX3-3D) at 0&#x2013;180&#x00b0; Angle.</article-title>
                    <source>

                        <italic toggle="yes">Iraqi J Sci.</italic>
</source>
                    <year>2025</year>;<volume>66</volume>(<issue>4</issue>):<fpage>1408</fpage>&#x2013;<lpage>1427</lpage>.
                    <pub-id pub-id-type="doi">10.24996/ijs.2025.66.4.2</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref23">
                <label>23</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Shakir</surname>
                            <given-names>IMA</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Al-Awadie</surname>
                            <given-names>NST</given-names>
                        </name>
</person-group>:
                    <article-title>Spectrophotometric-continuous flow injection analysis (SCFIA) for the determination of cobalt (II) ion in river &amp; alloy samples via the use of 10,10-dimethyl 9,9-diacridinium dinitrate salt-hydrogen peroxide in alkaline medium.</article-title>
                    <source>

                        <italic toggle="yes">J Kerbala Univ.</italic>
</source>
                    <year>2013</year>;<volume>11</volume>:<fpage>244</fpage>&#x2013;<lpage>258</lpage>.
                    <comment>
                        <ext-link ext-link-type="uri" xlink:href="https://www.iraqoaj.net/iasj/article/79891">https://www.iraqoaj.net/iasj/article/79891</ext-link>
                    </comment>.</mixed-citation>
            </ref>
            <ref id="ref24">
                <label>24</label>
                <mixed-citation publication-type="book">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Su</surname>
                            <given-names>L</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Xie</surname>
                            <given-names>HS</given-names>
                        </name>
</person-group>:
                    <chapter-title>Determination of trace cobalt in water by reversed flow injection spectrophotometry.</chapter-title>
                    <source>

                        <italic toggle="yes">Advanced Materials Research.</italic>
</source>
                    <publisher-name>Trans Tech Publications, Ltd.</publisher-name>;<year>2014</year>; vols.<volume>955&#x2013;959</volume>: pp.<fpage>1276</fpage>&#x2013;<lpage>1279</lpage>.
                    <pub-id pub-id-type="doi">10.4028/www.scientific.net/AMR.955-959.1276</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref25">
                <label>25</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Ezati</surname>
                            <given-names>M</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Moinfar</surname>
                            <given-names>S</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Mohammadi</surname>
                            <given-names>S</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>A continuous sample drop flow-based microextraction method for spectrophotometric determination of cobalt with 1-(2-pyridylazo)-2-naphthol in water samples.</article-title>
                    <source>

                        <italic toggle="yes">J Anal Chem.</italic>
</source>
                    <year>2021</year>;<volume>76</volume>:<fpage>172</fpage>&#x2013;<lpage>179</lpage>.
                    <pub-id pub-id-type="doi">10.1134/S1061934821020076</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref26">
                <label>26</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Somboonsuk</surname>
                            <given-names>T</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Saetear</surname>
                            <given-names>P</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Mantim</surname>
                            <given-names>T</given-names>
                        </name>

                        <etal/>
</person-group>:
                    <article-title>Transparent cross-flow platform as chemiluminescence detection cell in cross injection analysis.</article-title>
                    <source>

                        <italic toggle="yes">Molecules.</italic>
</source>
                    <year>2023</year>;<volume>28</volume>(<issue>3</issue>):<fpage>1316</fpage>.
                    <pub-id pub-id-type="doi">10.3390/molecules28031316</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref27">
                <label>27</label>
                <mixed-citation publication-type="journal">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Hol</surname>
                            <given-names>A</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Divrikli</surname>
                            <given-names>U</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Elci</surname>
                            <given-names>L</given-names>
                        </name>
</person-group>:
                    <article-title>Determination of cobalt, nickel, and iron at trace level in natural water samples by in-column chelation-reversed phase high-performance liquid chromatography.</article-title>
                    <source>

                        <italic toggle="yes">Environ Monit Assess.</italic>
</source>
                    <year>2012</year>;<volume>184</volume>:<fpage>3469</fpage>&#x2013;<lpage>3479</lpage>.
                    <pub-id pub-id-type="doi">10.1007/s10661-011-2201-9</pub-id>
                </mixed-citation>
            </ref>
            <ref id="ref28">
                <label>28</label>
                <mixed-citation publication-type="other">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Shakir</surname>
                            <given-names>IMA</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Al-Awadie</surname>
                            <given-names>NST</given-names>
                        </name>
</person-group>:
                    <article-title>LINEAR ARRAY AYAH 6SX1-T-1D SOLAR CFI ANALYSER, patent, Central organization for standardization and Quality control, classification, G01N21/00,21, Baghdad-Iraq.</article-title>
                    <year>2014</year>.</mixed-citation>
            </ref>
            <ref id="ref29">
                <label>29</label>
                <mixed-citation publication-type="book">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Miller</surname>
                            <given-names>JC</given-names>
                        </name>

                        <name name-style="western">
                            <surname>Miller</surname>
                            <given-names>JN</given-names>
                        </name>
</person-group>:
                    <source>

                        <italic toggle="yes">Statistics for Analytical Chemistry.</italic>
</source>
                    <publisher-loc>New York</publisher-loc>:
                    <publisher-name>John Wiley and Sons</publisher-name>;
                    <edition>5th ed. </edition>
                    <ext-link ext-link-type="uri" xlink:href="https://books.google.iq/books?id=Efx77dxOC3sC">Reference Source</ext-link>
                </mixed-citation>
            </ref>
            <ref id="ref30">
                <label>30</label>
                <mixed-citation publication-type="book">
                    <person-group person-group-type="author">

                        <name name-style="western">
                            <surname>Bluman</surname>
                            <given-names>AG</given-names>
                        </name>
</person-group>:
                    <source>

                        <italic toggle="yes">Elementary Statistics.</italic>
</source>
                    <publisher-name>WCB/McGraw</publisher-name>;
                    <edition>3rd ed. </edition>
                    <year>1998</year>.
                    <ext-link ext-link-type="uri" xlink:href="https://openlibrary.org/books/OL38916260M/Elementary_Statistics">Reference Source</ext-link>
                </mixed-citation>
            </ref>
        </ref-list>
    </back>
    <sub-article article-type="reviewer-report" id="report481783">
        <front-stub>
            <article-id pub-id-type="doi">10.5256/f1000research.192842.r481783</article-id>
            <title-group>
                <article-title>Reviewer response for version 1</article-title>
            </title-group>
            <contrib-group>
                <contrib contrib-type="author">
                    <name>
                        <surname>Yenduri</surname>
                        <given-names>Suvarna</given-names>
                    </name>
                    <xref ref-type="aff" rid="r481783a1">1</xref>
                    <role>Referee</role>
                </contrib>
                <aff id="r481783a1">
                    <label>1</label>Sri Adichunchanagiri College of Pharmacy, B G Nagar, Karnataka, India</aff>
            </contrib-group>
            <author-notes>
                <fn fn-type="conflict">
                    <p>
                        <bold>Competing interests: </bold>No competing interests were disclosed.</p>
                </fn>
            </author-notes>
            <pub-date pub-type="epub">
                <day>13</day>
                <month>5</month>
                <year>2026</year>
            </pub-date>
            <permissions>
                <copyright-statement>Copyright: &#x00a9; 2026 Yenduri S</copyright-statement>
                <copyright-year>2026</copyright-year>
                <license xlink:href="https://creativecommons.org/licenses/by/4.0/">
                    <license-p>This is an open access peer review report distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
                </license>
            </permissions>
            <related-article ext-link-type="doi" id="relatedArticleReport481783" related-article-type="peer-reviewed-article" xlink:href="10.12688/f1000research.174900.1"/>
            <custom-meta-group>
                <custom-meta>
                    <meta-name>recommendation</meta-name>
                    <meta-value>reject</meta-value>
                </custom-meta>
            </custom-meta-group>
        </front-stub>
        <body>
            <p>There are many technical errors. Many validation parameters are missing especially accuracy, some precision parameters, etc.&#x00a0;</p>
            <p> 1. Novelty is insufficiently discussed.</p>
            <p> 2. Mechanism of complex formation is not convincing</p>
            <p> 3. Validation is incomplete</p>
            <p> 4. LOD, LOQ seems unrealistic</p>
            <p> 5. R2 representation seems to be error</p>
            <p> 6. NO discussion method selectivity in presence of other metals like Fe, Ni, Cu etc.</p>
            <p> 7. Many spelling and grammatical errors.</p>
            <p>Is the work clearly and accurately presented and does it cite the current literature?</p>
            <p>Partly</p>
            <p>If applicable, is the statistical analysis and its interpretation appropriate?</p>
            <p>Yes</p>
            <p>Are all the source data underlying the results available to ensure full reproducibility?</p>
            <p>Partly</p>
            <p>Is the study design appropriate and is the work technically sound?</p>
            <p>Partly</p>
            <p>Are the conclusions drawn adequately supported by the results?</p>
            <p>Partly</p>
            <p>Are sufficient details of methods and analysis provided to allow replication by others?</p>
            <p>Partly</p>
            <p>Reviewer Expertise:</p>
            <p>Pharmaceutical Analysis, Green Analytical chemistry</p>
            <p>I confirm that I have read this submission and believe that I have an appropriate level of expertise to state that I do not consider it to be of an acceptable scientific standard, for reasons outlined above.</p>
        </body>
    </sub-article>
</article>
