Could night-guards be used as a simple method to detect leached-elements from dental restorations intra-orally? A study on amalgam restorations

[version 1; peer review: 1 approved, 1 not approved]
PUBLISHED 02 Oct 2017
Author details Author details
OPEN PEER REVIEW
REVIEWER STATUS

Abstract

Background: Detection of leached-elements from dental restorations intra-orally has been a subject of prime importance in dental research. However, this is challenging as most of the present techniques have some limitations. In this study, a new simple method was proposed via using night-guards. Thus, the aim of the study was to verify if night-guards could detect leached-elements from restorations as dental amalgam.
Methods: Ten upper custom-made night-guards were fabricated for patients suffering from bruxism, who had amalgam-restorations in their upper molars. The night-guards were delivered to the patients and they were instructed to wear the night-guards during when they were asleep. After six months, the night-guards were taken from the patients to be analyzed. A new unused night-guard was fabricated from the same material to be used as a control. In the used night-guards, two areas were studied: the fitting surfaces contacting the amalgam restorations and the fitting surfaces not contacting amalgam restorations. Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray Analysis (EDXA) were used to examine the structural and elemental changes in the night-guards.  
Results: SEM of the unused night-guard revealed a homogenous structure, and the composition was carbon and oxygen, as shown using EDXA (C=88.9wt% and O=11.1wt%). By contrast, the fitting surfaces of the night-guards contacting amalgam restorations showed numerous lustrous particles. Elemental analysis of these areas showed the presence of mercury and sulfur, in addition to carbon and oxygen (Hg=21.2wt%, S=2.5wt%, C=67.1wt% and O=9.2wt%). The night-guards’ fitting surfaces not contacting amalgam restorations showed slight cracking, and the composition was carbon and oxygen (C=88.3wt% and O=11.7 wt%). 
Conclusions: Analyzing fitting surfaces of night-guards contacting dental restorations, such as amalgam, could aid in understanding the nature of leached-elements from these restorations intra-orally. However, further studies about its application upon dental-restorations other than amalgam are recommended.

Keywords

Night-guard, Amalgam, Mercury, Elemental Analysis, leached Elements

Introduction

Determination of leached-elements from dental restorations has been investigated as a result of exposure to oral conditions1. Several methods have been performed both in vitro and in vivo. Most of the in vitro techniques relied on storing specimens in surrounding media, such as distilled water or artificial saliva13. Various analytical means had been used to analyze the leached-elements, including inductively-coupled-plasma, atomic-absorption, Fourier-transform-Infrared spectroscopies and chromatographic methods1,2,4.

On the other hand, in vivo methods have been used to assess the actual situation intra-orally5. In vivo techniques have been performed either in animals or humans. Cavities are prepared in the teeth of animals, such as monkeys6, pigs7,8 or rats9, then filled by dental-restorations. The released-elements are either detected after sacrificing the animals7 or by analyzing secretory products, such as urine9 or fecal samples6.

Yet, measuring the released elements in humans may be best. Several studies quantified the excretion of mercury in urine, hair and nails of patients with dental amalgam-restorations and found a positive correlation10,11. In contrast, others did not find a correlation between mercury content in hair and amalgam-restoration, but mercury in hair has been correlated with fish consumption12. Thus, assessing the leached-elements in the oral-cavity may be more specific to eliminate other possible systemic sources. Thus, several studies examined released ions in patients’ saliva13,14. However, these ions may be affected by salivary secretions or washed out by swallowing. In addition, saliva collection and storage may be technique sensitive15. Thus, a new simple method was proposed in this study through using night-guards (polymeric occlusal-splints used to decrease bruxism and clenching teeth) in gathering leached-elements from dental-restorations.

Methods

Ten upper dental alginate impressions (Tropicalgin, Zhermack, Italy) were taken as part of routine treatment at the Dental Family Clinic (Cairo, Egypt), between February and December 2016, for ten patients suffering from bruxism, and who also had amalgam-restorations in their upper molars. This was performed after all the patients signed written informed consent forms agreeing to participate in the study. The participants were six females and four males with the following inclusion criteria: adult (>18 years), non-periodontal-affected patients suffering from bruxism, and had amalgam restoration. Medically-compromised patients were excluded. Custom-made night-guards (example shown in Figure 1) were fabricated for each patient from 2mm soft polymeric sheets (Easy-Vac-Gasket, 3A-Medes, Korea), using a vacuum forming machine (Pro-Form, Keystone, Germany). The night-guards were delivered to the patients in the clinic after one week from first visit and they were instructed to wear the night-guards when they were asleep (≈7 hours±2). Recall visits were given to the patients in the regular check-up schedule after six months. In this visit, the night-guards were taken from the patients to be analyzed. A new unused night-guard was fabricated from the same material to be used as a control.

a74db9b8-d90e-4fe3-bfc5-a6d6084bedda_figure1.gif

Figure 1. Example of custom-made night-guard.

Scanning-Electron-Microscopy (SEM) and Energy-Dispersive-X-ray-Analysis (EDXA) were used to examine structural and elemental changes in the used night-guards, and compared to the unused one. In the used night-guards, two areas were studied: the fitting surfaces contacting amalgam-restorations and the fitting surfaces not contacting amalgam-restorations. The patients’ records were used to identify teeth that had restorations. Parts from these areas of interest were cut using a scissor (Singer, Germany), mounted on coded brass stubs and sputter coated with 10Å gold platinum and observed at 20000× magnification. The SEM and EDXA (Supra40, Carl-Zeiss-NTS-GmbH, Germany) were used with an accelerating voltage of 20.0–30.0kV.

Results

The SEM of the unused night-guard revealed a homogenous structure (Figure 2), with its composition consisting of carbon and oxygen (C=88.9wt%±0.3 and O=11.1wt%±0.4; Figure 3). By contrast, the night guard surfaces contacting amalgam-restorations showed numerous lustrous particles (Figure 4). Elemental analysis of these areas showed the presence of mercury and sulfur, in addition to carbon and oxygen (Hg=21.2wt%±0.6, S=2.5wt%±0.5, C=67.1wt%±0.3 and O=9.2wt%±0.5; Figure 5). The surfaces not contacting amalgam-restorations under SEM showed slight cracking, but were still homogenous without lustrous particles (Figure 6). Their composition was carbon and oxygen (C=88.3wt%±0.6 and O=11.7wt%±0.6; Figure 7).

a74db9b8-d90e-4fe3-bfc5-a6d6084bedda_figure2.gif

Figure 2. Scanning electron micrograph of an unused night-guard.

Magnification: 20000×.

a74db9b8-d90e-4fe3-bfc5-a6d6084bedda_figure3.gif

Figure 3. Energy-Dispersive-X-ray-Analysis of an unused night-guard.

a74db9b8-d90e-4fe3-bfc5-a6d6084bedda_figure4.gif

Figure 4. Scanning electron micrograph of a night-guard surface contacting amalgam-restoration.

Magnification: 20000×. Image representative of 10 night guards.

a74db9b8-d90e-4fe3-bfc5-a6d6084bedda_figure5.gif

Figure 5. Energy-Dispersive-X-ray-Analysis of night-guard surface contacting amalgam-restoration.

a74db9b8-d90e-4fe3-bfc5-a6d6084bedda_figure6.gif

Figure 6. Scanning electron micrograph of night-guard surface not contacting amalgam-restoration, Magnification: 20000×.

Image representative of 10 night guards.

a74db9b8-d90e-4fe3-bfc5-a6d6084bedda_figure7.gif

Figure 7. Energy-Dispersive-X-ray-Analysis of night-guard surface not contacting amalgam-restoration.

Dataset 1.SEM images for night guard surfaces contacting and not contacting amalgam restorations.
Dataset 2.Raw EDXA data for night guard surfaces contacting and not contacting amalgam restorations.

Discussion

The oral-cavity is an aggressive environment, which may affect the integrity of dental restorations1618. It is essential to examine the resultant leached-elements to assess the degradation products of the filling materials in the oral-cavity and investigate if these materials could provoke an adverse systemic effect19.

Several studies have examined released elements by in vitro testing through fabricating specimens and soaking them in medium1,2,20. However, simulating the oral-cavity is difficult due to its complex nature with multifactorial variables17. Thus, some studies have analyzed patients’ saliva2123. However, saliva is composed of various components and its analysis has shown variation in methodology. In addition, contamination of saliva may occur15.

Accordingly, in this study, a new technique was introduced via examining night guards contacting dental restorations. Night guards are polymeric materials designed to fit the occlusal-surfaces of patients to decrease signs and symptoms of bruxism and teeth clenching. Consequently, the study was performed by providing patients who suffered from bruxism with custom-made night guards. An additional inclusion criterion was the presence of amalgam fillings in their upper molars. Amalgam restorations were selected rather than any other dental restoration, as it has been well proven in the literature that mercury is released from such material19. Therefore, utilizing night guards in gathering leached-elements from amalgam-restorations intra-orally was evaluated in this study.

Both the unused night guard and the used surfaces not contacting amalgam-restorations were homogenous, yet the latter showed cracking, which may be due to bruxism. This consistent structure may be attributed to the following: these areas were not contacting dental restorations and no leached elements were deposited. This was confirmed by the EDXA results, which were only carbon and oxygen in both. The night-guards are polymeric materials, with their basic structure consisting of carbon, oxygen and hydrogen24. However, hydrogen was not detected as it did not have core electron, only one valence electron that enters in chemical bonding25. Analysis relied on excitation of electrons in lower shells, not the valence electron, which was shared in covalent bonding in the case of hydrogen25.

The night guard surfaces contacting amalgam restorations showed numerous lustrous particles, which were identified by EDXA as mercury. This is in agreement with numerous studies that have detected mercury released from amalgam restorations19,26. Sulfur was also detected, which may be due to tarnish and corrosion of the amalgam27.

Since leached elements detected by night guards matched with that reported in the literature, night-guards could be used as a simple method to detect released elements from dental restorations such as amalgam intra-orally.

Data availability

Dataset 1. SEM images for night guard surfaces contacting and not contacting amalgam restorations. 10.5256/f1000research.12311.d17738328

Dataset 2. Raw EDXA data for night guard surfaces contacting and not contacting amalgam restorations. 10.5256/f1000research.12311.d17738429

Comments on this article Comments (0)

Version 1
VERSION 1 PUBLISHED 02 Oct 2017
Comment
Author details Author details
Competing interests
Grant information
Copyright
Download
 
Export To
metrics
Views Downloads
F1000Research - -
PubMed Central
Data from PMC are received and updated monthly.
- -
Citations
CITE
how to cite this article
Abdelraouf RM. Could night-guards be used as a simple method to detect leached-elements from dental restorations intra-orally? A study on amalgam restorations [version 1; peer review: 1 approved, 1 not approved]. F1000Research 2017, 6:1786 (https://doi.org/10.12688/f1000research.12311.1)
NOTE: If applicable, it is important to ensure the information in square brackets after the title is included in all citations of this article.
track
receive updates on this article
Track an article to receive email alerts on any updates to this article.

Open Peer Review

Current Reviewer Status: ?
Key to Reviewer Statuses VIEW
ApprovedThe paper is scientifically sound in its current form and only minor, if any, improvements are suggested
Approved with reservations A number of small changes, sometimes more significant revisions are required to address specific details and improve the papers academic merit.
Not approvedFundamental flaws in the paper seriously undermine the findings and conclusions
Version 1
VERSION 1
PUBLISHED 02 Oct 2017
Views
15
Cite
Reviewer Report 07 Dec 2017
Brian W. Darvell, School of Dentistry, University of Birmingham, Birmingham, UK 
Not Approved
VIEWS 15
On the face of it, the concept has some attraction, but it is predicated on something unstated: that the mouthguard material will adsorb any ions arising from the amalgam. Here we have the first problem: dissolution is not leaching, so ... Continue reading
CITE
CITE
HOW TO CITE THIS REPORT
Darvell BW. Reviewer Report For: Could night-guards be used as a simple method to detect leached-elements from dental restorations intra-orally? A study on amalgam restorations [version 1; peer review: 1 approved, 1 not approved]. F1000Research 2017, 6:1786 (https://doi.org/10.5256/f1000research.13326.r28198)
NOTE: it is important to ensure the information in square brackets after the title is included in all citations of this article.
Views
15
Cite
Reviewer Report 11 Oct 2017
Sabry A. El-Korashy, Faculty of Science, Department of Chemistry, Suez Canal University, Ismailia, Egypt 
Approved
VIEWS 15
Different methods are used in determination of the leached-elements from dental restorations intra-orally are reported. Some of these methods have been performed both in vitro and vivo, using different analytical techniques. They were carried out via surrounding media, such as ... Continue reading
CITE
CITE
HOW TO CITE THIS REPORT
El-Korashy SA. Reviewer Report For: Could night-guards be used as a simple method to detect leached-elements from dental restorations intra-orally? A study on amalgam restorations [version 1; peer review: 1 approved, 1 not approved]. F1000Research 2017, 6:1786 (https://doi.org/10.5256/f1000research.13326.r26560)
NOTE: it is important to ensure the information in square brackets after the title is included in all citations of this article.

Comments on this article Comments (0)

Version 1
VERSION 1 PUBLISHED 02 Oct 2017
Comment
Alongside their report, reviewers assign a status to the article:
Approved - the paper is scientifically sound in its current form and only minor, if any, improvements are suggested
Approved with reservations - A number of small changes, sometimes more significant revisions are required to address specific details and improve the papers academic merit.
Not approved - fundamental flaws in the paper seriously undermine the findings and conclusions
Sign In
If you've forgotten your password, please enter your email address below and we'll send you instructions on how to reset your password.

The email address should be the one you originally registered with F1000.

Email address not valid, please try again

You registered with F1000 via Google, so we cannot reset your password.

To sign in, please click here.

If you still need help with your Google account password, please click here.

You registered with F1000 via Facebook, so we cannot reset your password.

To sign in, please click here.

If you still need help with your Facebook account password, please click here.

Code not correct, please try again
Email us for further assistance.
Server error, please try again.