Keywords
umbilical cord; prolapse; obstetric; neonatal
umbilical cord; prolapse; obstetric; neonatal
Umbilical cord prolapse (UCP) is the abnormal descent of the umbilical cord through the cervix or past the presenting part in the presence of ruptured membrane. The overall incidence of UCP ranges from 0.1-0.6 %.1 It is an infrequent and unpredictable obstetric emergency.2 It occurs more commonly in pregnancies with amniotic membrane rupture before labour.3 Delay of management is responsible for poor perinatal outcome.2 Therefore, timely recognition and intervention is needed to avoid neonatal morbidity and mortality.4 The cord prolapse to delivery time and delay in transfer to hospital are associated with unfavourable neonatal outcome.5
Here, we present a case of 28-year multigravida of term pregnancy with cord prolapse of seven hours following rupture of membrane, who underwent an emergency caesarean section with good neonatal outcome. She was a referred case from a peripheral rural health centre.
A 28-year old Nepalese female, Hindu by religion and housewife with gravida four, parity one and living one at 38 weeks 6 days of gestation, a referred case from district level hospital, presented to our tertiary care centre with a diagnosis of premature rupture of membrane of 15 hours and cord prolapse of seven hours. She was well 15 hours before when she experienced vaginal leaking, not associated with pain in the abdomen. There was no history of fever or foul-smelling vaginal discharge. Her past four deliveries were uneventful.
On physical examination by the attending obstetrician, her uterus was of term size with longitudinal lie, cephalic presentation and the fetal head was free. There was no uterine contraction. The fetal heart rate as heard by fetal doppler was 150 beats per minute and was regular. On speculum examination, a glistening white structure was seen lying in the vagina as shown in Figure 1. Thus, the diagnosis of cord prolapse was confirmed. Complete blood count, C-reactive protein, urine routine/microscopic examination and high vaginal swab analyses were conducted.
On vaginal examination, the umbilical cord hanging by the side of the presenting part was wrapped with a gauze soaked with warm saline. One of the assistants wearing sterile glove placed a hand inside the patient’s vagina and lifted the presenting part. At the same time, the assistant palpated the cord and confirmed its presence by feeling pulsation of umbilical arteries. Then, Foley’s catheterization was done and approximately 200 ml of distilled water was infused into the urinary bladder. The patient was immediately taken to the operation theatre on trolley in exaggerated Sims position. Emergency caesarean section was then done. Intra-operative findings were that the placenta had already separated with retroplacental clots of 100 ml. Baby was cephalic, left occipito-anterior and placenta was in fundo-anterior position.
The outcome of caesarean section was a single alive male baby with birth weight of 3300 grams, cried immediately after delivery with Apgar score of 6/10 and 8/10 at one and five minutes respectively. The weight of placenta was 550 grams.
On second and third day postpartum, the patient had a few episodes of fever of maximum 102° F for which fever panel was sent and all came out to be within normal limits. She was kept under intravenous antibiotics for 48 hours (intravenous ceftriaxone 1 g 12 hourly and intravenous metronidazole 500 mg 8 hourly). C-reactive protein of baby was also sent for testing and came out to be negative. Patient was discharged on fifth day post-operative with afebrile period of > 24 hours and was followed up on seventh day for suture removal. Both mother and baby were fine.
UCP is a rare occurrence, and very little literature has reported on long duration of UCP. Incidence of cord prolapse ranges from one to six per 1000 pregnancies, and it is associated with high perinatal mortality, ranging from 23% to 27% in low-income countries and 6% to 10% in high-income countries.2 Risk factors for UCP include fetal malpresentation, fetal prematurity, multifetal gestation, polyhydramnios and spontaneous rupture of membrane.3 In our case, the associated risk factor was spontaneous rupture of membrane when the head was not engaged.
In a study by Lin MG et al., perinatal mortality was found to be significantly greater when prolapse occurred outside the hospital (38-40%) compared to within hospital (0-3%).6 Due to neonatal morbidity and mortality associated with UCP, rapid and decisive management is required. The guiding principle was to deliver the fetus as soon as possible. Cesarean section is the recommended mode of delivery.1
In a study by Li PC et al., they delivered a baby vaginally after 30 minutes of UCP, whereas in our case, we did a caesarean section.4 It is reported that the outcome of umbilical cord prolapse is good, if the baby is delivered within a half hour of diagnosis.5 However, in our case even after seven hours of cord prolapse, the neonatal outcome was good.
In a study by Murphy DJ et al., the authors concluded that Apgar scores were better with a shorter DDI (diagnosis of UCP to delivery interval) and babies delivered vaginally generally had shorter DDIs and better Apgar scores than those delivered through caesarean section.7 However, in our case, even though DDI was longer and the patient underwent a caesarean section, the baby was delivered with a good Apgar score.
One limitation of our study was that we lost to follow up the case on a long-term basis. In this case, we learned that the situation was very urgent and required immediate management. After the rupture of membrane, it is mandatory to do per vaginal examination to rule out cord prolapse. These types of cases need to be urgently referred from peripheral health centres to well-equipped hospitals early so that timely definitive management can be done.
The umbilical cord prolapse should be ruled out in a term pregnant woman presenting with ruptured membrane or persistent per vaginal discharge. These cases need to be recognized and managed as early as possible. They should be urgently referred to a well-equipped centre, where caesarean delivery service is available.
All data underlying the results are available as part of the article and no additional source data are required.
Written informed consent for publication of the clinical details and clinical image has been obtained from the patient.
Views | Downloads | |
---|---|---|
F1000Research | - | - |
PubMed Central
Data from PMC are received and updated monthly.
|
- | - |
Is the background of the case’s history and progression described in sufficient detail?
Partly
Are enough details provided of any physical examination and diagnostic tests, treatment given and outcomes?
Partly
Is sufficient discussion included of the importance of the findings and their relevance to future understanding of disease processes, diagnosis or treatment?
Partly
Is the case presented with sufficient detail to be useful for other practitioners?
Partly
Competing Interests: No competing interests were disclosed.
Reviewer Expertise: I am a Maternal Fetal Medicine subspecialist and have rewritten a review of the diagnosis and management of umbilical cord prolapse
Is the background of the case’s history and progression described in sufficient detail?
Yes
Are enough details provided of any physical examination and diagnostic tests, treatment given and outcomes?
Yes
Is sufficient discussion included of the importance of the findings and their relevance to future understanding of disease processes, diagnosis or treatment?
Yes
Is the case presented with sufficient detail to be useful for other practitioners?
Yes
Competing Interests: No competing interests were disclosed.
Reviewer Expertise: Obstetrics Gynecology Infertility
Alongside their report, reviewers assign a status to the article:
Invited Reviewers | ||
---|---|---|
1 | 2 | |
Version 1 17 Aug 22 |
read | read |
Provide sufficient details of any financial or non-financial competing interests to enable users to assess whether your comments might lead a reasonable person to question your impartiality. Consider the following examples, but note that this is not an exhaustive list:
Sign up for content alerts and receive a weekly or monthly email with all newly published articles
Already registered? Sign in
The email address should be the one you originally registered with F1000.
You registered with F1000 via Google, so we cannot reset your password.
To sign in, please click here.
If you still need help with your Google account password, please click here.
You registered with F1000 via Facebook, so we cannot reset your password.
To sign in, please click here.
If you still need help with your Facebook account password, please click here.
If your email address is registered with us, we will email you instructions to reset your password.
If you think you should have received this email but it has not arrived, please check your spam filters and/or contact for further assistance.
Comments on this article Comments (0)