Abstract

Venous thromboembolic disease is associated with high rates of morbidity and mortality. First line therapy for thromboembolic disease remains anticoagulation. However, certain populations warrant consideration of an inferior vena cava (IVC) filter. This case report discusses an example of a patient who presented with an acute pulmonary embolism and highlights the utilization of the inferior vena cava (IVC) filter as patient therapy. Thus, in this case report we will review the indications for IVC filter placement and compare the compliance of IVC filter placement to established guidelines of use.

Keywords

Inferior Vena Cava Filter, Venous Thromboembolic Disease

Introduction

Pulmonary embolism (PE) and deep vein thrombosis (DVT), collectively known as venous thromboembolism (VTE), remain significant clinical problems in the United States and are responsible for over 250,000 hospitalizations and 50,000 deaths per year in the U.S. alone4. In light of this, standard therapies of care have been established in managing VTEs. First line therapy in the management of VTE is anticoagulation. However, anticoagulation may often be contraindicated including in patients at an increased bleeding risk. In these patients, an alternative approach has been recommended via the interruption of the inferior vena cava (IVC). This case report will demonstrate an example of the use of the IVC filter as well as review the guidelines for IVC filter placement when systemic anticoagulation cannot be utilized.

Case

A 46-year-old woman presented with one week of worsening shortness of breath and sub-sternal chest pain. She also noted swelling of her bilateral lower extremities, but denied recent travel, smoking, or use of oral contraceptives. Past medical history was significant for a first trimester miscarriage 15 years prior. Heart rate was 104 and other vital signs were normal. There was a systolic murmur at the left-upper sternal border and trace bilateral lower extremity edema. Hemoglobin was 10.2 g/dL, with a normal MCV, and a pro-BNP was 5415 pg/mL. EKG revealed tachycardia with evidence of right heart strain in a S1Q3T3 pattern. A V/Q scan demonstrated extensive bilateral pulmonary emboli, with a possible saddle embolus and an echocardiogram showed right ventricular dilation and moderate to severe tricuspid valve regurgitation. Lower extremity dopplers revealed extensive left lower extremity thrombus from the femoral to the external iliac vein. The patient was started on low molecular weight heparin at a dose of 1mg/kg every 12 hours and an IVC filter was placed given the substantial clot burden. Evaluation for a hypercoagulable state including factor V Leiden deficiency and a comprehensive antiphospholipid profile were unremarkable. Follow-up lower extremity dopplers three months later revealed improvement of thrombus in the evaluated veins including the peroneal, common femoral, and external iliac veins. A repeat echocardiogram six months later showed resolution of right heart strain pathology. The patient followed up with the hematology department and the decision was made to continue the patient on life-long anticoagulation in the setting of an unprovoked venous thromboembolism. The patient also followed up with the radiology department about eight months after filter insertion, but given the time that had lapsed since it was inserted and the increased difficulty of extraction, the filter was not removed at that time.

Discussion

Venous thromboembolic disease remains a significant clinical problem in the United States with mortality rates reaching as high as 30% for pulmonary embolism alone if left untreated5. While first line treatment for venous thromboembolic events remains systemic anticoagulation, certain populations warrant consideration of an inferior vena cava (IVC) filter. The American College of Chest Physicians (ACCP) and the Society of Interventional Radiology (SIR) recommend IVC filters in patients at an increased bleeding risk who are unable to tolerate systemic anticoagulation. The SIR extends IVC filter use to patients with free-floating proximal DVTs, massive PE treated with thrombolysis/thrombectomy, chronic PE treated with thromboendarterectomy, VTE with limited cardiopulmonary reserve, poor compliance to anticoagulant medications, high risk of complication of anticoagulation such as frequent falls, and as in our patient, ileocaval DVTs. The SIR also recommends IVC filter use for prophylaxis in patients with a hypercoagulable state, during periods of immobilization such as after trauma, or in surgical patients who cannot tolerate systemic anticoagulation2. Given these recommendations, IVC filter placement is becoming increasingly common with a 25-fold increase in the use of IVC filters from 1979 to 20096. Currently 58% of new filters are placed solely for prophylactic use6.

With the surge in utilization of IVC filters, it is crucial to ascertain the efficacy of IVC filters in preventing pulmonary embolism. Data shows incidence rates of PE to be as low as 2–4% following filter placement3. However, much of the data is collected from retrospective systematic reviews and does not compare IVC filter use to anticoagulation. In a randomized controlled trial of the efficacy of IVC filters combined with anticoagulation compared to anticoagulation alone, there was no statistically significant difference in the incidence rate of PE, suggesting that IVC filters offer no additional benefit if anticoagulation can be tolerated3. There are also no large randomized control trials comparing the efficacy of IVC filter placement as a prophylactic measure, despite increasing use for this indication. In addition, several retrospective studies have assessed the compliance of IVC filter placement with accepted standards. Approximately 80% of IVC filter placements met SIR guidelines, whereas only 40% met ACCP guidelines1. In our case, IVC filter placement only met SIR guidelines.

Several severe complications including increased risk of DVTs (5.4%), vena cava obstruction (2.8%), filter migration (1.3%), filter fracture, and vena cava perforation have all been affiliated with IVC filter use6. The use of an IVC filter for greater than 30 days was associated with an increased risk of all complications. However, rates of removal of retrievable IVC filters ranged as low as 12% to 45%6. In summation, with the increased utilization of IVC filters, the low rates of compliance to accepted guidelines, the low rates of removal of IVC filters, and the potential for serious complications it is crucial for clinicians to be aware of current guidelines for filter placement and understand their efficacy. With this knowledge, clinicians will be able to make an informed decision on when to appropriately utilize the inferior vena cava as patient therapy.

Consent

Written informed consent for publication of their clinical details was obtained from the patient.

Comments on this article Comments (0)

Version 1
VERSION 1 PUBLISHED 03 May 2016
Comment
Author details Author details
Competing interests
Grant information
Copyright
Download
 
Export To
metrics
Views Downloads
F1000Research - -
PubMed Central
Data from PMC are received and updated monthly.
- -
Citations
CITE
how to cite this article
Khan H and Jilani U. Case Report: Filtering the data on IVC filters [version 1; peer review: peer review discontinued]. F1000Research 2016, 5:795 (https://doi.org/10.12688/f1000research.8198.1)
NOTE: If applicable, it is important to ensure the information in square brackets after the title is included in all citations of this article.
track
receive updates on this article
Track an article to receive email alerts on any updates to this article.

Peer review discontinued

Peer review at F1000Research is author-driven. Currently no reviewers are being invited. What does this mean?

Comments on this article Comments (0)

Version 1
VERSION 1 PUBLISHED 03 May 2016
Comment
Alongside their report, reviewers assign a status to the article:
Approved - the paper is scientifically sound in its current form and only minor, if any, improvements are suggested
Approved with reservations - A number of small changes, sometimes more significant revisions are required to address specific details and improve the papers academic merit.
Not approved - fundamental flaws in the paper seriously undermine the findings and conclusions
Sign In
If you've forgotten your password, please enter your email address below and we'll send you instructions on how to reset your password.

The email address should be the one you originally registered with F1000.

Email address not valid, please try again

You registered with F1000 via Google, so we cannot reset your password.

To sign in, please click here.

If you still need help with your Google account password, please click here.

You registered with F1000 via Facebook, so we cannot reset your password.

To sign in, please click here.

If you still need help with your Facebook account password, please click here.

Code not correct, please try again
Email us for further assistance.
Server error, please try again.