Keywords
Endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty, inverted lenticule, graft adhesion, primary graft failure
This article is included in the Eye Health gateway.
Endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty, inverted lenticule, graft adhesion, primary graft failure
The advent of endothelial keratoplasties has revolutionised the treatment of corneal endothelial disorders and has enabled the restoration of a near normal corneal anatomy and physiology.1,2 Also, the complications associated with a conventional penetrating keratoplasty (PK) such as suture related infections, vascularization and risks of an open sky procedure are drastically decreased with these lamellar surgeries.1,2 However, these procedures are not completely risk free and suboptimal results can ensue from graft detachment, rejection, chronic endothelial attrition, etc.1,3 Primary graft failure is one such complication that can occur following Descemet stripping automated endothelial keratoplasty (DSAEK) and is defined as corneal stromal edema which does not clear despite the presence of a well apposed graft.1,3 A donor graft with decreased endothelial count or loss of endothelial cells due to traumatic surgical manoeuvring are the most common causes of primary graft failure. This intraoperative manipulation of the graft is done primarily to ensure the correct orientation of the lenticule. Although several approaches exist to facilitate the same, it may still get attached in an inverted fashion, especially with very thin lenticules or in eyes with significant corneal scarring.4,5 Insertion of an inverted graft has not been reported as a cause of primary failure and so this report intends to describe the clinical features and management of primary graft failure in an eye with an attached yet reversed DSAEK lenticule.
A 66-year-old gentleman had complaints of intermittent pain and watering in the right eye after having undergone a small incision cataract surgery with a posterior chamber intraocular lens twelve years before presenting to us. This complaint had exaggerated in the three months prior to presentation and was now associated with a decrease in vision. There was no past history of any prior interventions, and the patient did not give any relevant family history. At presentation, his visual acuity in the right eye was counting fingers, while that in the left eye was 20/25. Slit lamp examination revealed an edematous cornea with epithelial bullae in the periphery (Figure 1). The anterior chamber was hazily seen and appeared normal with a stable intraocular lens. The posterior segment was hazily visible and revealed no abnormalities. The left eye had a visual acuity of 20/20 with a clear cornea and no guttate changes. A cataractous lens was present. Rest of the anterior and posterior segment examination was within normal limits. Specular microscopic examination revealed a healthy endothelial morphology and count in the left eye. A diagnosis of pseudophakic bullous keratopathy was made and the patient was planned for a DSAEK.
(C, D) Image captured one month after the Descemet stripping automated endothelial keratoplasty (DSAEK) showing primary graft failure with a well attached graft. (E, F) Clear cornea with a attached DSAEK lenticule 2 weeks after the repeat endothelial keratoplasty.
The surgery was carried out under local anesthesia and followed a standard technique.6–8 Briefly, the central 9 mm of the host Descemet’s membrane was stripped. An 8mm trephination was carried out on a pre-cut donor tissue with an endothelial count of 2508 cells/mm2. The graft was inserted with a Sheets glide and apposed to the host stroma with a full chamber air tamponade of ten minutes. Postoperatively the visual acuity was counting fingers and the graft was edematous but well attached on the optical coherence tomography (OCT) scan (Figure 1). The patient was started on topical corticosteroids (prednisolone acetate 1%, six times/day) and antibiotics (moxifloxacin 0.5%, 4 times/day). The patient was reviewed again after three weeks and no improvement in either the visual acuity or the corneal clarity was noted. The OCT was repeated and the graft edge was included in the scan which showed a reversed orientation of the graft with the longer endothelial side adherent to the stroma (Figure 2). Furthermore, the irregular donor stromal surface facing the anterior chamber was also observed (Figure 2).
The patient underwent a repeat DSAEK, 6 weeks after the primary surgery. After the previous donor tissue was detached and removed, a new DSAEK lenticule, 7.5 mm in diameter, with an endothelial count of 2457 cells/mm2 was inserted. The rest of the surgical technique was similar to that of the first procedure. On the first postoperative day, the patient had a visual acuity of 20/60 with a well attached graft and a significant decrease in the corneal edema. The correct apposition and orientation of the graft was confirmed on OCT (Figure 2). The patient was continued on topical antibiotics and a tapering dose of topical corticosteroids. At the 7th month postoperative visit, the corrected visual acuity was 20/40 in the right eye. The cornea was clear with an attached lenticule, and the patient was maintained on a once daily dose of topical steroids (Figure 1). Figure 3 details the timeline of the patient from presentation to the last follow up.
SICS: small incision cataract surgery, PCIOL: posterior chamber interocular lens, DSAEK: Descemet stripping automated endothelial keratoplasty, OCT: optical coherence tomography, VA: visual acuity.
Several studies have investigated the factors that affect graft attachment following a DSAEK.5,9,10 One of the key elements that facilitates good adherence of the lenticule is the endothelial pump action.9 A well-functioning endothelium also helps to clear the corneal edema. Hence primary graft failure and graft detachment is observed in eyes with a poor quality donor tissue or excessive intraoperative manipulation.1,3 Dislocation of the graft in such cases is probably mediated by the presence of fluid in the interface, which the dysfunctional endothelium is unable to overcome. And so, various modifications of the DSAEK technique have been employed which provide an additional means for graft apposition until the functional pumps can take over. These include surface massage to displace the interface fluid, use of venting incisions and roughening of peripheral stromal fibers to create stronger adhesions.5,9,10
The use of air tamponade and increase in intraocular pressure (IOP) has also been described for the same purpose. Vaddavalli et al and Bhogal et al independently studied the role of IOP in graft adherence.5,10 Both studies did not find a significant correlation between the two although Vaddavalli et al found an increasing rate of graft attachment with higher IOP. However, the experimental set up was devised to test the attachment under normal and high pressures and the role of hypotony was not assessed. Thus, IOP probably significantly contributes to good attachment of the donor lenticule as seen in the current case where a well attached graft was seen despite its inverted position. This also highlights the fact that there may be several other factors besides the endothelial pump action which bring about the binding of the two stromal surfaces. This needs to be taken into consideration especially in eyes which have a higher rate of graft dislocation such as aphakic eyes, vitrectomised eyes or eyes with glaucoma filtering surgery.1,3 Ensuring a watertight globe at the end of the surgical procedure will help prevent postoperative hypotony and decrease the risk of graft detachment.
Primary graft failure is a rare complication following DSAEK, with a reported rate of around 1%.3 The diagnosis of this entity is made in the presence of persistent corneal edema following a DSAEK. The normal time taken for the recovery of graft clarity following DSAEK ranges from three weeks to three months which can cause a delay in establishing the diagnosis of primary failure.3 As a result, the subsequent interventions required to visually rehabilitate the patient will also get stalled. However, a reversed lenticule is an exception to this as it can be detected in the early postoperative period and promptly managed. Several measures have been advocated to help ensure the insertion and attachment of the graft in its correct position. These include marking of the stromal surface, use of the double ring sign, intraoperative OCT, etc.4,11 However, the lenticule may get inverted despite these safeguards especially in cases with very thin grafts or in eyes with suboptimal clarity of the anterior chamber structures due to corneal scarring.
As highlighted by the current case, judicious use of an OCT in the weeks following the surgery can help identify the improper orientation of the lenticule in eyes with slow recession of corneal edema. Although documentation of an attached lenticule with an AS-OCT scan is a routine practice following endothelial keratoplasty, it is essential to include the peripheral graft area when capturing such images. An acute angle configuration of the graft edge has been described which indicates a stroma-to-stroma apposition with correct positioning of the endothelial layer.4 This additional information is vital as the mere presence of an attached lenticule does not signify its correct orientation.
The current report highlights a reversed DSAEK lenticule as a cause of primary graft failure. This clinical entity can be diagnosed early with the help of an AS-OCT in eyes with slow resolution of the corneal edema and a repeat intervention can be planned subsequently. Adhesion of the graft in DSAEK may depend on factors beyond functional endothelial pumps and an improved understanding of the same will help improve outcomes in eyes which are at a greater risk of having graft detachments.
All data underlying the results are available as part of the article and no additional source data is required
Written informed consent was obtained from the patient for publication of this case report and accompanying images.
SYB contributed to the study conceptualization, study investigation, methodology, manuscript editing and revision. AK contributed to the original draft preparation, study methodology and revisions.
Views | Downloads | |
---|---|---|
F1000Research | - | - |
PubMed Central
Data from PMC are received and updated monthly.
|
- | - |
Is the background of the case’s history and progression described in sufficient detail?
Yes
Are enough details provided of any physical examination and diagnostic tests, treatment given and outcomes?
Yes
Is sufficient discussion included of the importance of the findings and their relevance to future understanding of disease processes, diagnosis or treatment?
Yes
Is the case presented with sufficient detail to be useful for other practitioners?
Yes
Competing Interests: No competing interests were disclosed.
Reviewer Expertise: Cornea, Corneal Transplant.
Is the background of the case’s history and progression described in sufficient detail?
Yes
Are enough details provided of any physical examination and diagnostic tests, treatment given and outcomes?
Yes
Is sufficient discussion included of the importance of the findings and their relevance to future understanding of disease processes, diagnosis or treatment?
Yes
Is the case presented with sufficient detail to be useful for other practitioners?
Yes
Competing Interests: No competing interests were disclosed.
Reviewer Expertise: Ophthalmology
Is the background of the case’s history and progression described in sufficient detail?
Yes
Are enough details provided of any physical examination and diagnostic tests, treatment given and outcomes?
Yes
Is sufficient discussion included of the importance of the findings and their relevance to future understanding of disease processes, diagnosis or treatment?
Yes
Is the case presented with sufficient detail to be useful for other practitioners?
Yes
Competing Interests: No competing interests were disclosed.
Reviewer Expertise: Cornea
Alongside their report, reviewers assign a status to the article:
Invited Reviewers | |||
---|---|---|---|
1 | 2 | 3 | |
Version 2 (revision) 06 Jan 23 |
|||
Version 1 27 Sep 22 |
read | read | read |
Provide sufficient details of any financial or non-financial competing interests to enable users to assess whether your comments might lead a reasonable person to question your impartiality. Consider the following examples, but note that this is not an exhaustive list:
Sign up for content alerts and receive a weekly or monthly email with all newly published articles
Already registered? Sign in
The email address should be the one you originally registered with F1000.
You registered with F1000 via Google, so we cannot reset your password.
To sign in, please click here.
If you still need help with your Google account password, please click here.
You registered with F1000 via Facebook, so we cannot reset your password.
To sign in, please click here.
If you still need help with your Facebook account password, please click here.
If your email address is registered with us, we will email you instructions to reset your password.
If you think you should have received this email but it has not arrived, please check your spam filters and/or contact for further assistance.
Comments on this article Comments (0)