Keywords
restorative resin, microhardness, surface roughness, in-office bleaching
This article is included in the Manipal Academy of Higher Education gateway.
restorative resin, microhardness, surface roughness, in-office bleaching
We have revised the abstract, introduction with updated literature, details on sample size estimation and sample preparation, added additional details in table (t-value and Inter-group P-values), additional details in ANCOVA (f-value, degrees of freedom and 95% CI) and revised the conclusion. Limitations and scope for future research were also added added in the end.
See the authors' detailed response to the review by Rama Krishna Alla
See the authors' detailed response to the review by Olivia A. Osiro
Bleaching removes intrinsic and extrinsic stains from the dental tissues.1,2 This procedure involves diffusion of bleaching agent which alters the structure of chromophore molecules present in enamel and dentin , thereby promoting tooth whitening. The outcome of tooth whitening depends on the concentration and the ability of the bleaching agent to reach the chromophore molecules coupled with duration and frequency of contact.
The most commonly used bleaching agents are hydrogen peroxide and carbamide peroxide.3 These bleaching agents can be applied at-home and in-office and are considered to be effective and relatively safe when supervised by a dentist.4 Although, bleaching is effective in improving esthetics, there has been a growing concern in the recent past on the effect of bleaching materials and techniques on existing restorative materials in the oral cavity. With greater demand for esthetics, there has been an increase in the use of direct esthetic restorative materials, especially dental composites. A dental composite restorative material mainly consists of a polymerizable resin matrix, reinforcing fillers, and a coupling agent that bonds resin with the fillers. The vast majority of dental composites are commercially available for clinical use mainly differ in terms of the resin matrix materials and the fillers used. The clinical performance of these materials significantly varies depending on the type, size, distribution, and concentration of fillers used in the composites.
Ceram.x® SphereTEC™ one (Dentsply, Konstanz, Germany) is a light-curable nanohybrid composite consisting of nanometer and micrometer-sized fillers with a granulated filler technology (SphereTEC™). It consists of a blend of pre-polymerized fillers of a size equivalent to 15 μm, non-agglomerated glass of 0.6 μm, and Ytterbium fluoride of 0.6 μm. It has distinctive handling characteristics, natural-looking gloss, and effortless polishing. Its resin matrix consists of a reformed version of the polysiloxane comprising matrix from the original Ceram.x® mono+/duo+. It is combined with a well-established polyurethane methacrylate, bis-EMA, and TEGDMA to increase its mechanical strength.
Filtek™ Z350 XT (3M, ESPE, St. Paul, USA) is a universal nanocomposite consisting nanometer-sized filler particles in the composite matrix. The nanofillers consist of 20 nm silica and 4–11 nm zirconia, both in combination of non-agglomerated/non-aggregated and aggregated forms. The presence of nanofillers in agglomerated or clustered forms with a broad distribution in the size of the clusters permits higher filler loading as well as superior polishing ability and thus the esthetic characteristics. Both Ceram.x® SphereTEC™ one and Filtek™ Z350 XT contain fillers in the nanometer range; however, their particle size and distribution is different.
Many studies have reported the action of bleaching agents on restorative materials.5–9 The observed changes after bleaching of composite resin materials are alterations in smoothness, hardness and reduction in bond strength.10,11 Despite extensive research, the observed changes among the composites seem to be varying which could be attributed to the differences in the concentration and type of bleaching agent used. In general, low concentrations of bleaching agent is used for longer times in home bleaching whereas in-office bleaching higher concentration of bleaching agent is used for shorter duration. In addition, compositional variations among dental composites such as type of resin matrix, ratio between resin matrix and filler may influence their susceptibility to bleaching.9,12 In view of constant surge of newer dental composites with myriad of variation in the composition, it is essential to investigate the effect of bleaching on the properties of composites. In this regard, the present study aimed to compare the surface roughness and microhardness of nanofilled and nanohybrid composite restorative materials subjected to in-office bleaching.
Sample size was estimated based on the microhardness values reported by Sharafeddin and Jamalipour5 which yielded an effect size of 1.42. With a power of 80% and 95% confidence interval, the sample size was estimated to be nine per group.
Twenty samples were prepared from each composite material; Ceram.x® SphereTEC™ one (Dentsply, Sirona) and Filtek Z350 XT (3M ESPE, St. Paul, USA) using a customized stainless steel split mold of 10 mm diameter and 2 mm height. Table 1 summarizes information regarding the composition and manufacturers’ details of composite resin materials.
After the composite material was packed into the mold, mylar strip (SS White Co, Philadelphia, PA, USA) was used both on top and bottom surfaces to obtain a smooth surface on the composite. Subsequently, the composite material was cured for 20 seconds on both sides using a visible light curing unit (3M ESPE Elipar, St Paul, MN, USA) having a light intensity of 1200 wM/cm2.
The prepared discs were subjected to 0.1 ml of 35% hydrogen peroxide (Pola office, SDI Limited, Australia) for 15 mins followed by two additional applications in the same session. The discs were rinsed with distilled water for one minute between each application. The same protocol was repeated two times with one week interval between the applications. After the bleaching process, all the discs were washed and stored in distilled water at 37°C.
The surface hardness of the discs before and after the bleaching was measured using the Vickers hardness testing machine (MMT X7, Matsuzawa Company, Japan). The specimens were mounted on a platform of the device, and a load of 200 g was applied for 30 seconds. The load was removed after dwell time, and the length of the diagonal of the indentation was measured from which the area of the indentation was calculated. Three measurements of each sample were carried out. The surface hardness was calculated by dividing the load by the area of the indention and was reported as Vickers hardness number (VHN).
Surface roughness of the specimens pre- and post-bleaching was measured using a surface profilometer (Surtronics 3+, Taylor Hobson, UK). The samples were placed on a flat stable surface. The stylus of the profilometer was passed over the surface of the specimen to a distance of 0.8 mm. The experiment was carried out in triplicate on each disc, and average surface roughness, as Ra, was recorded in microns.
All the analyses were done using SPSS version 20 (RRID:SCR_019096). A p-value of < 0.05 was considered statistically significant. Normality was tested using the Kolmogorov Smirnov test. Comparison of mean surface roughness and microhardness before and after the bleaching was done using the Paired t-test. ANCOVA was used to evaluate the significant differences in the surface roughness and microhardness between the materials after adjusting the baseline values. Data for this study can be accessed at Mendeley Data.13
There was no significant difference in mean microhardness before and after bleaching (p = 0.954) in Ceram.x® SphereTEC™ one. However, Filtek Z350 XT showed a significant reduction in the surface hardness after bleaching (p < 0.001). There were no significant differences in the mean surface roughness before and after bleaching in both the composite resin materials (p = 0.153 and 0.199), respectively (Table 2).
Before | After | t value | P-value† | |
---|---|---|---|---|
Mean ± SD | Mean ± SD | |||
Microhardness (VHN) | ||||
Ceram.x® SphereTEC™ one | 37.59 ± 4.28 | 37.5 ± 4.34 | 0.06 | 0.954 |
Filtek Z350 XT | 27.67 ± 2.1 | 17.83 ± 1.36 | 16.55 | <0.001* |
t | 6.59 | 13.68 | ||
P-value‡ | <0.001* | <0.001* | ||
Surface roughness (μm) | ||||
Ceram.x® SphereTEC™ one | 2.66 ± 0.26 | 2.11 ± 0.92 | 1.56 | 0.153 |
Filtek Z 350XT | 2.62 ± 0.2 | 2.52 ± 0.24 | 1.39 | 0.199 |
t | 0.4 | -1.39 | ||
P-value‡ | 0.693 | 0.194 |
ANCOVA evaluated the difference in microhardness and surface roughness between Ceram.x® SphereTEC™ one and Filtek Z350 XT after bleaching while adjusting for before bleaching values. The adjusted mean (estimated marginal mean ± SE) microhardness after bleaching for Ceram.x® SphereTEC™ one (35.79 ± 1.45 (95%CI: 32.73-38.85)) was significantly higher than Filtek Z350 XT (19.54 ± 1.45 (95%CI: 16.48-22.6)) (p < 0.001) (F (1, 17) = 40.69; p < 0.001). However, no significant difference in the adjusted mean (estimated marginal mean ± SE) surface roughness after bleaching was seen between Ceram.x® SphereTEC™ one (2.13 ± 0.2 (95%CI: 1.72-2.55)) and Filtek Z350 XT (2.5 ± 0.2 (95%CI: 2.08-2.91)) (p = 0.21) (F (1, 17) = 1.71; p = 0.21).
The main objective of the present study was to assess the effect of in-office bleaching on nanohybrid and nanofilled composites. As the bleaching process generally affects the surface characteristics of dental composites, both surface roughness and microhardness of Ceram.x® SphereTEC™ one and Filtek Z350 XT were measured prior to and after bleaching using Pola office. The active ingredient of majority of bleaching agents is hydrogen peroxide and generally oxidizes the chromophores and improves the shade of the discolored tooth. Exposure of these bleaching materials can also potentially affect the existing restorative materials due to their strong oxidizing ability.
Some of the previous investigations have reported an increase in microhardness of composites after bleaching treatment with hydrogen peroxide.14 In contrast, other research studies have indicated a reduction in surface hardness.9 Our study did not show any significant changes in the microhardness and surface roughness concerning nanohybrid composite [Ceram.x® SphereTEC™ one] which was in accordance with previous reports.15,16 There was a significant reduction in microhardness of Filtek Z350 XT, whereas the surface roughness remained unaffected. These observations were in agreement with previous research.17 An increase in the surface roughness of restorative materials will facilitate the plaque accumulation on the surface thus affecting the esthetics.18 Similarly, a decrease in the surface hardness makes the material more vulnerable to wear during masticatory force application.19
Hydrogen peroxide tends to cause oxidation, thereby facilitating the generation of free radicals.20 The unreacted double bonds in the polymer resin are prone to oxidative cleavage by peroxides. The by-products of this reaction may bring about a reduction in microhardness. Moreover, the free radicals generated by the peroxides are capable of causing hydrolytic degradation of composite resin at the resin-filler interface, thereby paving the way for filler-matrix debonding, leading to microscopic cracks and thus increasing surface roughness.21
Ceram.x® SphereTEC™ has a high proportion of filler particles with advanced granulated filler technology. The nanohybrid composition with advanced filler technology ensures a higher filler loading and hence superior flexural strength, compressive strength, and low water sorption.22 Higher filler loading and reduced resin matrix content reduces the chance of resin matrix oxidation by hydrogen peroxide, making them resilient to acidic bleaching agents. On the other hand, resin composite Filtek Z350 is a nanoparticulated composite compounded by BisGMA, UDMA, BisEMA, and minor proportions of TEGDMA. The overall inorganic filler loading in these composites is about 72% by weight, which is less than Ceram.x® SphereTEC™ composites with an inorganic filler loading of 77–79% by weight. A low filler loading with a large resin matrix volume makes these composites more prone to oxidation or degradation by bleaching agents, hence a significant reduction in microhardness after bleaching.23
Free radicals induced by peroxides may impact the resin–filler interface and cause a filler–matrix debonding.24 The microhardness of the composites is highly influenced by the amount and type of the inorganic fillers.25 Hence, a reduction in the surface microhardness for Filtek Z350 XT may be due to the inorganic filler loss on the surface. Ceram.x® SphereTEC™ one has pre-polymerized filler particles of non-agglomerated barium glass and ytterbium fluoride and a resin matrix with highly dispersed methacrylic polysiloxane nanoparticles that are chemically similar to glass or ceramics. Such filler composition is more resistant to abrasion and inorganic filler loss at the surface. Hence no significant changes in microhardness and surface roughness were observed.
The results of the present study indicate that compositional variations influence the susceptibility of dental composites to bleaching. However, the present study selected only two types of dental composites. Additional studies on large number of composites and their types (microfilled, nanofilled, hybrid composites etc.) may provide more insights on the effect of bleaching on composites restorative materials.
Within the limitations of the present study, it can be concluded that in office-bleaching with 35% hydrogen peroxide can reduce the microhardness of nanofilled composite. However, the surface roughness is not affected in both nanohybrid and nanofilled composite resin materials. Hence, the effect of the bleaching agent on the existing composite resin restorations must be considered at the time of selection of the bleaching agent and the regimen for clinical use.
Mendeley Data: Underlying data for ‘Effect of vital bleaching on surface roughness and microhardness of nanofilled and nanohybrid composite resins’, https://www.doi.org/10.17632/5fjyt8z6vc.1. 13
Data are available under the terms of the Creative Commons Attribution 4.0 International license (CC-BY 4.0).
Views | Downloads | |
---|---|---|
F1000Research | - | - |
PubMed Central
Data from PMC are received and updated monthly.
|
- | - |
Competing Interests: No competing interests were disclosed.
Reviewer Expertise: Dental Biomaterials Science
Competing Interests: No competing interests were disclosed.
Is the work clearly and accurately presented and does it cite the current literature?
Partly
Is the study design appropriate and is the work technically sound?
Yes
Are sufficient details of methods and analysis provided to allow replication by others?
Partly
If applicable, is the statistical analysis and its interpretation appropriate?
Yes
Are all the source data underlying the results available to ensure full reproducibility?
Yes
Are the conclusions drawn adequately supported by the results?
Partly
Competing Interests: No competing interests were disclosed.
Reviewer Expertise: Dental Biomaterials Science
Is the work clearly and accurately presented and does it cite the current literature?
Yes
Is the study design appropriate and is the work technically sound?
Yes
Are sufficient details of methods and analysis provided to allow replication by others?
Yes
If applicable, is the statistical analysis and its interpretation appropriate?
Yes
Are all the source data underlying the results available to ensure full reproducibility?
Yes
Are the conclusions drawn adequately supported by the results?
Yes
Competing Interests: No competing interests were disclosed.
Reviewer Expertise: Dental Materials, Nanoparticles in dentistry, fibre-reinforced composites.
Alongside their report, reviewers assign a status to the article:
Invited Reviewers | ||
---|---|---|
1 | 2 | |
Version 2 (revision) 18 May 23 |
read | read |
Version 1 02 Feb 23 |
read | read |
Provide sufficient details of any financial or non-financial competing interests to enable users to assess whether your comments might lead a reasonable person to question your impartiality. Consider the following examples, but note that this is not an exhaustive list:
Sign up for content alerts and receive a weekly or monthly email with all newly published articles
Already registered? Sign in
The email address should be the one you originally registered with F1000.
You registered with F1000 via Google, so we cannot reset your password.
To sign in, please click here.
If you still need help with your Google account password, please click here.
You registered with F1000 via Facebook, so we cannot reset your password.
To sign in, please click here.
If you still need help with your Facebook account password, please click here.
If your email address is registered with us, we will email you instructions to reset your password.
If you think you should have received this email but it has not arrived, please check your spam filters and/or contact for further assistance.
Comments on this article Comments (0)